scholarly journals Validated method for estimation of irbesartan in bulk and dosage form by high performance liquid chromatography technique

2015 ◽  
Vol 3 (03) ◽  
pp. 44-49
Author(s):  
N. S. Kulkarni ◽  
D. S. Rathor ◽  
N. S. Ranpise ◽  
S. N. Dhole

A simple, specific, accurate and precise new high performance liquid chromatographic method was developed for the estimation of irbesartan in bulk and its developed dosage form. The mobile phase containing acetonitrile: Phosphate buffer pH 3.5 in proportion of 50:50 v/v was employed with flow rate of1.0 ml/min and eluting medium was monitored at 240 nm. The method was validated for linearity, accuracy, precision, limit of detection, limit of quantification and robustness for irbesartan. A linear response was observed in the range of 5- 40μg/ml. Linear regression of absorbance on concentration gave equation y = 101.9x + 195.3 with a regression co-efficient r2 =0.993. The method was validated for different parameters as per the ICH guidelines. The degradation studies were carried out by using the developed method. Thus the method was found to be useful for the determination of irbesartan in bulk as well as for dosage forms.

2013 ◽  
Vol 10 (3) ◽  
pp. 1014-1022
Author(s):  
Baghdad Science Journal

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml respectively. The method was validated for its linearity, precision and accuracy .The proposed method was successfully applied for the determination of guaifenesin in syrups and industrial effluent samples.


2020 ◽  
Vol 11 (4) ◽  
pp. 7878-7884
Author(s):  
Gunturu Raviteja ◽  
Kantipudi Rambabu

With the quantitative analysis of Cidofovir and Famciclovir using a Symmetry C-18 150x4.6mm, 3.5 column with a flow rate of 1ml/min, a novel, quick, and accurate high performance liquid chromatographic method have been developed. The buffer is made up of 1 mL formic acid dissolved in 1 litre HPLC water, and the mobile step is made up of a 60:40 mixture of two components: Buffer and Acetonitrile. The detection was done at a wavelength of 250nm. With 8 minutes of run time, the Cidofovir and Famciclovir peaks were split, with the Cidofovir peak eluted at 2.8 minutes and the Famciclovir peak eluted at 6.4 minutes, respectively. In the concentration ranges of 7.5 g/ml to 112.5 g/ml for Cidofovir and 25 g/ml to 375 g/ml for Famciclovir, the proposed method shows strong linearity. The results of the precision and recovery studies range from 98 to 102 percent. The percent RSD in all robustness conditions is less than 2.0 percent. In stressful conditions, deterioration has a limited impact, and solutions remain stable for 24 hours. The parameters of precision, accuracy, specificity, stability, robustness, linearity, limit of detection, and limit of quantification were evaluated and found to be within the appropriate range when the method was developed and validated according to ICH guidelines.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (07) ◽  
pp. 32-37
Author(s):  
Vijaya Lakshmi Marella ◽  
Chaitanya S. N ◽  

A selective and sensitive reverse phase High Performance Liquid Chromatographic method has been developed and validated for the estimation of lornoxicam in bulk, pharmaceutical dosage forms and in dissolution samples. The analysis was performed isocratically on an Inertsil column (250* 4.6 mm, 5 µm) using a mass spectrometric compatible mobile phase of 10 mM ammonium acetate: acetonitrile (50:50 V/V) at a flow rate of 1 mL/min.The detection wavelength was 290 nm. The retention time was found to be 4.573 min for lornoxicam. The linearity of the method has been satisfied with Beer Lambert’s law in the concentration range of 5-25 µg/mL with a correlation coefficient of 0.9988. The mean recoveries assessed for lornoxicam were in the range of 100.39-101.86 %, indicating good accuracy of the method. The limit of detection and limit of quantification were found to be 0.03 and 0.11 µg/mL, respectively. The developed method has been statistically validated in accordance with ICH guidelines and found to be mass spectrometric compatible, simple, precise, and accurate with the prescribed values. Thus, the proposed method was successfully applied for the estimation of lornoxicam in routine quality control analysis of bulk, formulations and in dissolution samples.


Author(s):  
Bhupender Tomar ◽  
Ankita Sharma ◽  
Inder Kumar ◽  
Sandeep Jain ◽  
Pallavi Ahirrao

A simple, precise, and accurate reverse phase high performance liquid chromatographic method (RP-HPLC) was developed and validated for the estimation of the combination of 5- Fluorouracil (5-FU) and Imiquimod in active pharmaceutical ingredients (APIs). The method was carried out on Phenomenex C18 (250 × 4.6mm I.D., 5𝜇m) using isocratic elution mode. The mobile phase was used as Acetonitrile: 10mM potassium dihydrogen orthophosphate: triethylamine (40:59.9:0.1, v/v, pH 4.5 with orthophosphoric acid) and Water: ACN (50:50 v/v) was used as a diluent. The concentration of solvents was 1-20µg/ml and the volume of injection was 20µl with the flow rate of 1.2ml/min. The retention times for 5-FU and Imiquimod were found to be 1.9±0.5 and 6.6±0.5 min respectively. The absorption maxima of 5FU and Imiquimod were found 267nm and 227nm respectively. The method was validated as per ICH guidelines. All the data were found within the specified limits. The limit of detection (LOD) and limit of quantification (LOQ) of 5- Fluorouracil were found to be 0.015μg/mL and 0.048 μg/mL, respectively, and Imiquimod was found to be 0.078μg/mL and 0.237μg/mL, respectively. The method developed in the present study was found to be sensitive, specific, and precise and can be applied for the simultaneous estimation of 5-FU and Imiquimod.


INDIAN DRUGS ◽  
2013 ◽  
Vol 50 (05) ◽  
pp. 48-52
Author(s):  
A Lodhi ◽  
◽  
A Jain ◽  
B. Biswal

A validated high performance liquid chromatographic method was developed for the determination of chromium picolinate in pharmaceutical dosage forms. The analysis was performed at room temperature using a reversed-phase ODS, 5µm (250×4.6) mm column. The mobile phase consisted of acetonitrile: buffer (60:40 V/V) at a flow rate of 0.5 mL/min. The PDA-detector was set at 264 nm. The developed method showed a good linear relationship in the concentration range from 1.5 – 12.5 µg/mL with a correlation coefficient from 0.999. The limit of detection and limit of quantification were 0.0540513 and 0.1637919 µg/mL respectively.


2012 ◽  
Vol 9 (3) ◽  
pp. 1327-1331 ◽  
Author(s):  
A. Narendra ◽  
D. Deepika ◽  
M. Mathrusri Annapurna

A reverse phase LC method was developed for the determination of Brimonidine in eye drops. Chromatography was carried on an Inertsil ODS 3V column (C18) using a mixture of Octane 1- sulfonic acid sodium salt (0.02M) (pH 3.5 ± 0.05) and acetonitrile (64:36 v/v) as mobile phase at a flow rate of 1 mL/min with UV detection at 254 nm. The drug was eluted at 4.636 min. The detector response was linear in the concentration range of 0.4–72 μg/mL. The limit of detection and limit of quantification were found to be 0.0561 and 0.1848 μg/mL respectively. The proposed method was validated as per the ICH guidelines and can be applied for the routine analysis of Brimonidine in eye drops.


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (06) ◽  
pp. 63-68
Author(s):  
R. Raut ◽  
◽  
A. Patil ◽  
V. K Munipalli ◽  
M. Patel ◽  
...  

A simple precise and rapid Reverse Phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed for quantitative determination of Regorafenib in tablet dosage form. In this method Hypersil Gold (C18, 150mm× 4.6mm id, 3μ) column with mobile phase consisting of Trifluoroacetic acid (0.2% v/v) and Acetonitrile in the ratio of (50: 50 v/v) at 400C in an isocratic mode was used. The detection was carried out at 260 nm and 20μL injection volume was selected with the flow rate 1mL/min. The linearity range of Regorafenib shows concentration between 5-200 μg/mL. The regression coefficient obtained was 0.999. Retention time of Regorafenib was found to be 6.49 minutes. Acetonitrile and Water in the ratio of (3:1) was used as a diluent. The method was validated as per ICH guidelines and is simple, fast, accurate, precise and can be applied for routine quality control analysis of Regorafenib in tablet dosage form.


INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (09) ◽  
pp. 27-32
Author(s):  
V. S Reddy ◽  
◽  
T. E. G. K. Murthy ◽  
N Usha Rani ◽  
R. S Rao ◽  
...  

A simple, precise, accurate, reproducible, robust reverse phase high-performance liquid chromatographic method was developed for the simultaneous estimation of frovatriptan, almotriptan and zolmitriptan in bulk and pharmaceutical dosage forms. The method was validated as per ICH and FDA guidelines. Analysis of the drugs was performed on Phenomenex Chromosil C-18 (250 x 4.6 mm, 5 mc) column, in an isocratic mode employing methanol, acetonitrile and THF in the ratio of 46:50:04 (v/v/v) as mobile phase. UV-visible detector at 269 nm was found to be suitable for detection. Linearity was observed in the range of 40-100 ppm.The % recovery was found to be 99.51, 99.69 and 99.34 for frovatriptan, almotriptan and zolmitriptan respectively. The % RSD values for method precision was found to be 0.86, 0.65 and 1.28 for frovatriptan, almotriptan and zolmitriptan respectively. Limit of quantification (LOQ) and limit of detection (LOD) values were found to be 0.15, 0.08 and 0.09 ppm. and 0.05, 0.02, 0.03 for frovatriptan, almotriptan and zolmitriptan respectively.


Author(s):  
Sunkara Namratha ◽  
Vijayalakshmi A

Objective: Reversed-phase high-performance liquid chromatographic method (RP-HPLC) was developed for the assessment of lopinavir in the dosage form of tablet.Methods: Chromatogram was run through using Kromosil C18 4.5×150 mm using a mobile phase methanol: water of ratio 65:35% v/v with a rate of flow of 0.8 ml/min, measured by UV spectrometric detection at 265 nm. The method developed was validated in terms of precision, accuracy, linearity, and robustness parameters.Results: Retention time of lopinavir established at 2.482 min and percentage R.S.D of lopinavir found to be 1.0% and 0.5%, respectively. The method shows that good linearity range of 30–150 μg correlation coefficient of lopinavir was 0.997. The limit of detection was 2.97 and limit of quantification was 9.92, respectively. The percent purity of lopinavir was 99.87%.Conclusion: The suggested method (Rp-HPLC) for concurrent assay lopinavir was validated, which is appropriate method for the analysis oflopinavir quantitatively in tablet dosage forms and bulk.


Sign in / Sign up

Export Citation Format

Share Document