scholarly journals Pharmaceutical procurement practice aspects

2020 ◽  
Vol 8 (3) ◽  
pp. 337-349
Author(s):  
Abdrhman Mahmoud Gamil

Procurement is the most important part of the pharmaceutical logistic cycle. It is the process of acquiring supplies after a properly selected list of products. The procurement system or model depends on the type of organization weather it is governmental or private, centralized or decentralized, autonomous or semiautonomous. The objectives of procurement system is to make available the right drug in an appropriate quantities of adequate quality from a reliable supplier at the right time with the lowest possible prices through an ethical and legal procedures. Prequalification of suppliers is the successful quality assurance activity. Needs and funds can be reconciled and a rational cut can be done by using ABC- VAN matrix technique. Purchasing should be by transparent competition through open tender, restrictive tender, restricted competition or in certain cases by direct negotiation by transparent committee leading to transparent contract. One of the most important procurement practice for the system to succeed is the reliable payment and efficient financial management and monitoring the supplier performance. The system should have an efficient quality assurance program with annual auditing and regular reports.

2020 ◽  
Vol 3 (2) ◽  
pp. 117-132
Author(s):  
Betha Rahmasari

This article aims to find out the developmentidea or paradigm through village financial management based on Law Number 6 of 2014 concerning Villages. In this study, the researcher used a normative research methodby examining the village regulations in depth. Primary legal materials are authoritatuve legal materials in the form of laws and regulations. Village dependence is the most obvious violence against village income or financial sources. Various financial assistance from the government has made the village dependent on financial sources from the government. The use of regional development funds is intended to support activities in the management of Regional Development organizations. Therefore, development funds should be managed properly and smoothly, as well as can be used effectively to increase the people economy in the regions. This research shows that the law was made to regulate and support the development of local economic potential as well as the sustainable use of natural resources and the environment, and that the village community has the right to obtain information and monitor the planning and implementation of village development.


2004 ◽  
Vol 101 (Supplement3) ◽  
pp. 351-355 ◽  
Author(s):  
Javad Rahimian ◽  
Joseph C. Chen ◽  
Ajay A. Rao ◽  
Michael R. Girvigian ◽  
Michael J. Miller ◽  
...  

Object. Stringent geometrical accuracy and precision are required in the stereotactic radiosurgical treatment of patients. Accurate targeting is especially important when treating a patient in a single fraction of a very high radiation dose (90 Gy) to a small target such as that used in the treatment of trigeminal neuralgia (3 to 4—mm diameter). The purpose of this study was to determine the inaccuracies in each step of the procedure including imaging, fusion, treatment planning, and finally the treatment. The authors implemented a detailed quality-assurance program. Methods. Overall geometrical accuracy of the Novalis stereotactic system was evaluated using a Radionics Geometric Phantom Chamber. The phantom has several magnetic resonance (MR) and computerized tomography (CT) imaging—friendly objects of various shapes and sizes. Axial 1-mm-thick MR and CT images of the phantom were acquired using a T1-weighted three-dimensional spoiled gradient recalled pulse sequence and the CT scanning protocols used clinically in patients. The absolute errors due to MR image distortion, CT scan resolution, and the image fusion inaccuracies were measured knowing the exact physical dimensions of the objects in the phantom. The isocentric accuracy of the Novalis gantry and the patient support system was measured using the Winston—Lutz test. Because inaccuracies are cumulative, to calculate the system's overall spatial accuracy, the root mean square (RMS) of all the errors was calculated. To validate the accuracy of the technique, a 1.5-mm-diameter spherical marker taped on top of a radiochromic film was fixed parallel to the x–z plane of the stereotactic coordinate system inside the phantom. The marker was defined as a target on the CT images, and seven noncoplanar circular arcs were used to treat the target on the film. The calculated system RMS value was then correlated with the position of the target and the highest density on the radiochromic film. The mean spatial errors due to image fusion and MR imaging were 0.41 ± 0.3 and 0.22 ± 0.1 mm, respectively. Gantry and couch isocentricities were 0.3 ± 0.1 and 0.6 ± 0.15 mm, respectively. The system overall RMS values were 0.9 and 0.6 mm with and without the couch errors included, respectively (isocenter variations due to couch rotation are microadjusted between couch positions). The positional verification of the marker was within 0.7 ± 0.1 mm of the highest optical density on the radiochromic film, correlating well with the system's overall RMS value. The overall mean system deviation was 0.32 ± 0.42 mm. Conclusions. The highest spatial errors were caused by image fusion and gantry rotation. A comprehensive quality-assurance program was developed for the authors' stereotactic radiosurgery program that includes medical imaging, linear accelerator mechanical isocentricity, and treatment delivery. For a successful treatment of trigeminal neuralgia with a 4-mm cone, the overall RMS value of equal to or less than 1 mm must be guaranteed.


2020 ◽  
Vol 9 (6) ◽  
pp. S63-S64
Author(s):  
Jonathan Marotti ◽  
Diane M. Green ◽  
Rebecca Proskovec ◽  
Linda Yaman ◽  
Danielle Dunn ◽  
...  

Author(s):  
Min Wang ◽  
Xinjian Duan ◽  
Michael J. Kozluk

A probabilistic fracture mechanics code, PRAISE-CANDU 1.0, has been developed under a software quality assurance program in full compliance with CSA N286.7-99, and was initially released in 2012 June. Extensive verification and validation has been performed on PRAISE-CANDU 1.0 for the purpose of software quality assurance. This paper presents the benchmarking performed between PRAISE-CANDU 1.0 and xLPR (eXtremely Low Probability of Rupture) version 1.0 using the cases from the xLPR pilot study. The xLPR code was developed in a configuration management and quality assured manner. Both codes adopted a state-of-art code architecture for the treatment of the uncertainties. Inputs to the PRAISE-CANDU were established as close as possible to those used in corresponding xLPR cases. Excellent agreement has been observed among the results obtained from the two PFM codes in spite of some differences between the codes. This benchmarking is considered to be an important element of the validation of PRAISE-CANDU.


1994 ◽  
Vol 81 (SUPPLEMENT) ◽  
pp. A1227 ◽  
Author(s):  
S. Small ◽  
D. J. Cullen ◽  
D. Bates ◽  
J. B. Cooper ◽  
L. Leape

Sign in / Sign up

Export Citation Format

Share Document