Seismic performance of Greater Jakarta LRT with added lead rubber bearing using non-linear time history analysis

Author(s):  
Iswandi Imran ◽  
Marie Hamidah ◽  
Tri Suryadi ◽  
Hasan Al-Harris ◽  
Syamsul Hidayat

<p>In order to overcome stringent seismic requirement in the new Greater Jakarta Light Rail Transit Project, a breakthrough seismic system shall be chosen to obtain expected structural performance. This seismic system shall be designed to provide operational performance level after strong earthquake events. To achieve the criteria, seismic isolation system using Lead Rubber Bearings is chosen. With this isolation system, Greater Jakarta LRT has become the first seismically isolated infrastructure and apparently an infrastructure with the largest numbers of LRBs in one single project in Indonesia. More than 10.400 Pcs LRBs are used for the first phase of the construction and the numbers will be certainly increased in the next phase of the construction. To evaluate the structural performance, non-linear time history analysis is used. A total of 3 pair matched ground motions will be used as the input for the response history analysis. The ability of the lead rubber bearing to isolate and dissipate earthquake actions will determine its structural performance level. This will be represented by the nonlinear hysteretic curves obtained throughout the earthquake actions.</p>

2019 ◽  
Vol 10 (2) ◽  
pp. 166-184
Author(s):  
Johnny Setiawan ◽  
Iswandi Imran

Terdapat cukup banyak perubahan pada SNI 1726-2012, salah satunya adalah adanya persyaratanbatas geser dasar minimum (minimum base shear) yang tidak ada pada peraturan sebelumnya.Metode yang akan dilakukan adalah bangunan gedung dengan klasifikasi ketinggian rendah,sedang dan tinggi akan dianalisis dengan menerapkan geser dasar minimum dan tanpa geser dasarminimum. Analisis yang akan digunakan adalah analisis ragam spektrum respons (ResponsSpectrum Analysis, RSA), analisis respons riwayat waktu (Time History Analysis, THA) dananalisis respons riwayat waktu non linier (Non Linear Time History Analysis, NLTHA). Hasilanalisis menunjukkan bahwa pada peraturan SNI 1726-2012 dengan adanya persyaratan batasangeser dasar minimum dapat menjamin kinerja struktur sesuai dengan yang diharapkan.Kekhawatiran adanya batasan geser dasar minimum pada SNI 1726-2012 akan membuat desainmenjadi tidak ekonomis, ternyata tidak terbukti karena tidak memberikan pengaruh signifikanpada hasil desain, khususnya untuk bangunan dengan kategori ketinggian rendah dan sedang.Untuk bangunan dengan klasifikasi bangunan tinggi, analisis dan desain dengan memperhitungansyarat batasan geser dasar minimum dan tanpa memperhitungkan geser dasar minimum dapatmemberikan hasil desain yang baik, tetapi pengecekan pada Level Kinerja (Performance Level)sesuai dengan story drift menunjukkan bahwa analisis dengan memperhitungkan syarat geser dasarminimum memberikan hasil dengan level kinerja yang cukup baik yaitu Immediate Occupancy(IO) hingga Damage Control (DO), sedangkan tanpa memperhitungkan geser dasar minimummemberikan hasil dengan level kinerja yang kurang baik yaitu Life Safety (LS) hingga StructuralStability (SS). Sedangkan pada level kinerja elemen struktur, analisis tanpa memperhitungkangeser dasar minimum menyebabkan banyak elemen struktur yang berada pada level kinerjaCollapse Prevention (CP).


Author(s):  
Tri Suryadi ◽  
Tony Sihite ◽  
Wanda Heryudiasari

<p>Structural assessment is an important procedure to be done for checking and reviewing the realization of the expected structural performance level. In a normal circumstance, it is common that the bridge is designed with life-safety performance that implies undamaged superstructures and foundations, and damaged substructures. This design philosophy is normally known as “ductile substructure and elastic superstructure” concept. The location of the damages shall be predefined to allow easy access for future repairs after earthquake events. Nowadays, a different design approach is introduced through the use of passive control devices. One of the most common technology for bridges is the seismic isolation system using sliding pendulum isolator bearing as the seismic controlling device. Ahmad Yani Continuous Span Bridge in Becakayu Toll Road Project is designed with pendulum isolator bearings. Through non-linear time history analysis, the structural performance of Ahmad Yani Bridge will be evaluated. It is expected that all the dissipation mechanism occurs in the pendulum bearings, with both superstructure and substructures are still in elastic and essentially elastic conditions.</p>


2021 ◽  
Vol 879 ◽  
pp. 232-242
Author(s):  
A.N. Refani ◽  
Yuyun Tajunnisa ◽  
K. Yudoprasetyo ◽  
F. Ghifari ◽  
D.I. Wahyudi

Indonesia is a country located in the convergence of small plates and large plates. Furthermore, this causes Indonesia to be high potentially to earthquake hazards. The newest geological research published by Geophysical Research Letter (2016) shows the existence of Fault Kendeng, a fault stretches along 300 km from South Semarang, Central Java, to East Java with a movement of 0,05 millimeter per year [1]. As a result of its research, an evaluation using a non-linear time history analysis for structural buildings is necessary. The objective of this study is to evaluate structural buildings using a non-linear time history analysis. This study applies DSHA (Deterministic Seismic Hazard Analysis) method to obtain acceleration time history on bedrocks. Since the record of ground movement in Indonesia is limited, the attenuation function equation used to scale and match other country’s time acceleration history data. SSA (Site-Specific Analysis) is used to propagate earthquake acceleration from bedrocks to the surface. The earthquake acceleration on the surface generates as the earthquake load on the buildings. The results of Kendeng fault earthquake simulation using non-linear time history analysis shows that column members capacity is more robust than beam members capacity which the beam collapse mechanism occurs initially. From the maximum total drift ratio result, when the Kendeng fault earthquake occurs, the building structure performance level is at collapse prevention level Based on ATC-40 [2]. This research result shows that 96,7% of plastic hinge has not yielded. However, some elements are already damaged. Since most damage members are column, then it may require column strengthening to enhance maximum performance level at life safety condition category.


EXTRAPOLASI ◽  
2021 ◽  
Vol 18 (1) ◽  
pp. 33-41
Author(s):  
Nurul Rochmah ◽  
Michella Beatrix ◽  
Bantot Sutriono

AbstractIndonesia is a ring of fire area where earthquakes frequently occur. By realizing this, buildings in Indonesia need to calculate earthquake loads based on SNI 03-1726-2019 to minimize victims due to building collapse when earthquakes occur.It is also necessary to evaluate the performance level of a building, in this case a 6-storey building located in the Malang area. For determining the level of performance, a method called Non-Linear Time History Analysis is used. In this calculation used San Fernando, Kobe and Landers ground motion.Based on the results from the evaluation using the Non-Linear Time History method got the maximum drift story 0.137 m that occurs in Kobe ground motion. So that the maximum total drift Dt / H is 0.137 / 21.95 = 0.0063 <0.01. Based on these results, the building performance level includes IO (Immediate Occupancy).  AbstrakIndonesia termasuk daerah ring of fire dimana suatu daerah yang sering terjadi gempa. Dengan menyadari hal tersebut, bangunan-bangunan yang ada di Indonesia perlu memperhitungkan beban gempa yang ada berdasarkan SNI 03-1726-2019 untuk meminimalisir korban akibat keruntuhan bangungan yang terjadi akibat gempa. Karena itu perlu juga untuk mengevaluasi level kinerja suatu gedung dalam hal ini gedung 6 lantai yang terletak di daerah Malang. Pada gedung ini untuk dapat diketahui level kinerjanya, maka, digunakan metode yang bernama Non-Linear Time History Analisis. Ground motion yang dipakai adalah San Fernando, Kobe dan LandersBerdasarkan hasil yang diperoleh dari evaluasi dengan metode Non-Linear Time History Analisis ini adalah maximum drift story terbesar adalah 0,137 m yang terjadi pada ground motion Kobe. Sehingga Maximum total driftnya Dt/H adalah 0,137/21,95 =0,0063<0,01. Berdasar hasil tersebut lever kinerja gedung termasuk IO (Immediate Occupancy).


Author(s):  
Fatemeh Jalayer ◽  
Hossein Ebrahimian ◽  
Andrea Miano

AbstractThe Italian code requires spectrum compatibility with mean spectrum for a suite of accelerograms selected for time-history analysis. Although these requirements define minimum acceptability criteria, it is likely that code-based non-linear dynamic analysis is going to be done based on limited number of records. Performance-based safety-checking provides formal basis for addressing the record-to-record variability and the epistemic uncertainties due to limited number of records and in the estimation of the seismic hazard curve. “Cloud Analysis” is a non-linear time-history analysis procedure that employs the structural response to un-scaled ground motion records and can be directly implemented in performance-based safety-checking. This paper interprets the code-based provisions in a performance-based key and applies further restrictions to spectrum-compatible record selection aiming to implement Cloud Analysis. It is shown that, by multiplying a closed-form coefficient, code-based safety ratio could be transformed into simplified performance-based safety ratio. It is shown that, as a proof of concept, if the partial safety factors in the code are set to unity, this coefficient is going to be on average slightly larger than unity. The paper provides the basis for propagating the epistemic uncertainties due to limited sample size and in the seismic hazard curve to the performance-based safety ratio both in a rigorous and simplified manner. If epistemic uncertainties are considered, the average code-based safety checking could end up being unconservative with respect to performance-based procedures when the number of records is small. However, it is shown that performance-based safety checking is possible with no extra structural analyses.


2010 ◽  
Vol 02 (01) ◽  
pp. 115-134
Author(s):  
YEOU-FONG LI ◽  
TSENG-HSING HSU ◽  
K. H. LEN

In this paper, the mechanical behaviors of bridges with unseating prevention devices in the superstructure were investigated. These devices can prevent bridge from unseating and divert most of the seismic forces from transferring to the bridge columns. The models of the rubber bearing, restrainer, and shear key were proposed and implemented into the SAP 2000 to obtain the seismic response of the bridge. The nonlinear time history analysis was used to determine the time history response of the superstructure of the bridge. In the meantime, the Hilbert–Huang Transform (HHT) was used to transfer the displacement–time responses of the superstructure of the bridge into the time–frequency domain, while the spectra are a function of both frequency and time. The spectra of the HHT can be used to determine the operation sequences of the unseating prevention devices.


2021 ◽  
Vol 6 (2) ◽  
pp. 98
Author(s):  
Ilham Ilham

ABSTRAKPenggunaan bresing tahan tekuk dapat menjadi solusi atas kebutuhan struktur tahan gempa di Indonesia. Disipasi energi pada elemen bresing tahan tekuk dilakukan melalui kinerja plastifikasi bagian inti bresing akibat beban tarik dan tekan. Penelitian ini berisi kajian kinerja dari bangunan rangka baja beraturan dengan bresing tahan tekuk (BRB) dengan variasi level ketinggian lantai yaitu 3 lantai, 8 lantai dan 15 lantai. Analisis struktur 3D dilakukan dengan dua prosedur analisis yaitu modal pushover dan nonlinear time history pada program ETABS. Hasil analisis menunjukkan bahwa pemilihan elemen BRB sangat mempengaruhi kinerja struktur, yang terlihat dari pola drift yang terjadi. Untuk struktur beraturan dengan berbagai ketinggian, tingkat kinerja struktur dengan BRB cukup baik, yaitu Immediate Occupancy (IO) akibat beban gempa rencana. Plastifikasi hanya terjadi pada BRB, dan kelelehan pada balok mulai terbentuk sampai mekanisme keruntuhan terjadi. Hasil modal pushover dengan nonlinear time history pada bangunan 15 lantai yang cukup mirip menunjukkan bahwa modal pushover dapat digunakan untuk memprediksi kinerja struktur BRB yang beraturan.Kata kunci: kinerja struktur, bresing tahan tekuk, immediate occupancy, modal pushover, nonlinear time history ABSTRACTBuckling restrained braces (BRB) can be an alternative solution for earthquake resistant steel structure in Indonesia. The energy dissipation for buckling restrained elements is conducted through yielding of the core due to tension or compression forces. This study presents an evaluation of the structural performance of steel structures with BRB varying in heights, 3-story, 8-story and 15-story. The 3D structural analysis was carried out with ETABS software using 2 methods, Modal Pushover and Nonlinear Time History. The results shows that the selection of BRB elements greatly affected the structural performance, showed by the drift pattern. For regular structures with variation in heights, structures with BRB behaved satisfactory under the design load with the performance level of Immediate Occupancy (IO). Yielding was limited to BRB members, and afterwards the yielding occurred on beams until collapse. The results of modal pushover and time history analysis for 15-story structure are similar, thus modal pushover can be used to predict the performance of regular structural system with BRB.Keywords: structural performance, buckling restrained brace, immediate occupancy, modal pushover analysis, nonlinear time history analysis


Sign in / Sign up

Export Citation Format

Share Document