scholarly journals Vision Sensor Calibration Method based on Flexible 3d Target and Invariance of Cross Ratio

Author(s):  
Jingli Wei ◽  
Zhiwei Liu ◽  
Fangling Cheng
2011 ◽  
Vol 317-319 ◽  
pp. 397-400
Author(s):  
Gang Chen ◽  
Hua Chen ◽  
Yu Bo Guo ◽  
Dong Ye

This paper presents and comparison two stereo vision sensor calibration methods: Volume template based calibration method and the calibration based on virtual stereo pattern. First method use a premade volume template. Second method use a group of random spatial points that are formed by an infrared LED moved with the probe of CMM. Two methods adopt an ideal pin-hole model that ignores the nonlinear distortion of the cameras. Through compare two calibratioin methods, we can draw conclusion that the first method can be applide to stereo sensor calibration in measurement field and the second method could gain higher calibrating precision.


IEEE Access ◽  
2021 ◽  
Vol 9 ◽  
pp. 44354-44362
Author(s):  
Mingwei Shao ◽  
Pan Wang ◽  
Yanjun Wang

2009 ◽  
Vol 29 (11) ◽  
pp. 3124-3128 ◽  
Author(s):  
刘震 Liu Zhen ◽  
张广军 Zhang Guangjun ◽  
魏振忠 Wei Zhenzhong ◽  
江洁 Jiang Jie

2013 ◽  
Vol 33 (3) ◽  
pp. 0315001
Author(s):  
刘震 Liu Zhen ◽  
尚砚娜 Shang Yanna

Sensors ◽  
2018 ◽  
Vol 18 (10) ◽  
pp. 3485 ◽  
Author(s):  
Dongdong Chen ◽  
Peijiang Yuan ◽  
Tianmiao Wang ◽  
Ying Cai ◽  
Haiyang Tang

To enhance the perpendicularity accuracy in the robotic drilling system, a normal sensor calibration method is proposed to identify the errors of the zero point and laser beam direction of laser displacement sensors simultaneously. The procedure of normal adjustment of the robotic drilling system is introduced firstly. Next the measurement model of the zero point and laser beam direction on a datum plane is constructed based on the principle of the distance measurement for laser displacement sensors. An extended Kalman filter algorithm is used to identify the sensor errors. Then the surface normal measurement and attitude adjustments are presented to ensure that the axis of the drill bit coincides with the normal at drilling point. Finally, simulations are conducted to study the performance of the proposed calibration method and experiments are carried out on a robotic drilling system. The simulation and experimental results show that the perpendicularity of the hole is within 0.2°. They also demonstrate that the proposed calibration method has high accuracy of parameter identification and lays a basis for high-precision perpendicularity accuracy of drilling in the robotic drilling system.


Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1923
Author(s):  
Shuang Zhao ◽  
Jun Liu ◽  
Yansong Li

At present, most sensor calibration methods are off-line calibration, which not only makes them time-consuming and laborious, but also causes considerable economic losses. Therefore, in this study, an online calibration method of current sensors is proposed to address the abovementioned issues. The principle and framework of online calibration are introduced. One of the calibration indexes is angular difference. In order to accurately verify it, data acquisition must be precisely synchronized. Therefore, a precise synchronous acquisition system based on GPS timing is proposed. The influence of ionosphere on the accuracy of GPS signal is analyzed and a new method for measuring the inherent delay of GPS receiver is proposed. The synchronous acquisition performance of the system is verified by inter-channel synchronization experiment, and the results show that the synchronization of the system is accurate. Lastly, we apply our online calibration method to the current sensor; the experimental results show that the angular difference and ratio difference meet the requirements of the national standard and the accuracy of the online calibration system can be achieved to 0.2 class, demonstrating the effectiveness of the proposed online calibration method.


2014 ◽  
Vol 709 ◽  
pp. 496-499
Author(s):  
Yu Qin Li ◽  
Ying Jun Li ◽  
Huan Yong Cui ◽  
Gui Cong Wang ◽  
Xi Jie Tian

As a mechanical component, sensor can detect spatial information. Sensor technology has been widely used in national defense, aerospace, industrial inspection and automated production areas and so on. However, the sensor calibration device cannot meet the demand of the development of the sensor. In this paper, a multi-functional force loading device, which is of good technical performance, reliable operation, wide measurement range and simple measurement method, and a six-dimensional force sensor calibration method are described.


Sign in / Sign up

Export Citation Format

Share Document