scholarly journals A 4-Year Audit of Open Method Chemoport Insertions through Cephalic Vein Performed In Hospital Tengku Ampuan Afzan

2019 ◽  
Vol 18 (1) ◽  
Author(s):  
DS Sanjay ◽  
KY Lee ◽  
H Syafiq ◽  
MS Salleh

Introduction: Many cancer patients in general require long term venous access such as chemoport for chemotherapy, as well as infusion of fluids and blood taking. However, chemoport insertions carry complications such as infection, blockage, pneumothorax and malposition. We received feedbacks regarding complications endured by patients after chemoport insertion from the respective teams managing the patients in our hospital. In view of that, we conducted a retrospective audit on the chemoport insertions which we have done. Materials and Methods: We conducted a retrospective audit on the chemoport insertions which was planned for open method insertion through cephalic vein performed over the last 4 years from 2014 to 2017. Results: A total of 102 chemoports were inserted. Majority of patient’s ages are 50-59 years old. 88 (86%) of the cases were done via open method whereas another 14 cases were converted to percutaneous route. Majority of patients (55%) of the patients have breast carcinoma followed by colorectal (28%), haematological (12%) and gynaecological malignancies (5%). Complications occurred in 10 patients (rate at 9.8%). Most common complications were catheter related infection (5 cases) followed by wound infection (3 cases) and malposition (2 cases). Malposition was detected on post-operative chest radiograph and revision was done. All catheter related infection occurred in patients with haematological malignancies. Our complication rate of 9.8% is lower than the accepted complication rate of 15-25% worldwide. Conclusion: Chemoport provides a robust vascular access especially for the purpose of chemotherapy infusion. We showed with adequate training and privileging, it can be performed with very limited complications.

2021 ◽  
Vol 17 (1) ◽  
Author(s):  
Adriana Fernandes de Souza Garcia ◽  
Gesiane Ribeiro ◽  
Julia de Assis Arantes ◽  
Gustavo Morandini Reginato ◽  
Nathalia Villaca Xavier ◽  
...  

Abstract Background For horses requiring prolonged daily cephalic intravenous regional limb perfusion (IVRLP), the use of a totally implantable catheter (TIC) could be indicated to reduce complications associated with frequent venipuncture or external catheterization. This study aims to evaluate the implantation technique of the TIC in the cephalic vein of horses for IVRLP, describe the complications associated with the device’s placement and use, and assess its viability up to 60 days after implantation. Totally implantable catheters, cut to 15 cm (n = 5) and 46 cm (n = 5) in length, were implanted into one cephalic vein in ten adult horses (n = 10). Twenty-four hours following placement, IVRLP with contrast was performed via the TIC and evaluated with radiography. Physical examinations, lameness evaluation, hematologic assessment, and the catheter patency tests were performed at scheduled intervals for the duration of catheterization (7–60 days). Results Catheters were implanted without difficulty and allowed for IVRLP 24 h post implantation. Complications resulted in removal of the catheters, with four maintained for 7 days, three in place for 15 days, and three catheters maintained for 60 days. Complications included lameness, limb swelling, catheter kinking, and venous thrombosis. Conclusions The implantation technique of the TIC in the cephalic vein of horses is feasible and requires minimal technical effort. Although TIC allows venous access without the need for repeated venipuncture, its long-term use presents complications. For horses requiring prolonged daily cephalic IVRLP, the use of a TIC could be indicated. However, the high incidence of venous thrombosis may limit clinical application.


2019 ◽  
Vol 14 (12) ◽  
pp. 758-760
Author(s):  
Sanjay A Patel ◽  
Tiago Araujo ◽  
Luis Parra Rodriguez ◽  
Claudia Ramirez Sanchez ◽  
Ashley Snyder ◽  
...  

The risk of infectious and noninfectious complications associated with long peripheral catheters (LPCs) is unknown. In this retrospective study of 539 catheters, we found LPCs were often placed for the indications of difficult access and long-term antibiotics. Rates of deep vein thrombosis (1.7%) and catheter-related infection (0.6%) were low. LPCs may represent a novel and safe option for short-term venous access.


2021 ◽  
Vol 25 (47) ◽  
pp. 1-126
Author(s):  
Olivia Wu ◽  
Elaine McCartney ◽  
Robert Heggie ◽  
Evi Germeni ◽  
James Paul ◽  
...  

Background Venous access devices are used for patients receiving long-term chemotherapy. These include centrally inserted tunnelled catheters or Hickman-type devices (Hickman), peripherally inserted central catheters (PICCs) and centrally inserted totally implantable venous access devices (PORTs). Objectives To evaluate the clinical effectiveness, safety, cost-effectiveness and acceptability of these devices for the central delivery of chemotherapy. Design An open, multicentre, randomised controlled trial to inform three comparisons: (1) peripherally inserted central catheters versus Hickman, (2) PORTs versus Hickman and (3) PORTs versus peripherally inserted central catheters. Pre-trial and post-trial qualitative research and economic evaluation were also conducted. Setting This took place in 18 UK oncology centres. Participants Adult patients (aged ≥ 18 years) receiving chemotherapy (≥ 12 weeks) for either a solid or a haematological malignancy were randomised via minimisation. Interventions Hickman, peripherally inserted central catheters and PORTs. Primary outcome A composite of infection (laboratory confirmed, suspected catheter related and exit site infection), mechanical failure, venous thrombosis, pulmonary embolism, inability to aspirate blood and other complications in the intention-to-treat population. Results Overall, 1061 participants were recruited to inform three comparisons. First, for the comparison of peripherally inserted central catheters (n = 212) with Hickman (n = 212), it could not be concluded that peripherally inserted central catheters were significantly non-inferior to Hickman in terms of complication rate (odds ratio 1.15, 95% confidence interval 0.78 to 1.71). The use of peripherally inserted central catheters compared with Hickman was associated with a substantially lower cost (–£1553) and a small decrement in quality-adjusted life-years gained (–0.009). Second, for the comparison of PORTs (n = 253) with Hickman (n = 303), PORTs were found to be statistically significantly superior to Hickman in terms of complication rate (odds ratio 0.54, 95% confidence interval 0.37 to 0.77). PORTs were found to dominate Hickman with lower costs (–£45) and greater quality-adjusted life-years gained (0.004). This was alongside a lower complications rate (difference of 14%); the incremental cost per complication averted was £1.36. Third, for the comparison of PORTs (n = 147) with peripherally inserted central catheters (n = 199), PORTs were found to be statistically significantly superior to peripherally inserted central catheters in terms of complication rate (odds ratio 0.52, 95% confidence interval 0.33 to 0.83). PORTs were associated with an incremental cost of £2706 when compared with peripherally inserted central catheters and a decrement in quality-adjusted life-years gained (–0.018) PORTs are dominated by peripherally inserted central catheters: alongside a lower complications rate (difference of 15%), the incremental cost per complication averted was £104. The qualitative work showed that attitudes towards all three devices were positive, with patients viewing their central venous access device as part of their treatment and recovery. PORTs were perceived to offer unique psychological benefits, including a greater sense of freedom and less intrusion in the context of personal relationships. The main limitation was the lack of adequate power (54%) in the non-inferiority comparison between peripherally inserted central catheters and Hickman. Conclusions In the delivery of long-term chemotherapy, peripherally inserted central catheters should be considered a cost-effective option when compared with Hickman. There were significant clinical benefits when comparing PORTs with Hickman and with peripherally inserted central catheters. The health economic benefits were less clear from the perspective of incremental cost per quality-adjusted life-years gained. However, dependent on the willingness to pay, PORTs may be considered to be cost-effective from the perspective of complications averted. Future work The deliverability of a PORTs service merits further study to understand the barriers to and methods of improving the service. Trial registration This trial is registered as ISRCTN44504648. Funding This project was funded by the National Institute for Health Research (NHIR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 25, No. 47. See the NIHR Journals Library website for further project information.


1998 ◽  
Vol 2 (1) ◽  
pp. 38-40
Author(s):  
Franco Tesio ◽  
Hamurabi De Baz ◽  
Giacomo Panarello

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yuuki Iida ◽  
Kumiko Hongo ◽  
Takanobu Onoda ◽  
Yusuke Kita ◽  
Yukio Ishihara ◽  
...  

AbstractCentral venous port (CVP) is a widely used totally implantable venous access device. Recognition of risks associated with CVP-related complications is clinically important for safe, reliable, and long-term intravenous access. We therefore investigated factors associated with CVP infection and evulsion, including the device type. A total of 308 consecutive patients with initial CVP implantation between January 2011 and December 2017 were retrospectively reviewed, and the association of clinical features with CVP-related complications were analyzed. Intraoperative and postoperative complications occurred in 11 (3.6%) and 39 (12.7%) patients, respectively. The overall rate of CVP availability at six months was 91.4%. Malignancy and 2-Methacryloyloxyethyl phosphorylcholine (MPC) polymer-coated catheter use were negatively associated with the incidence of CVP infections. Accordingly, malignancy and MPC polymer-coated catheter use were independent predictors for lower CVP evulsion rate (odds ratio, 0.23 and 0.18, respectively). Furthermore, both factors were significantly associated with longer CVP availability (hazard ratio, 0.24 and 0.27, respectively). This retrospective study identified factors associated with CVP-related complications and long-term CVP availability. Notably, MPC polymer-coated catheter use was significantly associated with a lower rate of CVP infection and longer CVP availability, suggesting the preventive effect of MPC coating on CVP infection.


Sign in / Sign up

Export Citation Format

Share Document