scholarly journals District Heating System with Geothermal Energy Use in Szeged, Southern Great Plain Region, Hungary

Author(s):  
Zsolt Pinjung ◽  
János Szanyi ◽  
Balázs Kóbor ◽  
Tamás Medgyes
2020 ◽  
Vol 147 ◽  
pp. 2791-2800 ◽  
Author(s):  
Miroslav V. Kljajić ◽  
Aleksandar S. Anđelković ◽  
Vaclav Hasik ◽  
Vladimir M. Munćan ◽  
Melissa Bilec

2020 ◽  
Vol 160 ◽  
pp. 01004 ◽  
Author(s):  
Stanislav Chicherin ◽  
Lyazzat Junussova ◽  
Timur Junussov

Proper adjustment of domestic hot water (DHW) load structure can balance energy demand with the supply. Inefficiency in primary energy use prompted Omsk DH company to be a strong proponent of a flow controller at each substation. Here the return temperature is fixed to the lowest possible value and the supply temperature is solved. Thirty-five design scenarios are defined for each load deviation index with equally distributed outdoor temperature ranging from +8 for the start of a heating season towards extreme load at temperature of -26°C. All the calculation results are listed. If a flow controller is installed, the customers might find it suitable to switch to this type of DHW supply. Considering an option with direct hot water extraction as usual and a flow controller installed, the result indicates that the annual heat consumption will be lower once network temperatures during the fall or spring months are higher. The heat load profiles obtained here may be used as input for a simulation of a DH substation, including a heat pump and a tank for thermal energy storage. This design approach offers a quantitative way of sizing temperature levels in each DH system according to the listed methodology and the designer's preference.


2003 ◽  
Vol 05 (01) ◽  
pp. 83-97 ◽  
Author(s):  
FREDRIK BURSTRÖM VON MALMBORG ◽  
ANNA FORSBERG

Life cycle oriented methods are increasingly used for environmental assessments (EAs) of the built environment. However, many assumptions are made in such assessments, potentially influencing the results and making the assessment more ambiguous. To increase the reliability of EAs, consequences of the assumptions made have to be better understood. Since energy use in the operation and maintenance phase is an important factor decisive for the overall environmental performance of a building, the purpose of this study is to investigate how the selection of heat and electricity mix affects the assessed environmental performance of buildings. It also aims to suggest how to choose heat and electricity data in EAs of the built environment in general. Applying four different modes of electricity production and two different modes of heat production in a case study of three different buildings with different technical solutions for heat and electricity supply, the study show that choices of heat and electricity mix have significant influence on the final results of the EA. Regarding the choice of heat and electricity mix in an EA of buildings and the built environment, it is argued that both average and marginal data on electricity production should be used in general. As for data on district heat production, it is recommended to use data on the average production in the specific, local district heating system in general. Finally, it is argued that consequences of the assumptions made should be explicitly communicated in the EA report, so as to let the decision-makers rather than the analysts make the evaluation.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3218
Author(s):  
Pedro Durán ◽  
Herena Torio ◽  
Patrik Schönfeldt ◽  
Peter Klement ◽  
Benedikt Hanke ◽  
...  

There are 1454 district heating systems in Germany. Most of them are fossil based and with high temperature levels, which is neither efficient nor sustainable and needs to be changed for reaching the 2050 climate goals. In this paper, we present a case study for transforming a high to low temperature district heating system which is more suitable for renewable energy supply. With the Carnot Toolbox, a dynamic model of a potential district heating system is simulated and then transformed to a low temperature supply. A sensitivity analysis is carried out to see the system performance in case space constrains restrict the transformation. Finally, an economic comparison is performed. Results show that it is technically possible to perform the transformation until a very low temperature system. The use of decentralized renewable sources, decentralized heat storage tanks and the placement of a heat pump on each building are the key points to achieve the transformation. Regarding the sensitivity analysis, the transformation is worth doing until the seasonal storage and solar collector field sizes are reduced to 60% and 80% of their values in the reference case, respectively. The economic analysis shows, however, that it is hard for highly efficient low temperature renewable based heat networks to compete with district heating systems based on a centralized fossile CHP solution. Thus, though the presented transformation is technically possible, there is a strong need to change existing economic schemes and policies for fostering a stronger promotion of renewable energy policies in the heat sector.


Sign in / Sign up

Export Citation Format

Share Document