scholarly journals Spatial dependency of groundwater quality in Benin City, Edo State, Nigeria using semi-variogram models

Author(s):  
Maryann Ogoamaka Ezugwu ◽  
Eguakhide Atikpo

Water quality is a worldwide concern especially water for human consumption. Regular monitoring and tools should be developed, to ensure continuous assessment of the level of concentration of chemical constituents prevalent in water. This will guide against health dangers and risks associated with water of low quality. The research focus on using semi-variogram models to measure the degree of spatial dependency of sampled boreholes for prediction of the concentration of water quality parameters at un-sampled locations because of the cumbersome nature of assessing the whole boreholes in Benin City. One hundred and ten (110) different domestic boreholes were systematically sampled and analyzed in laboratory for determination of the concentration of some chemical water quality parameters which include Electrical Conductivity (EC), Total Dissolve Solids (TDS), Bicarbonate (HCO3), Sodium (Na), Potassium (K), Calcium (Ca), Magnesium (Mg), etc. Laboratory examination of boreholes water quality parameters were carried out in wet and dry seasons. Geographical locations of sampled boreholes were also determined. The obtained experimental results were utilized in investigating the spatial structure of the boreholes using semi-variogram models which include spherical, exponential, Gaussian etc. Exponential model was the most fitted model. The borehole water quality parameters exhibited high degree of spatial dependency in EC, TDS, HCO3, Na, K, Ca. Mg, Cl, P, and NO3 in both seasons with ratio < 25% therefore, interpolation technique can be employed to produce spatial variation quality map of boreholes in Benin City as a monitoring technique to detect contamination or changes in water quality.

The present paper describes the application of GIS to study the spatial and temporal variations of some important water quality parameters in the Veeranam tank drainage basin of cuddalore district, Tamil Nadu, South India. The water quality parameters were depicted by various colour combinations for different ranges of concentrations. Twenty four (24) groundwater samples were collected from bore wells for two different seasons, pre monsoon in July 2015 and postmonsoon in January 2016. The collected water samples were analyzed for chemical constituents, such as chloride, sulphate, bicarbonate, carbonate, nitrate, sodium, potassium, calcium and magnesium in the laboratory, by following the standard procedures described by the American Public Health Association (APHA 1998). Spatial distribution map for Electrical conductivity, Hardness, Calcium, Magnesium, Sulphate and Chloride in pre-monsoon and post monsoon samples was generated by ArcGIS 9.3 software. The study implies that the quality of groundwater is generally good and potable in the nearby Veeranam lake and the quality becomes moderate as it passes away from Veeranam tank of the study area.


2009 ◽  
Vol 1 (2) ◽  
pp. 159-165
Author(s):  
D. Slathia ◽  
S. P. S. Dutta

Water quality parameters viz. air temperature (15.21 0 C -36 0 C/16.71 0 C - 39.42 0 C), water temperature (13 0 C-32.42 0 C/15 0 C-32.8 0 C), depth (42cm-69.08cm/ 25cm-121.92cm), turbidity (3.88-46.27NTU/3.67-69.39 NTU), salinity (0.10-0.31ppt/ 0.10-0.37ppt), electrical conductivity (0.101-0.172mS/cm/0.114-0.279mS/cm), TDS (49.63-111.78 mg/l/57.64-177.01mg/l), pH (7.92-9.82/7.80-9.09), free CO2 (0-19.22mg/l/0-15.32mg/l), DO (6.82-9.90mg/l/4.65-9.40mg/l), carbonate (0-18.38mg/l/0-20.63mg/l), bicarbonate (60.99-170.70mg/l/77.62-168.70mg/l, chloride (7.41-12.35mg/l/9.59-19.60mg/l), calcium (6.85-38.50mg/l/11.81-140.49mg/l), magnesium (4.62-7.22mg/l/3.86-39.05mg/l), total hardness (40.29-125.50 mg/l/56.61-511.05mg/l), BOD (3.12-5.79mg/l/1.31-16.21 mg/l), COD (17.74-75.42 mg/l/ 26.57-73.03mg/l), sodium (14.2-22.5mg/l/12.2-30.9mg/l), potassium (1.83-4.17mg/l/2.25-6.21mg/l), phosphate (0.048-0.233mg/l/0.008-0.603mg/l), nitrate (0.13-1.3mg/l/0.11-4.08mg/l), sulphate (1.60-19.19mg/l/1.36-15.70mg/l), silicate (0.14-4.23mg/l/0.27-7.05mg/l), iron (0-0.65/0-0.40mg/l), copper (below detectable limit) and zinc (below detectable limit), of lake Surinsar-the only source of drinking water to the inhabitants of the Surinsar village, have been reported monthly, during the year 2002-03/2003-04. WQI range falls from poor (70.45, December; 73.55, October; 74.4, November and 74.56, September/ 74.52, January and 75.36, September), very poor(82.54, February; 89.25, May; 80.76, August and 78.86, January/ 80.89, February; 98.25, April; 80.03, June; 82.26, July; 86.55, October and 83.03, November) to unfit (100.44, June; 101.9, July; 103.86, April and 119.5, March/ 103.73, May; 108.28, March; 122.56, August and 103.72, December). Comparison of range of various water quality parameters of Surinsar lake water, with national and international standards has also revealed that most of these parameters are beyond permissible limits. This clearly indicates the unsuitability of raw water, generally consumed by local inhabitants, for human consumption.


2015 ◽  
Vol 7 (1) ◽  
pp. 257-263 ◽  
Author(s):  
A Munnaf ◽  
MS Islam ◽  
TR Tusher ◽  
MH Kabir ◽  
MAH Molla

Rapid development of textile industry and direct deposition of the effluents into sewage networks produced disturbances in treatment processes and exert pollution loads on water bodies. The study was conducted to investigate the water quality parameters discharged from seven textile dyeing industries at Konabari in Gazipur region of Bangladesh during March to December, 2011, and also to evaluate the harmful effects of effluents on the surrounding environment. Emphasis was given on the investigation of important water quality parameters, which include temperature, pH, total suspended solids (TSS), total dissolved solids (TDS), dissolved oxygen (DO), biochemical oxygen demand (BOD) and chemical oxygen demand (COD), along with the management techniques of effluents discharged from textile dyeing industries. The study depicted that the DO values were nil or below the standard values in all industries which was very alarming for environment. The concentrations of BOD, COD, TDS and TSS were very high which indicate the presence of water pollutants. The study was focused on the pollution implications of effluents from textile industries around the study area, because of the risk of human exposure and environmental degradation by these massive discharged effluents. The water quality deteriorated in dry season than the wet season and the surface water around the studied area was highly polluted due to the industrial activities and should totally avoid for human consumption without proper treatment. It is therefore recommended that the careless discharge of the effluents should be discouraged and appropriate management system should be taken immediately to reduce the water pollution for saving the environment.DOI: http://dx.doi.org/10.3329/jesnr.v7i1.22180 J. Environ. Sci. & Natural Resources, 7(1): 257-263 2014


2019 ◽  
Vol 17 (3) ◽  
pp. 1387-1396 ◽  
Author(s):  
C. M. E. Pompei ◽  
E. D. L. Alves ◽  
E. M. Vieira ◽  
L. C. Campos

Abstract Recently, special attention has been given to low-cost technologies for water treatment, with the aim of serving remote communities and thus enabling everyone to have access to drinking water and basic sanitation. In that context, the ecological filter is an alternative for treating water for human consumption. Some studies show that climate change and meteorological parameters can influence the water quality of water bodies and the water supply system. However, most of the papers deal with model projections and therefore do not show real situations. The aim of this study was to determine the impact of meteorological variables (e.g. atmospheric pressure, evaporation, wind speed, radiation, precipitation) on the physico-chemical and biological parameters (e.g. turbidity, apparent colour, pH, total coliforms, Escherichia coli) of Lobo reservoir water treated by 22 ecological filters during a period of 4 months. Statistically significant correlations were found between the water from the Lobo reservoir and the weather variables, and between the water quality parameters of the 22 ecological filters and the average weather variables. The results from the statistical analysis indicate that climatic variations may influence treatment performance.


2015 ◽  
Vol 8 (1) ◽  
pp. 85-89
Author(s):  
F Zannat ◽  
MA Ali ◽  
MA Sattar

A study was conducted to evaluate the water quality parameters of pond water at Mymensingh Urban region. The water samples were collected from 30 ponds located at Mymensingh Urban Region during August to October 2010. The chemical analyses of water samples included pH, EC, Na, K, Ca, S, Mn and As were done by standard methods. The chemical properties in pond water were found pH 6.68 to 7.14, EC 227 to 700 ?Scm-1, Na 15.57 to 36.00 ppm, K 3.83 to 16.16 ppm, Ca 2.01 to 7.29 ppm, S 1.61 to 4.67 ppm, Mn 0.33 to 0.684 ppm and As 0.0011 to 0.0059 ppm. The pH values of water samples revealed that water samples were acidic to slightly alkaline in nature. The EC value revealed that water samples were medium salinity except one sample and also good for irrigation. According to drinking water standard Mn toxicity was detected in pond water. Considering Na, Ca and S ions pond water was safe for irrigation and aquaculture. In case of K ion, all the samples were suitable for irrigation but unsuitable for aquaculture.J. Environ. Sci. & Natural Resources, 8(1): 85-89 2015


2018 ◽  
Vol 69 (8) ◽  
pp. 2045-2049
Author(s):  
Catalina Gabriela Gheorghe ◽  
Andreea Bondarev ◽  
Ion Onutu

Monitoring of environmental factors allows the achievement of some important objectives regarding water quality, forecasting, warning and intervention. The aim of this paper is to investigate water quality parameters in some potential pollutant sources from northern, southern and east-southern areas of Romania. Surface water quality data for some selected chemical parameters were collected and analyzed at different points from March to May 2017.


1982 ◽  
Vol 14 (4-5) ◽  
pp. 43-58 ◽  
Author(s):  
M Rizet ◽  
J Mouchet

This study was conducted in order to understand the taste and odour problems that occurred in the Seine and the Marne rivers during the severe drought of 1976. Samples were taken every 15 days from several locations in the rivers themselves and from storage reservoirs upstream from Paris. Algae and actinomycetes were identified and counted. Metabolite concentrations were measured. These data were correlated with threshold odor numbers and bacteriological water quality parameters.


Water ◽  
2016 ◽  
Vol 8 (11) ◽  
pp. 507 ◽  
Author(s):  
Iván Vizcaíno ◽  
Enrique Carrera ◽  
Margarita Sanromán-Junquera ◽  
Sergio Muñoz-Romero ◽  
José Luis Rojo-Álvarez ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document