scholarly journals Comparative Study of Indonesian Seismic Codes Applied on Vertically Irregular RC Building in High Seismicity Region

Author(s):  
Muhammad Ibnu Syamsi ◽  
◽  
Taufiq Ilham Maulana ◽  
Hararya Widyantama ◽  
Muhammad Rezki Ian ◽  
...  

The Aceh earthquake suffering Indonesia in 2004, and some big ground motions afterward led the earthquake-resistant building standard provisions to be updated. The rise of ground motions increases the lateral forces, so reevaluating existing buildings is needed, especially for Irregular buildings, which are more vulnerable than the regular ones. This study investigates the increase of earthquake loads and the building response in the high seismicity region due to the updated Indonesian code from SNI 1726:2002 to SNI 1726:2012. Building A in DI Yogyakarta with vertical irregularity on a certain floor is chosen as the object to be studied. There are two types of seismic loads to be simulated, response spectrum and time history analysis. The building is simulated using the numerical program, and four ground motion histories are selected for the dynamic exiting forces. The analysis result shows an increase in the story force either in the response spectrum or the time history. By taking the building's top floor as the reference point, the increase in lateral displacement is also detected in both response spectrum and time history analysis. From the interstory drift ratio examinations, it is also found that there is a weak point located on the setback part that is not identified just by observing the total displacement. This paper compiles the comparison of two versions of the Indonesian seismic code, two types of seismic force, and two points of view in analyzing the building response. Furthermore, the result presented in this paper also beneficial for mitigating the building.

2009 ◽  
Vol 25 (3) ◽  
pp. 583-605 ◽  
Author(s):  
Wei Chiang Pang ◽  
David V. Rosowsky

This paper presents a direct displacement design (DDD) procedure that can be used for seismic design of multistory wood-framed structures. The proposed procedure is applicable to any pure shear deforming system. The design procedure is a promising design tool for performance-based seismic design since it allows consideration of multiple performance objectives (e.g., damage limitation, safety requirements) without requiring the engineer to perform a complex finite element or nonlinear time-history analysis of the complete structure. A simple procedure based on normalized modal analysis is used to convert the code-specified acceleration response spectrum into a set of interstory drift spectra. These spectra can be used to determine the minimum stiffness required for each floor based on the drift limit requirements. Specific shear walls can then be directly selected from a database of backbone curves. The procedure is illustrated on the design of two three-story ATC-63 archetype buildings, and the results are validated using nonlinear time-history analysis.


2012 ◽  
Vol 166-169 ◽  
pp. 2164-2170
Author(s):  
Xu Jie Sun ◽  
Hou Zhang ◽  
Da Gang Lu ◽  
Feng Lai Wang

The design process of the 100 m high reinforced concrete masonry building in China was firstly presented, deformation check calculation under earthquake action by mode-superposition response spectrum method and time-history analysis method were detailed and deformation under wind load was also checked. Then elastic-plastic deformation under earthquake action was checked by time-history analysis method and pushover analysis method with both under uniform load and reverse triangle load. The conclusion is construct 100 m high office building built in Fortification intensity 6 by reinforced concrete masonry is feasible. Then the building was redesigned as built in fortification 7, the same check was performed as that have been done in fortification 6, it is feasible too.


2020 ◽  
Vol 2020 ◽  
pp. 1-14
Author(s):  
Rui Zhang ◽  
Dong-sheng Wang ◽  
Xiao-yu Chen ◽  
Hong-nan Li

In recent studies, spectral matching is the most commonly proposed method for selecting earthquake records for time-history analysis of structures. However, until now, there have been no serious investigations of the effects of coordinate values on the scaling of ground motions. This paper investigated the influence of using arithmetic and logarithmic values of response spectra in spectral matching procedures (i.e., ASM and LSM methods) on the results of nonlinear structural time-history analysis. Steel moment resisting frame structures of the 3-, 9-, and 20-stories, which represent low-, medium-, and high-rise buildings, respectively, were used as examples. Structural benchmark responses were determined by calculating the arithmetic mean and median of peak interstory drift ratio (PIDR) demands based on the three record sets developed by the American SAC Steel Project. The three record sets represent seismic hazard levels with 50%, 10%, and 2% probabilities exceeded in 50 years, and their average acceleration spectra were also taken as the target spectrum. Moreover, another 40 record components for selection were scaled both by ASM and LSM methods. The seven components whose spectra were best compatible with the target spectra were selected for the structural time-history analysis. The scale factors obtained by the LSM method are nearly larger than that of the ASM method, and their ranking and selection of records are different. The estimation accuracies of structural mean (median) responses by both methods can be controlled within an engineering acceptable range (±20%), but the LSM method may cause larger structural responses than the ASM method. The LSM method has a better capacity for reducing the variability of structural responses than the ASM method, and this advantage is more significant for longer-period structures (e.g., 20-story structure) with more severe nonlinear responses.


2020 ◽  
Vol 10 (18) ◽  
pp. 6210
Author(s):  
Ruihao Zheng ◽  
Chen Xiong ◽  
Xiangbin Deng ◽  
Qiangsheng Li ◽  
Yi Li

This study presents a machine learning-based method for the destructive power assessment of earthquake to structures. First, the analysis procedure of the method is presented, and the backpropagation neural network (BPNN) and convolutional neural network (CNN) are used as the machine learning algorithms. Second, the optimized BPNN architecture is obtained by discussing the influence of a different number of hidden layers and nodes. Third, the CNN architecture is proposed based on several classical deep learning networks. To build the machine learning models, 50,570 time-history analysis results of a structural system subjected to different ground motions are used as training, validation, and test samples. The results of the BPNN indicate that the features extraction method based on the short-time Fourier transform (STFT) can well reflect the frequency-/time-domain characteristics of ground motions. The results of the CNN indicate that the CNN exhibits better accuracy (R2 = 0.8737) compared with that of the BPNN (R2 = 0.6784). Furthermore, the CNN model exhibits remarkable computational efficiency, the prediction of 1000 structures based on the CNN model takes 0.762 s, while 507.81 s are required for the conventional time-history analysis (THA)-based simulation. Feature visualization of different layers of the CNN reveals that the shallow to deep layers of the CNN can extract the high to low-frequency features of ground motions. The proposed method can assist in the fast prediction of engineering demand parameters of large-number structures, which facilitates the damage or loss assessments of regional structures for timely emergency response and disaster relief after earthquake.


2005 ◽  
Vol 128 (3) ◽  
pp. 364-369 ◽  
Author(s):  
Y. M. Parulekar ◽  
G. R. Reddy ◽  
K. K. Vaze ◽  
K. Muthumani

Passive energy dissipating devices, such as elastoplastic dampers (EPDs) can be used for eliminating snubbers and reducing the response of piping systems subjected to seismic loads. Cantilever and three-dimensional piping systems were tested with and without EPD on shaker table. Using a finite element model of the piping systems, linear and nonlinear time-history analysis is carried out using Newmark’s time integration technique. Equivalent linearization technique, such as Caughey method, is used to evaluate the equivalent damping of the piping systems supported on elastoplastic damper. An iterative response spectrum method is used for evaluating response of the piping system using this equivalent damping. The analytical maximum response displacement obtained at the elastoplastic damper support for the two piping systems is compared with experimental values and time history analysis values. It has been concluded that the iterative response spectrum technique using Caughey equivalent damping is simple and results in reasonably acceptable response of the piping systems supported on EPD.


2013 ◽  
Vol 351-352 ◽  
pp. 849-853
Author(s):  
Lan Chen ◽  
De Long Lu ◽  
Xiao Gang Yin

Based on the vertical seismic information, the vertical seismic response spectrum was calculated by Matlab Lsim function. The seismic effect of Kiewitt-Lamella suspended-dome was measured by dynamic to static ratio. According to the EL-Centro seismic wave, it analyzed and compared the dynamic to static ratios which were calculated by the following four vertical seismic calculation methods respectively: the simplified method of specification, the mode-superposition response spectrum methods based on the horizontal earthquake affecting coefficients and the vertical acceleration response spectrum respectively, and the time history analysis method. Analysis shows that: For the seismic effect, the time history analysis method is larger than the other three methods, and the method based on the vertical acceleration response spectrum is closer to the time history analysis method. Owing to large difference of the four methods for seismic effect, various methods should be adopted to ensure the safety of vertical seismic design.


2017 ◽  
Author(s):  
George Wang ◽  
Michelle Loh ◽  
Yen-Tun Peng ◽  
Joanne Shen ◽  
P. E. Genesis ◽  
...  

2011 ◽  
Vol 243-249 ◽  
pp. 3988-3991 ◽  
Author(s):  
Pei Ju Chang ◽  
Jian Zhu

This study focus on derivation of such fragility curves using classic mid-story isolation and reduction structures (MIRS) in China metropolis. A set of stochastic earthquake waves compatible with the response spectrum of China seismic code selected to represent the variability in ground motion. Dynamic inelastic time history analysis was used to analyze the random sample of structures. The result reveal that good effect for superstructure and reduction effect for substructure of MIRS is favorable and obvious under major earthquake, Weak position of MIRS was be pointed out and fragility curves of typical MIRS of China was obtained finally.