scholarly journals Subcutaneous Implantable Cardioverter Defibrillator and LifeVest Saving Lives in Challenging Scenarios

Author(s):  
Domenico Facchin ◽  
Domenico Facchin ◽  
Tioni C ◽  
Daleffe E ◽  
Rebellato L ◽  
...  

Introduction: According to guidelines, ICD should be implanted in selected patients for primary or secondary prevention. The increasing number of procedures leads to a growth of infective complications. Case Summary: We report two cases of ICD implantation complicated with severe infections. The first procedure was complicated by endocarditis and septic shock, the second one by septic shock. After antibiotics and ICD explantation, a wearable cardioverter defibrillator (WCD) was used as a bridge to subcutaneous ICD (S-ICD). Conclusion: These two cases demonstrate the benefits of the S-ICD, but also the chance to treat high-risk patients with WCD as bridge-to-procedure, allowing full recovery before a new implantation.

2012 ◽  
Vol 8 (2) ◽  
pp. 134
Author(s):  
Vincent Floré ◽  
Rik Willems ◽  
◽  

Sudden cardiac death (SCD) is an important cause of mortality. In this article, we review the definition, impact and underlying aetiology of SCD. Ventricular tachyarrhythmia accounts for the majority of SCDs and can be caused by various underlying heart diseases, the most frequent being ischaemic cardiomyopathy. The most effective ways to reduce the risk of SCD in ischaemic cardiomyopathy are the optimal prevention of recurrent coronary ischaemia and the use of an implantable cardioverter-defibrillator (ICD) in high-risk patients. We discuss current patient selection for ICD implantation and focus on the need for, and possibilities to improve, SCD risk stratification.


Heart Rhythm ◽  
2005 ◽  
Vol 2 (5) ◽  
pp. S32 ◽  
Author(s):  
Ulf Meltendorf ◽  
Sven Reek ◽  
Frank Buhtz ◽  
Joerg Mittag ◽  
Stephan Hobrack ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
J Ehmsen ◽  
H Keller ◽  
C Stoellberger

Abstract Background The use of the Wearable Cardioverter Defibrillator (WCD) is recommended in national, European and American guidelines. However, there are almost exclusively data from the manufacturer's own data network. Independent data on the experience with the WCD are rare. Objective The aim of the retrospective study from one cardiologic department was to record efficiency, safety and compliance of the WCD. Patients and methods The study included all patients, to whom a WCD was described between 1.11.2010 and 1.5.2018 at one cardiologic department. Clinical data were obtained from the patients' records and the data about the WCD from the information network of the manufacturer. Results This study enrolled 66 patients, 51 males (77%) and 15 females (23%). The median age was 55 years (IQR: 45–63). They suffered from ischemic cardiomyopathy (n=33; 49%), dilated cardiomyopathy (n=12; 18%), myocarditis (n=7; 11%), explantation of an implantable cardioverter/defibrillator (ICD; n=5; 8%) and other indications (n=6; 9%). The median wearing time of the WCD was 73 days (interquartile range-IQR: 39–126), with median daily use of 22.91 h (IQR: 19.58–23.61). Among 38 patients with LVEF ≤35%, LVEF improved to ≥35% in 19 patients (50%) during WCD therapy. Over 1600 times the WCD detected a VT falsely. Four patients (8%) suffered from 212 non-sustained VT. One patient was successfully shocked because of ventricular fibrillation (appropriate shock rate: 1.5%). There were no inappropriate shocks. All patients, who wore the WCD, survived and one patient died when he did not wear the WCD. At the end of therapy 32 patients (48%) received an ICD. In terms of wearing time and events (shocks, arrhythmias, artifacts) there were no significant differences between patients receiving ICD and those who did not receive an ICD. Patients who received an ICD had a significantly lower LVEF after 3 months than patients who did not receive an ICD. Conclusion Our data confirm, that the WCD is safe and that the patients, who wear a WCD, have a high adherence. More than half of the patients with reduced LVEF improved their systolic function during WCD therapy, thus obviating the need for ICD implantation. Questions about the effectiveness of the detection algorithm remained open. Funding Acknowledgement Type of funding source: None


Circulation ◽  
2014 ◽  
Vol 130 (suppl_2) ◽  
Author(s):  
Chingping Wan ◽  
Steven J Szymkiewicz

Introduction: The wearable cardioverter defibrillator (WCD) has been used to protect AMI patients with reduced LVEF (≤35%) until ICD evaluation is recommended. The rate of EF improvement (e.g. EF>35%) over the initial 8-12 weeks after AMI has not been reported. METHODS: The manufacturer-maintained registry was searched for AMI patients who received a WCD shock for VT/VF between 05/2008 and 02/2013. The treated group was matched (1: ~4) with event-free WCD patients by ICD-9 code (410.*), gender, age and prescription date. Chart notes were reviewed for clinical characteristics. Follow-up was assessed through the registry and Social Security Death Master File. RESULTS: There were 992 (age=63±12, female=20.2%) AMI patients included in the final analysis, 206 treated by WCD and 786 event-free patients. Median follow-up was 334 days. Mean length of WCD use was 67±506 (median=38) days. Subgroup clinical characteristics are presented in Table 1. In the event-free group, 289 (38.9%) patients showed EF improvement to >35%. Nine (4.5%) in the treated group continued wearing the WCD until EF recovery, while 125 (60.7%) received ICD. Absence of recorded heart failure and/or diabetes were associated with LVEF recovery (p<.0001). CONCLUSION: In our study, almost 40% of AMI patients with initial EF ≤35% had EF improvement in two months. The EF recovery group had lower rates of heart failure and diabetes. WCD allows time for left ventricular function recovery in low EF post MI patients, optimizing ICD implantation decisions.


2014 ◽  
Vol 78 (12) ◽  
pp. 2987-2989 ◽  
Author(s):  
Shingo Sasaki ◽  
Hirofumi Tomita ◽  
Shuji Shibutani ◽  
Kei Izumiyama ◽  
Takumi Higuma ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document