Evaluation of Structure Performance under Seismic Load with Non-Liner Time History on High-Rise Building Affected by Kendeng Fault Earthquake Simulation

2021 ◽  
Vol 879 ◽  
pp. 232-242
Author(s):  
A.N. Refani ◽  
Yuyun Tajunnisa ◽  
K. Yudoprasetyo ◽  
F. Ghifari ◽  
D.I. Wahyudi

Indonesia is a country located in the convergence of small plates and large plates. Furthermore, this causes Indonesia to be high potentially to earthquake hazards. The newest geological research published by Geophysical Research Letter (2016) shows the existence of Fault Kendeng, a fault stretches along 300 km from South Semarang, Central Java, to East Java with a movement of 0,05 millimeter per year [1]. As a result of its research, an evaluation using a non-linear time history analysis for structural buildings is necessary. The objective of this study is to evaluate structural buildings using a non-linear time history analysis. This study applies DSHA (Deterministic Seismic Hazard Analysis) method to obtain acceleration time history on bedrocks. Since the record of ground movement in Indonesia is limited, the attenuation function equation used to scale and match other country’s time acceleration history data. SSA (Site-Specific Analysis) is used to propagate earthquake acceleration from bedrocks to the surface. The earthquake acceleration on the surface generates as the earthquake load on the buildings. The results of Kendeng fault earthquake simulation using non-linear time history analysis shows that column members capacity is more robust than beam members capacity which the beam collapse mechanism occurs initially. From the maximum total drift ratio result, when the Kendeng fault earthquake occurs, the building structure performance level is at collapse prevention level Based on ATC-40 [2]. This research result shows that 96,7% of plastic hinge has not yielded. However, some elements are already damaged. Since most damage members are column, then it may require column strengthening to enhance maximum performance level at life safety condition category.

2017 ◽  
Vol 13 ◽  
pp. 20 ◽  
Author(s):  
Petr Čada ◽  
Jiří Máca

This paper investigates effects of the seismic load to a structure. The article describes main methods of the definition and practical application of the seismic load based on the Standard Eurocode 8. There was made a comparison of all methods using the same structure. A simple two-storeyed concrete 2D-frame with fixed joints was chosen. A one another model with rigid beams for some calculations was defined. The second model can be used for hand-calculations as a cantilever with two masses. The paper describes main dynamic properties of the chosen structure. Seismic load was defined by lateral force method, modal response spectrum, non-linear time-history analysis and pushover analysis. The time-history analysis is represented by accelerograms. There were made linear and non-linear calculations.


EXTRAPOLASI ◽  
2021 ◽  
Vol 18 (1) ◽  
pp. 33-41
Author(s):  
Nurul Rochmah ◽  
Michella Beatrix ◽  
Bantot Sutriono

AbstractIndonesia is a ring of fire area where earthquakes frequently occur. By realizing this, buildings in Indonesia need to calculate earthquake loads based on SNI 03-1726-2019 to minimize victims due to building collapse when earthquakes occur.It is also necessary to evaluate the performance level of a building, in this case a 6-storey building located in the Malang area. For determining the level of performance, a method called Non-Linear Time History Analysis is used. In this calculation used San Fernando, Kobe and Landers ground motion.Based on the results from the evaluation using the Non-Linear Time History method got the maximum drift story 0.137 m that occurs in Kobe ground motion. So that the maximum total drift Dt / H is 0.137 / 21.95 = 0.0063 <0.01. Based on these results, the building performance level includes IO (Immediate Occupancy).  AbstrakIndonesia termasuk daerah ring of fire dimana suatu daerah yang sering terjadi gempa. Dengan menyadari hal tersebut, bangunan-bangunan yang ada di Indonesia perlu memperhitungkan beban gempa yang ada berdasarkan SNI 03-1726-2019 untuk meminimalisir korban akibat keruntuhan bangungan yang terjadi akibat gempa. Karena itu perlu juga untuk mengevaluasi level kinerja suatu gedung dalam hal ini gedung 6 lantai yang terletak di daerah Malang. Pada gedung ini untuk dapat diketahui level kinerjanya, maka, digunakan metode yang bernama Non-Linear Time History Analisis. Ground motion yang dipakai adalah San Fernando, Kobe dan LandersBerdasarkan hasil yang diperoleh dari evaluasi dengan metode Non-Linear Time History Analisis ini adalah maximum drift story terbesar adalah 0,137 m yang terjadi pada ground motion Kobe. Sehingga Maximum total driftnya Dt/H adalah 0,137/21,95 =0,0063<0,01. Berdasar hasil tersebut lever kinerja gedung termasuk IO (Immediate Occupancy).


Author(s):  
Fatemeh Jalayer ◽  
Hossein Ebrahimian ◽  
Andrea Miano

AbstractThe Italian code requires spectrum compatibility with mean spectrum for a suite of accelerograms selected for time-history analysis. Although these requirements define minimum acceptability criteria, it is likely that code-based non-linear dynamic analysis is going to be done based on limited number of records. Performance-based safety-checking provides formal basis for addressing the record-to-record variability and the epistemic uncertainties due to limited number of records and in the estimation of the seismic hazard curve. “Cloud Analysis” is a non-linear time-history analysis procedure that employs the structural response to un-scaled ground motion records and can be directly implemented in performance-based safety-checking. This paper interprets the code-based provisions in a performance-based key and applies further restrictions to spectrum-compatible record selection aiming to implement Cloud Analysis. It is shown that, by multiplying a closed-form coefficient, code-based safety ratio could be transformed into simplified performance-based safety ratio. It is shown that, as a proof of concept, if the partial safety factors in the code are set to unity, this coefficient is going to be on average slightly larger than unity. The paper provides the basis for propagating the epistemic uncertainties due to limited sample size and in the seismic hazard curve to the performance-based safety ratio both in a rigorous and simplified manner. If epistemic uncertainties are considered, the average code-based safety checking could end up being unconservative with respect to performance-based procedures when the number of records is small. However, it is shown that performance-based safety checking is possible with no extra structural analyses.


Author(s):  
Iswandi Imran ◽  
Marie Hamidah ◽  
Tri Suryadi ◽  
Hasan Al-Harris ◽  
Syamsul Hidayat

<p>In order to overcome stringent seismic requirement in the new Greater Jakarta Light Rail Transit Project, a breakthrough seismic system shall be chosen to obtain expected structural performance. This seismic system shall be designed to provide operational performance level after strong earthquake events. To achieve the criteria, seismic isolation system using Lead Rubber Bearings is chosen. With this isolation system, Greater Jakarta LRT has become the first seismically isolated infrastructure and apparently an infrastructure with the largest numbers of LRBs in one single project in Indonesia. More than 10.400 Pcs LRBs are used for the first phase of the construction and the numbers will be certainly increased in the next phase of the construction. To evaluate the structural performance, non-linear time history analysis is used. A total of 3 pair matched ground motions will be used as the input for the response history analysis. The ability of the lead rubber bearing to isolate and dissipate earthquake actions will determine its structural performance level. This will be represented by the nonlinear hysteretic curves obtained throughout the earthquake actions.</p>


2019 ◽  
Vol 10 (2) ◽  
pp. 166-184
Author(s):  
Johnny Setiawan ◽  
Iswandi Imran

Terdapat cukup banyak perubahan pada SNI 1726-2012, salah satunya adalah adanya persyaratanbatas geser dasar minimum (minimum base shear) yang tidak ada pada peraturan sebelumnya.Metode yang akan dilakukan adalah bangunan gedung dengan klasifikasi ketinggian rendah,sedang dan tinggi akan dianalisis dengan menerapkan geser dasar minimum dan tanpa geser dasarminimum. Analisis yang akan digunakan adalah analisis ragam spektrum respons (ResponsSpectrum Analysis, RSA), analisis respons riwayat waktu (Time History Analysis, THA) dananalisis respons riwayat waktu non linier (Non Linear Time History Analysis, NLTHA). Hasilanalisis menunjukkan bahwa pada peraturan SNI 1726-2012 dengan adanya persyaratan batasangeser dasar minimum dapat menjamin kinerja struktur sesuai dengan yang diharapkan.Kekhawatiran adanya batasan geser dasar minimum pada SNI 1726-2012 akan membuat desainmenjadi tidak ekonomis, ternyata tidak terbukti karena tidak memberikan pengaruh signifikanpada hasil desain, khususnya untuk bangunan dengan kategori ketinggian rendah dan sedang.Untuk bangunan dengan klasifikasi bangunan tinggi, analisis dan desain dengan memperhitungansyarat batasan geser dasar minimum dan tanpa memperhitungkan geser dasar minimum dapatmemberikan hasil desain yang baik, tetapi pengecekan pada Level Kinerja (Performance Level)sesuai dengan story drift menunjukkan bahwa analisis dengan memperhitungkan syarat geser dasarminimum memberikan hasil dengan level kinerja yang cukup baik yaitu Immediate Occupancy(IO) hingga Damage Control (DO), sedangkan tanpa memperhitungkan geser dasar minimummemberikan hasil dengan level kinerja yang kurang baik yaitu Life Safety (LS) hingga StructuralStability (SS). Sedangkan pada level kinerja elemen struktur, analisis tanpa memperhitungkangeser dasar minimum menyebabkan banyak elemen struktur yang berada pada level kinerjaCollapse Prevention (CP).


Sign in / Sign up

Export Citation Format

Share Document