scholarly journals Sistem Pendukung Keputusan Pemilihan Kualitas Produk UPS Terbaik Menggunakan Metode Topsis dan SAW

2021 ◽  
Vol 6 (1) ◽  
pp. 55
Author(s):  
Dimas Fathulyaqin ◽  
Ucuk Darusalam ◽  
Ira Diana Sholihati

<p><em>Every electronic device requires a good power supply so it perform functionally needed. Many devices use electrical energy. Starting from a laptop or computer device, TV, AC, refrigerator, cellphone, lights all use electric power. Even in every agency or company requires electrical energy for work activities to be more optimal. UPS</em><em> </em><em>(Uninterruptible Power Supply)</em><em> itself is very useful for protecting electronic devices from blackouts that can occur at any time. This tool stores electrical energy such as battery and re-flows it, so that devices such as computers are not damaged. By using the calculation algorithm method TOPSIS (Technique For Others Reference by Similarity to Ideal Solution) and SAW (Simple Additive Weighting) in making the best UPS quality decisions in terms of quality of goods by considering the quality of weight with the following criteria: Price, Capacity (VA), Capacity (Watts) and Runtime at 60W (min).</em></p>


2020 ◽  
Vol 1 ◽  
Author(s):  
Waylon J. Hastings ◽  
Dan T.A. Eisenberg ◽  
Idan Shalev

Abstract Technical challenges associated with telomere length (TL) measurements have prompted concerns regarding their utility as a biomarker of aging. Several factors influence TL assessment via qPCR, the most common measurement method in epidemiological studies, including storage conditions and DNA extraction method. Here, we tested the impact of power supply during the qPCR assay. Momentary fluctuations in power can affect the functioning of high-performance electronics, including real-time thermocyclers. We investigated if mitigating these fluctuations by using an uninterruptible power supply (UPS) influenced TL assessment via qPCR. Samples run with a UPS had significantly lower standard deviation (p < 0.001) and coefficient of variation (p < 0.001) across technical replicates than those run without a UPS. UPS usage also improved exponential amplification efficiency at the replicate, sample, and plate levels. Together these improvements translated to increased performance across metrics of external validity including correlation with age, within-person correlation across tissues, and correlation between parents and offspring.



Sign in / Sign up

Export Citation Format

Share Document