scholarly journals Low Dose Computed Tomography in Diagnosis of Ureteric Calculus in Obese Patients

2020 ◽  
Vol 9 (1) ◽  
pp. 27-31
Author(s):  
Mahesh Gautam ◽  
Aziz Ullah ◽  
Manish Raj Pathak

Background: Standard dose computed tomography is standard imaging modality in diagnosis of urolithiasis. The introduction of low dose techniques results in decrease radiation dose without significant change in image quality. However, the image quality of low dose computed tomography is affected by skin fold thickness and subcutaneous abdominal adipose tissue. The aim of this study to evaluate stone location, size, and density using low dose computed tomography compared with standard dose computed tomography in obese population. Material and Methods: This non-randomized non-inferiority trial includes 120 patient having BMI≥25kg/m2 with acute ureteric colic. The low dose and standard dose computed tomography were performed accordingly. Effective radiation doses were calculated from dose-length product obtained from scan report using conversion factor of 0.015. The images were reconstructed using iterative reconstruction algorithm. Effective dose, number and size of stone, Hounsfield Unit value of stone and image quality was assessed. Results: Stones were located in 69 (57.5%) in right and 51 (42.5%) in left ureter. There was no statistical difference in mean diameter, number and density of stones in low dose as compared with standard dose. The radiation dose was significantly lower with low dose. (3.68 mSv) The delineation of the ureter, outline of the stones and image quality in low dose was overall sufficient for diagnosis. No images of low dose scan were subjectively rated as non-diagnostics. Conclusion: Low dose computed tomography with iterative reconstruction technique is as effective as standard dose in diagnosis of ureteric stones in obese patients with lower effective radiation dose.

2021 ◽  
pp. 028418512198995
Author(s):  
Erdal Tekin ◽  
Kutsi Tuncer ◽  
Ibrahim Ozlu ◽  
Recep Sade ◽  
Rustem Berhan Pirimoglu ◽  
...  

Background The use and frequency of computed tomography (CT) are increasing day by day in emergency departments (ED). This increases the amount of radiation exposed. Purpose To evaluate the image quality obtained by ultra-low-dose CT (ULDCT) in patients with suspected wrist fractures in the ED and to investigate whether it is an alternative to standard-dose CT (SDCT). Material and Methods This is a study prospectively examining 336 patients who consulted the ED for wrist trauma. After exclusion criteria were applied, the patients were divided into the study and control groups. Then, SDCT (120 kVp and 100 mAs) and ULDCT (80 kVp and 5 mAs) wrist protocols were applied simultaneously. The images obtained were evaluated for image quality and fracture independently by a radiologist and an emergency medical specialist using a 5-point scale. Results The effective radiation dose calculated for the control group scans was 41.1 ± 2.1 µSv, whereas the effective radiation dose calculated for the study group scans was 0.5 ± 0.0 µSv. The effective radiation dose of the study group was significantly lower than that of the control group ( P < 0.01). The CT images in the study group showed no significant differences in the mean image quality score between observer 1 and observer 2 (3.4 and 4.3, respectively; P = 0.58). Both observers could detect all fractures using the ULDCT images. Conclusion ULDCT provides high-quality images in wrist traumas while reducing the radiation dose by approximately 98% compared to SDCT without any changes in diagnostic accuracy.


2017 ◽  
Vol 59 (8) ◽  
pp. 1002-1009 ◽  
Author(s):  
Ju Hee Ahn ◽  
Seung Ho Kim ◽  
Seung Jin Kim ◽  
In Chul Nam ◽  
Sung Jae Lee ◽  
...  

Background Repeated computed tomography (CT) scans may be an issue in young adults with urinary stones. Therefore, it is important to know how far the dose can be reduced while maintaining the diagnostic performance. Purpose To generate a hypothesis that it is feasible to decrease the radiation dose to a sub-millisievert (mSv) level with the addition of advanced modeled iterative reconstruction (ADMIRE) while maintaining the sensitivity to standard-dose CT (SDCT) for the detection of urinary stones. Material and Methods Ninety-two consecutive patients with urinary stones underwent non-enhanced CT that consisted of standard (120 kVp, 200 mAs) and lose-dose (LDCT) (80 kVp, 60 mAs). The LDCT images were reconstructed separately with five different strengths of ADMIRE (hereafter, S1–S5) and filtered back projection (FBP). Two blinded radiologists independently recorded a number of urinary stones in the six LDCT datasets and SDCT. The sensitivity of each set for detecting urinary stones was compared using the McNemar test. Results A total of 240 urinary stones were analyzed. The sensitivities of the six LDCT datasets showed no difference (FBP, S1–S5, for reader 1: 78%, 79%, 79%, 80%, 80%, and 80%; for reader 2: 64%, 63%, 64%, 64%, 65%, and 66%, P > 0.05, respectively), which were lower than those of SDCT for both readers (reader 1: 88%; reader 2: 81%, P < 0.0001, respectively). Conclusion Despite the addition of ADMIRE, it may not be feasible to decrease the radiation dose to a sub-mSv level while maintaining the sensitivity to SDCT for the detection of urinary stones.


2017 ◽  
Vol 59 (6) ◽  
pp. 740-747
Author(s):  
Marie-Louise Aurumskjöld ◽  
Marcus Söderberg ◽  
Fredrik Stålhammar ◽  
Kristina Vult von Steyern ◽  
Anders Tingberg ◽  
...  

Background In pediatric patients, computed tomography (CT) is important in the medical chain of diagnosing and monitoring various diseases. Because children are more radiosensitive than adults, they require minimal radiation exposure. One way to achieve this goal is to implement new technical solutions, like iterative reconstruction. Purpose To evaluate the potential of a new, iterative, model-based method for reconstructing (IMR) pediatric abdominal CT at a low radiation dose and determine whether it maintains or improves image quality, compared to the current reconstruction method. Material and Methods Forty pediatric patients underwent abdominal CT. Twenty patients were examined with the standard dose settings and 20 patients were examined with a 32% lower radiation dose. Images from the standard examination were reconstructed with a hybrid iterative reconstruction method (iDose4), and images from the low-dose examinations were reconstructed with both iDose4 and IMR. Image quality was evaluated subjectively by three observers, according to modified EU image quality criteria, and evaluated objectively based on the noise observed in liver images. Results Visual grading characteristics analyses showed no difference in image quality between the standard dose examination reconstructed with iDose4 and the low dose examination reconstructed with IMR. IMR showed lower image noise in the liver compared to iDose4 images. Inter- and intra-observer variance was low: the intraclass coefficient was 0.66 (95% confidence interval = 0.60–0.71) for the three observers. Conclusion IMR provided image quality equivalent or superior to the standard iDose4 method for evaluating pediatric abdominal CT, even with a 32% dose reduction.


2013 ◽  
Vol 42 (7) ◽  
pp. 937-945 ◽  
Author(s):  
Fabio Becce ◽  
Yosr Ben Salah ◽  
Francis R. Verdun ◽  
Bruno C. Vande Berg ◽  
Frederic E. Lecouvet ◽  
...  

2018 ◽  
Vol 185 (1) ◽  
pp. 17-26 ◽  
Author(s):  
Abdulaziz A Qurashi ◽  
Louise A Rainford ◽  
Khalid M Alshamrani ◽  
Shane J Foley

Abstract The aim of this study was to evaluate how iterative reconstruction can compensate for the noise increase in low radiation dose abdominal computed tomography (CT) technique for large size patients and the general impact of obesity on abdominal organ doses and image quality in CT. An anthropomorphic phantom layered with either none or a single layer of 3-cm- thick circumferential animal fat packs to simulate obese patients was imaged using a 128MDCT scanner. Abdominal protocols (n = 12) were applied using automatic tube current modulation (ATCM) with various quality reference mAs (150, 200, 250 and 300). kVs of 100, 120 and 140 were used for each mAs selection. Metal oxide semiconductor field effect transistor dosimeters (MOSFET) measured internal organ dose. All images produced were reconstructed with filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE) (3, 4 and 5) and objective noise was measured within three regions of interest at the level of L4–L5. Organ doses varied from 0.12 to 41.9 mGy, the spleen received the highest doses for both phantom sizes. Compared to the phantom simulating average size, the obese phantom was associated with up to twofold increase in delivered mAs, dose length product (DLP) and computed tomography dose index (CTDIvol) for the matched mAs selection (p < 0.05). However, organ dose increased by 50% only. The use of 100 kV resulted in a 40% lower dose (p < 0.05) compared to 120 kV and the associated noise increase was improved by SAFIRE (5) use, which resulted in 60% noise reduction compared to FBP (p < 0.05). When combined with iterative reconstruction, low kV is feasible for obese patients to optimise radiation dose and maintain objective image quality.


2015 ◽  
Vol 204 (6) ◽  
pp. 1197-1202 ◽  
Author(s):  
Yookyung Kim ◽  
Yoon Kyung Kim ◽  
Bo Eun Lee ◽  
Seok Jeong Lee ◽  
Yon Ju Ryu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document