simple measurement
Recently Published Documents


TOTAL DOCUMENTS

380
(FIVE YEARS 65)

H-INDEX

28
(FIVE YEARS 3)

Chemosensors ◽  
2022 ◽  
Vol 10 (1) ◽  
pp. 35
Author(s):  
Marina Nadporozhskaya ◽  
Ninel Kovsh ◽  
Roberto Paolesse ◽  
Larisa Lvova

The continuously rising interest in chemical sensors’ applications in environmental monitoring, for soil analysis in particular, is owed to the sufficient sensitivity and selectivity of these analytical devices, their low costs, their simple measurement setups, and the possibility to perform online and in-field analyses with them. In this review the recent advances in chemical sensors for soil analysis are summarized. The working principles of chemical sensors involved in soil analysis; their benefits and drawbacks; and select applications of both the single selective sensors and multisensor systems for assessments of main plant nutrition components, pollutants, and other important soil parameters (pH, moisture content, salinity, exhaled gases, etc.) of the past two decades with a focus on the last 5 years (from 2017 to 2021) are overviewed.


Sensors ◽  
2022 ◽  
Vol 22 (2) ◽  
pp. 516
Author(s):  
Alessandro Rizzo ◽  
Francesco Cardellini ◽  
Claudio Poggi ◽  
Enrico Borra ◽  
Luca Ciciani ◽  
...  

Nowadays, radon gas exposure is considered one of the main health concerns for the population because, by carrying about half the total dose due to environmental radioactivity, it is the second cause of lung cancer after smoking. Due to a relatively long half-life of 3.82 days, the chemical inertia and since its parent Ra-226 is largely diffuse on the earthrgb]0,0,1’s crust and especially in the building materials, radon can diffuse and potentially saturate human habitats, with a concentration that can suddenly change during the 24 h day depending on temperature, pressure, and relative humidity. For such reasons, `real-time’ measurements performed by an active detector, possibly of small dimensions and a handy configuration, can play an important role in evaluating the risk and taking the appropriate countermeasures to mitigate it. In this work, a novel algorithm for pattern recognition was developed to exploit the potentialities of silicon active detectors with a pixel matrix structure to measure radon through the α emission, in a simple measurement configuration, where the device is placed directly in air with no holder, no collection filter or electrostatic field to drift the radon progenies towards the detector active area. This particular measurement configuration (dubbed as bare) requires an α/β-discrimination method that is not based on spectroscopic analysis: as the gas surrounds the detector the α particles are emitted at different distances from it, so they lose variable energy amount in air depending on the traveled path-length which implies a variable deposited energy in the active area. The pixels matrix structure allows overcoming this issue because the interaction of α, β and γ particles generate in the active area of the detector clusters (group of pixels where a signal is read) of different shape and energy dispersion. The novel algorithm that exploits such a phenomenon was developed using a pixelated silicon detector of the TimePix family with a compact design. An α(Am-241) and a β(Sr-90) source were used to calibrate the algorithm and to evaluate its performances in terms of β rejection capability and α recognition efficiency. Successively, the detector was exposed to different radon concentrations at the ENEA-INMRI radon facility in `bare’ configuration, in order to check the linearity of the device response over a radon concentration range. The results for this technique are presented and discussed, highlighting the potential applications especially the possibility to exploit small and handy detectors to perform radon active measurements in the simplest configuration.


2021 ◽  
Vol 7 (2) ◽  
pp. 167-186
Author(s):  
Mayowa Akinlotan

The choice between since and because allows language users to provide rationality which is part of the cognitive functions of language. Different conditions have been shown to explicate this alternation, with little attention paid to the clausal weight. The present paper shows how expression of rationality is alternated between choosing a since or because, since both have the semantic capacity to do so, in certain contexts. The study uses a simple measurement method to show the extent to which clausal weight relates to this alternation. Relying on corpus data from a well-known variety representing Nigerian English, the present study shows that the choice between since and because is related to a number of factors such as the type of text producing the usages. With 1074 usages showing such interchangeable usages extracted from academic and media text types in written Nigerian English, it is shown that, at least in the variety under examination, the choice of since over because as a rationality expresser is scarce, and that overall pattern can be predicted on the basis of certain contexts including clausal weight and ordering pattern. The scarcity of since as a rationality expresser is perhaps a reflection of interference from the local languages, which do not have semantic equivalents.


Crystals ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 1553
Author(s):  
Jui-Fen Chang ◽  
Shun-Yu Hong ◽  
Yi Chen ◽  
Yan-Rong Huang ◽  
Chung-Ken Lin ◽  
...  

The multifunctional snapshot angle-resolved spectroscopy (ARS) system capable of electroluminescence, photoluminescence, and reflectance measurements for thin film devices is developed based on the k-space imaging technique. Compared with the conventional goniometric ARS system, this snapshot spectroscopy system offers great advantages of rapid and simple measurement, suitable for characterizing thin film devices that are unstable or degraded under long-time or high-power driving conditions, such as OLEDs. We perform a detailed calibration of the snapshot system and show that the measured results closely match with those obtained using a goniometric system. Furthermore, we show the capabilities of the system with application in studying polariton OLEDs. The result provides comprehensive information on the polariton mode dispersion and emission distribution, and shows an effective radiative pumping of the lower polariton branch for high emission efficiency.


PLoS ONE ◽  
2021 ◽  
Vol 16 (11) ◽  
pp. e0259760
Author(s):  
Noah James Langenfeld ◽  
Lauren Elizabeth Payne ◽  
Bruce Bugbee

Urea is a byproduct of the urea cycle in metabolism and is excreted through urine and sweat. Ammonia, which is toxic at low levels, is converted to the safe storage form of urea, which represents the largest efflux of nitrogen from many organisms. Urea is an important nitrogen source in agriculture, is added to many industrial products, and is a large component in wastewater. The enzyme urease hydrolyzes urea to ammonia and bicarbonate. This reaction is microbially mediated in soils, hydroponic solutions, and wastewater recycling and is catalyzed in vivo in plants using native urease, making measurement of urea environmentally important. Both direct and indirect methods to measure urea exist. This protocol uses diacetyl monoxime to directly determine the concentration of urea in solution. The protocol provides repeatable results and stable reagents with good color stability and simple measurement techniques for use in any lab with a spectrophotometer. The reaction between diacetyl monoxime and urea in the presence of sulfuric acid, phosphoric acid, thiosemicarbazide, and ferric chloride produces a chromophore with a peak absorbance at 520 nm and a linear relationship between concentration and absorbance from 0.4 to 5.0 mM urea in this protocol. The lack of detectable interferences makes this protocol suitable for the determination of millimolar levels of urea in wastewater streams and hydroponic solutions.


2021 ◽  
Author(s):  
Jiarui Wu ◽  
Xu Yang ◽  
Kangping Wang ◽  
Jiwen Wei ◽  
Zhiyuan Qi ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (19) ◽  
pp. 6675
Author(s):  
Viktor Fairuschin ◽  
Felix Brand ◽  
Alexander Backer ◽  
Klaus Stefan Drese

Nondestructive evaluation of elastic properties plays a critical role in condition monitoring of thin structures such as sheets, plates or tubes. Recent research has shown that elastic properties of such structures can be determined with remarkable accuracy by utilizing the dispersive nature of guided acoustic waves propagating in them. However, existing techniques largely require complicated and expensive equipment or involve accurate measurement of an additional quantity, rendering them impractical for industrial use. In this work, we present a new approach that requires only a pair of piezoelectric transducers used to measure the group velocities ratio of fundamental guided wave modes. A numerical model based on the spectral collocation method is used to fit the measured data by solving a bound-constrained nonlinear least squares optimization problem. We verify our approach on both simulated and experimental data and achieve accuracies similar to those reported by other authors. The high accuracy and simple measurement setup of our approach makes it eminently suitable for use in industrial environments.


2021 ◽  
Vol 4 (s1) ◽  
Author(s):  
Francesco Bacchi ◽  
Azzurra Sargenti ◽  
Francesco Musmeci ◽  
Simone Pasqua ◽  
Simone Bonetti ◽  
...  

The simple measurement of mass density, size and weight of sphere-like 3D cell models has been recently enabled by a specifically conceived flow-based method. Here we demonstrate that such technique also allows the post-analysis collection of live 3D tumor spheroids, without compromising their viability.


2021 ◽  
Vol 11 (8) ◽  
pp. 799
Author(s):  
Shi-Chue Hsing ◽  
Chin Lin ◽  
Jiann-Torng Chen ◽  
Yi-Hao Chen ◽  
Wen-Hui Fang

(1) Background: Recent studies have reported that the glucose variability (GV), irrespective of glycosylated hemoglobin (HbA1c), could be an additional risk factor for the development of diabetic retinopathy (DR). However, measurements for GV, such as continuous glucose monitoring (CGM) and fasting plasma glucose (FPG) variability, are expensive and time consuming. (2) Methods: This present study aims to explore the correlation between the glycemic gap as a measurement of GV, and DR. In total, 2565 patients were included in this study. We evaluated the effect of the different types of glycemic gaps on DR progression. (3) Results: We found that the area under the curve (AUC) values of both the glycemic gap and negative glycemic gap showed an association with DR progression. (4) Conclusions: On eliminating the possible influences of chronic blood glucose controls, the results show that GV has deleterious effects that are associated with the progression of DR. The glycemic gap is a simple measurement of GV, and the predictive value of the negative glycemic gap in DR progression shows that GV and treatment-related hypoglycemia may cause the development of DR. Individual treatment goals with a reasonable HbA1c and minimal glucose fluctuations may help in preventing DR.


Sign in / Sign up

Export Citation Format

Share Document