scholarly journals Development of a New Heating System by Combining Superheated Steam and a Hot Water Spray (Aqua-Gas) and Its Application to Food Processing

2011 ◽  
Vol 58 (8) ◽  
pp. 351-358 ◽  
Author(s):  
Seiichiro Isobe ◽  
Yukio Ogasahara ◽  
Yukiko Negishi ◽  
Fumiko Tonozuka
2016 ◽  
Vol 63 (2) ◽  
pp. 86-92
Author(s):  
Kazunori Sasaki ◽  
Itaru Sotome ◽  
Hiroshi Okadome ◽  
Yumi Kai ◽  
Tomoyuki Oki ◽  
...  

2009 ◽  
Vol 10 (3) ◽  
pp. 163-173 ◽  
Author(s):  
Itaru SOTOME ◽  
Yukio OGASAWARA ◽  
Yoshitaka NADACHI ◽  
Makiko TAKENAKA ◽  
Hiroshi OKADOME ◽  
...  

LWT ◽  
2009 ◽  
Vol 42 (6) ◽  
pp. 1035-1040 ◽  
Author(s):  
Itaru Sotome ◽  
Makiko Takenaka ◽  
Shigenobu Koseki ◽  
Yukio Ogasawara ◽  
Yoshitaka Nadachi ◽  
...  

Foods ◽  
2021 ◽  
Vol 10 (7) ◽  
pp. 1490
Author(s):  
Wei Wang ◽  
Lu Dong ◽  
Yan Zhang ◽  
Huaning Yu ◽  
Shuo Wang

In order to reduce the formation of heterocyclic amines in grilled beef patties without destroying their unique quality characteristics, the effects of different thermal processes, including charcoal grilling, infrared grilling, superheated steam roasting and microwave heating, on the production of heterocyclic amines in beef patties and grilling quality characteristics were systematically analyzed. The results showed that infrared grilling can significantly (p < 0.05) reduce the content of heterocyclic amines in grilled patties, and the combination of microwave heating or superheated steam roasting with infrared grilling could further reduce the content of heterocyclic amines, with a maximum reduction ratio of 44.48%. While subtle differences may exist in infrared grilled patties with/without superheated steam roasting or microwave heating, a slight change will not affect the overall quality characteristics of grilled patties. The combined thermal processing will not visually affect the color of the grilled patties. Correlation analysis and regression analysis showed that the reduction in heterocyclic amines caused by microwave heating and superheated steam roasting are related to the moisture content and lipid oxidation of grilled patties, respectively. Using combined thermal processes to reduce the formation of heterocyclic amines is advisable.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3350
Author(s):  
Theofanis Benakopoulos ◽  
William Vergo ◽  
Michele Tunzi ◽  
Robbe Salenbien ◽  
Svend Svendsen

The operation of typical domestic hot water (DHW) systems with a storage tank and circulation loop, according to the regulations for hygiene and comfort, results in a significant heat demand at high operating temperatures that leads to high return temperatures to the district heating system. This article presents the potential for the low-temperature operation of new DHW solutions based on energy balance calculations and some tests in real buildings. The main results are three recommended solutions depending on combinations of the following three criteria: district heating supply temperature, relative circulation heat loss due to the use of hot water, and the existence of a low-temperature space heating system. The first solution, based on a heating power limitation in DHW tanks, with a safety functionality, may secure the required DHW temperature at all times, resulting in the limited heating power of the tank, extended reheating periods, and a DH return temperature of below 30 °C. The second solution, based on the redirection of the return flow from the DHW system to the low-temperature space heating system, can cool the return temperature to the level of the space heating system return temperature below 35 °C. The third solution, based on the use of a micro-booster heat pump system, can deliver circulation heat loss and result in a low return temperature below 35 °C. These solutions can help in the transition to low-temperature district heating.


2012 ◽  
Vol 193-194 ◽  
pp. 30-33
Author(s):  
Xue Ying Wang ◽  
Dong Xu ◽  
Ya Jun Wu

This article analyzes the problem in application the solar system was used in residential building, puts forward the requirements to use energy and choose the setting of the solar energy collector from two aspects of building and drainage design respectively. In addition, the article explicates andthe solar energy collector and building integrated design and the development of solar energy collector. At last, the article puts forward some Suggestions on the improvement and development of residential solar hot water system and the design of the hot water supply bath solution of practice to make solar energy and low power assisted by night combining.


2013 ◽  
Vol 315 ◽  
pp. 783-787
Author(s):  
M.Yaakob Yuhazri ◽  
A.M. Kamarul ◽  
A.H. Rahimah ◽  
Sihombing Haeryip ◽  
S.H. Yahaya

This research is related to thermal efficient water heating system, specifically to improve the water heating system that exists nowadays. The goal of this research is to improve the current water heating system by using solar heat as the energy source to heat the water. The focus is to improve the thermal efficiency by adding different thermal boxes as the absorber bed. By implementing the black body and radiation concept, the air trapped in the box is heated. The trapped air then increases the collisions between the molecules and directly increases the temperature inside the box, higher than the outside environment. Based on a daytime experimental result revealed steel thermal box is better to be used for tropical weather like Malaysia.


Author(s):  
Andy Walker ◽  
Fariborz Mahjouri ◽  
Robert Stiteler

This paper describes design, simulation, construction and measured initial performance of a solar water heating system (360 Evacuated Heat-Pipe Collector tubes, 54 m2 gross area, 36 m2 net absorber area) installed at the top of the hot water recirculation loop in the Social Security Mid-Atlantic Center in Philadelphia. Water returning to the hot water storage tank is heated by the solar array when solar energy is available. This new approach, as opposed to the more conventional approach of preheating incoming water, is made possible by the thermal diode effect of heat pipes and low heat loss from evacuated tube solar collectors. The simplicity of this approach and its low installation costs makes the deployment of solar energy in existing commercial buildings more attractive, especially where the roof is far removed from the water heating system, which is often in the basement. Initial observed performance of the system is reported. Hourly simulation estimates annual energy delivery of 111 GJ/year of solar heat and that the annual efficiency (based on the 54 m2 gross area) of the solar collectors is 41%, and that of the entire system including parasitic pump power, heat loss due to freeze protection, and heat loss from connecting piping is 34%. Annual average collector efficiency based on a net aperture area of 36 m2 is 61.5% according to the hourly simulation.


1985 ◽  
Vol 1 (2) ◽  
pp. 60-63
Author(s):  
L. Bynum Driggers ◽  
Rupert W. Watkins

Sign in / Sign up

Export Citation Format

Share Document