General Measurement Methodology

2017 ◽  
pp. 51-65
Author(s):  
Matthias Wagner
TAPPI Journal ◽  
2012 ◽  
Vol 11 (8) ◽  
pp. 51-58
Author(s):  
ANTTI HAAPALA ◽  
MIKA KÖRKKÖ ◽  
ELISA KOIVURANTA ◽  
JOUKO NIINIMÄKI

Analysis methods developed specifically to determine the presence of ink and other optically active components in paper machine white waters or other process effluents are not available. It is generally more interest¬ing to quantify the effect of circulation water contaminants on end products. This study compares optical techniques to quantify the dirt in process water by two methods for test media preparation and measurement: direct process water filtration on a membrane foil and low-grammage sheet formation. The results show that ink content values obtained from various analyses cannot be directly compared because of fundamental issues involving test media preparation and the varied methodologies used to formulate the results, which may be based on different sets of assumptions. The use of brightness, luminosity, and reflectance and the role of scattering measurements as a part of ink content analysis are discussed, along with fine materials retention and measurement media selection. The study concludes with practical tips for case-dependent measurement methodology selection.


2013 ◽  
Vol 18 (2-3) ◽  
pp. 33-41
Author(s):  
Dominik Sankowski ◽  
Marcin Bakala ◽  
Rafał Wojciechowski

Abstract The good quality of several manufactured components frequently depends on solidliquid interactions existing during processing. Nowadays, the research in material engineering focuses also on modern, automatic measurement methods of joining process properties, i.a. wetting force and surface tension, which allows for quantitative determination of above mentioned parameters. In the paper, the brazes’ dynamic properties in high-temperatures’ measurement methodology and the stand for automatic determination of braze’s properties, constructed and implmented within the research grant nr KBN N N519 441 839 - An integrated platform for automatic measurement of wettability and surface tension of solders at high temperatures, are widely described


Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 895
Author(s):  
Adam Szeleziński ◽  
Adam Muc ◽  
Lech Murawski ◽  
Marcin Kluczyk ◽  
Tomasz Muchowski

The paper presents the measurement process and test results for six thin-walled plates with different dynamic characteristics caused by different defects of welded joints. The tests were carried out using non-destructive testing (NDT). The authors made an attempt to determine the validity of the use and degree of effectiveness of the tests based on laser vibrometry in detecting defects in welded joints. The tests of welded plates were carried out using displacement laser sensors and piezoelectric accelerometers, while the source of vibration extortion was a modal hammer. In the adopted measurement methodology, the application of accelerometers was to obtain the reference data, which allowed for comparison with the measurement data obtained from the laser vibrometer. The analysis of the obtained measurement data, in the fields of time and frequency, made it possible to verify the correctness of the data obtained by means of laser vibrometry and to determine the requirements which are necessary for the correct performance of NDT tests and in the future structural health monitoring (SHM) system of welded joints with the use of a laser vibrometer. The mathematical model developed in the MSC software Pastran-Nastran was also used in the work. The model was developed for the purpose of mutual verification of the measurement and calculation tests. At the present stage of work, it can be stated that the results obtained by laser vibrometry methods should be treated as a supplement to the research conducted with traditional piezoelectric accelerometers. In certain situations, they can be used as an alternative to accelerometers, due to the fact that laser sensors do not require direct contact with the examined object. Where the object under test may be in a strong electromagnetic field, optical sensors are better suited than contact sensors.