scholarly journals Axial interbody arthrodesis of the L5–S1 segment: a systematic review of the literature

2015 ◽  
Vol 23 (3) ◽  
pp. 314-319 ◽  
Author(s):  
Gregory D. Schroeder ◽  
Christopher K. Kepler ◽  
MD MBA ◽  
Alexander R. Vaccaro

OBJECT The object of this study was to determine the fusion rate and safety profile of an axial interbody arthrodesis of the L5–S1 motion segment. METHODS A systematic search of MEDLINE was conducted for literature published between January 1, 2000, and August 17, 2014. All peer-reviewed articles related to the fusion rate of L5–S1 and the safety profile of an axial interbody arthrodesis were evaluated. RESULTS Seventy-four articles were identified, but only 15 (13 case series and 2 retrospective cohort studies) met the study inclusion criteria. The overall pseudarthrosis rate at L5–S1 was 6.9%, and the rate of all other complications was 12.9%. A total of 14.4% of patients required additional surgery, and the infection rate was 5.4%. Deformity studies reported a significantly increased rate of complications (46.3%), and prospectively collected data demonstrated significantly higher complication (36.8%) and revision (22.6%) rates. Lastly, studies with a conflict of interest reported lower complication rates (12.4%). CONCLUSIONS A systematic review of the literature indicates that an axial interbody fusion performed at the lumbosacral junction is associated with a high fusion rate (93.15%) and an acceptable complication rate (12.90%). However, these results are based mainly on retrospective case series by authors with a conflict of interest. The limited prospective data available indicate that the actual fusion rate may be lower and the complication rate may be higher than currently reported.

2017 ◽  
Vol 11 (3) ◽  
pp. 223-229 ◽  
Author(s):  
Zachariah W. Pinter ◽  
Kenneth S. Smith ◽  
Parke W. Hudson ◽  
Caleb W. Jones ◽  
Ryan Hadden ◽  
...  

Distal fibula fractures represent a common problem in orthopaedics. When fibula fractures require operative fixation, implants are typically made from stainless steel or titanium alloys. Carbon fiber implants have been used elsewhere in orthopaedics for years, and their advantages include a modulus of elasticity similar to that of bone, biocompatibility, increased fatigue strength, and radiolucency. This study hypothesized that carbon fiber plates would provide similar outcomes for ankle fracture fixation as titanium and steel implants. A retrospective chart review was performed of 30 patients who underwent fibular open reduction and internal fixation (ORIF). The main outcomes assessed were postoperative union rate and complication rate. The nonunion or failure rate for carbon fiber plates was 4% (1/24), and the union rate was 96% (23/24). The mean follow-up time was 20 months, and the complication rate was 8% (2/24). Carbon fiber plates are a viable alternative to metal plates in ankle fracture fixation, demonstrating union and complication rates comparable to those of traditional fixation techniques. Their theoretical advantages and similar cost make them an attractive implant choice for ORIF of the fibula. However, further studies are needed for extended follow-up and inclusion of larger patient cohorts. Levels of Evidence: Level IV: Retrospective Case series


2007 ◽  
Vol 4;10 (7;4) ◽  
pp. 541-546
Author(s):  
Sheldon E Jordan

Background: Botulinum chemodenervation has been increasingly used for treating conditions characterized by muscular pain and dystonia. Complication rates commonly exceed 10 percent in published accounts due to an inadvertent spread of toxin. Various techniques of precision targeting have been described to minimize undesirable toxin effects. The present study reports on a clinical experience combining ultrasonography and electromyography in order to demonstrate how favorably this approach compares to previously described techniques in terms of minimizing complications while maintaining efficacy. Design: Retrospective case series Methods: The present study is a retrospective clinical analysis of patients treated with botulinum toxin using 2 different combined targeting techniques; one using ultrasonography and electromyography and the other using fluoroscopy and electromyography. Results: Combined ultrasonography and electromyography was used in 77 of 245 procedures; in 168 procedures, fluoroscopy and electromyography was used. There were no complications with ultrasonography guided procedures; the complication rate for combined fluoroscopy and electromyography was 1.8 percent (3/168; Fisher exact p = 0.3206). For combined ultrasonography and electromyography, after 70 out of 77 procedures (91%) there was a good outcome compared to 136 out of 168 (81%) after procedures utilizing a combination of fluoroscopy and electromyography (Fisher exact p= 0.331). Conclusions: There was no significant difference in complication rate or successful outcomes comparing the 2 forms of imaging guidance when targeting muscles for botulinum injection. Since outcomes are comparable, other factors such as cost and radiation exposure may be considered in choosing which imaging modality to use. Key words: thoracic outlet syndrome, brachial plexus, botulinum toxin, ultrasound


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Vikram Ponnusamy ◽  
Van Nguyen ◽  
Jella A. An

Abstract Background To compare 6 month outcomes of bleb needling performed in the clinic vs. the operating room (OR) in adult glaucoma patients with failed bleb. Methods A retrospective case series of 47 eyes from 41 glaucoma patients who received needling with mitomycin C (MMC) of scarred bleb from prior bleb-forming procedures in clinic (32 eyes) vs. the OR (15 eyes), including trabeculectomy (14 eyes), ExPress shunt (16 eyes), and ab-interno XEN gel stent (17 eyes). The primary outcome was needling success, defined as IOP ≤ 18 mmHg on 0 glaucoma medications without requiring an additional IOP lowering procedure within 6 months after needling. Results At 6 months, bleb needling success rate was similar when performed in the clinic vs. in the OR (28% vs. 20%, P = 0.54). Success rate was not statistically different in patients with prior trabeculectomy, ExPress shunt, and XEN gel stent (29% vs. 38% vs. 12%, P = 0.26). When comparing clinic vs. the OR needling procedures at 6 months, there was no difference in mean IOP (14.2 vs. 14.9 mmHg, P = 0.73), mean glaucoma medications (1.4 vs. 1.7, P = 0.69), additional IOP-lowering procedure rate (16% vs. 27%, P = 0.37), or complication rate (0% vs. 7%, P = 0.32). Conclusion Bleb needling with MMC in clinic may be a safe and effective way to revise failed bleb after trabeculectomy, ExPress shunt, and XEN gel stent procedures when compared to needling in the OR.


2021 ◽  
pp. 219256822199478
Author(s):  
Karim Shafi ◽  
Francis Lovecchio ◽  
Maria Sava ◽  
Michael Steinhaus ◽  
Andre Samuel ◽  
...  

Study Design: Retrospective case series. Objective: To report contemporary rates of complications and subsequent surgery after spinal surgery in patients with skeletal dysplasia. Methods: A case series of 25 consecutive patients who underwent spinal surgery between 2007 and 2017 were identified from a single institution’s skeletal dysplasia registry. Patient demographics, medical history, surgical indication, complications, and subsequent surgeries (revisions, extension to adjacent levels, or for pathology at a non-contiguous level) were collected. Charlson comorbidity indices were calculated as a composite measure of overall health. Results: Achondroplasia was the most common skeletal dysplasia (76%) followed by spondyloepiphyseal dysplasia (20%); 1 patient had diastrophic dysplasia (4%). Average patient age was 53.2 ± 14.7 years and most patients were in excellent cardiovascular health (88% Charlson Comorbidity Index 0-4). Mean follow up after the index procedure was 57.4 ± 39.2 months (range). Indications for surgery were mostly for neurologic symptoms. The most commonly performed surgery was a multilevel thoracolumbar decompression without fusion (57%). Complications included durotomy (36%), neurologic complication (12%), and infection requiring irrigation and debridement (8%). Nine patients (36%) underwent a subsequent surgery. Three patients (12%) underwent a procedure at a non-contiguous anatomic zone, 3 (12%) underwent a revision of the previous surgery, and another 3 (12%) required extension of their previous decompression or fusion. Conclusions: Surgical complication rates remain high after spine surgery in patients with skeletal dysplasia, likely attributable to inherent characteristics of the disease. Patients should be counseled on their risk for complication and subsequent surgery.


2021 ◽  
pp. 194338752110264
Author(s):  
Sean A. Knudson ◽  
Kristopher M. Day ◽  
Patrick Kelley ◽  
Pablo Padilla ◽  
Ian X. Collier ◽  
...  

Study Design: Retrospective case series; systematic review. Objective: It is unknown whether the use of virtual surgical planning (VSP) to facilitate same-admission microsurgical reconstruction of the mandible following acute maxillofacial ballistic trauma (MBT) is sufficient to achieve definitive reconstruction and functional occlusion. Methods: A single-center retrospective analysis was conducted for patients who underwent microsurgical reconstruction of the mandible using VSP after acute MBT. The PubMed/MEDLINE, Embase, ScienceDirect, and Scopus databases were systematically reviewed using blinded screening. Studies were evaluated via thematic analysis. Results: Five patients were treated by same-admission and microsurgical reconstruction of the mandible using VSP. We observed an average of 16.4 ± 9.1 days between initial presentation and reconstruction, an average length of stay of 51.6 ± 17.9 days, 6.2 ± 2.8 operations, and 1.6 ± 0.9 free flaps per patient. Four types and 8 total flaps were employed, most commonly the anterior lateral thigh flap (37.5%). Care yielded complete flap survival. Each patient experienced at least 1 minor complication. All patients achieved centric occlusion, oral nutrition, and an approximation of their baseline facial aesthetic. Follow up was 191.0 ± 183.9 weeks. Systematic review produced 8 articles that adhered to inclusion criteria. Consensus themes in the literature were found for clinical goal and function of VSP when practicing MBT reconstruction, yet disagreement was found surrounding optimal treatment timeline. Conclusions: Same-admission microsurgical reconstruction after MBT is safe and effective to re-establish mandibular form and function. VSP did not delay reconstruction, given the need for preparation prior to definitive reconstruction.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Matteo Buda ◽  
Riccardo D’Ambrosi ◽  
Enrico Bellato ◽  
Davide Blonna ◽  
Alessandro Cappellari ◽  
...  

Abstract Background Revision surgery after the Latarjet procedure is a rare and challenging surgical problem, and various bony or capsular procedures have been proposed. This systematic review examines clinical and radiographic outcomes of different procedures for treating persistent pain or recurrent instability after a Latarjet procedure. Methods A systematic review of the literature was performed using the Medline, Cochrane, EMBASE, Google Scholar and Ovid databases with the combined keywords “failed”, “failure”, “revision”, “Latarjet”, “shoulder stabilization” and “shoulder instability” to identify articles published in English that deal with failed Latarjet procedures. Results A total of 11 studies (five retrospective and six case series investigations), all published between 2008 and 2020, fulfilled our inclusion criteria. For the study, 253 patients (254 shoulders, 79.8% male) with a mean age of 29.6 years (range: 16–54 years) were reviewed at an average follow-up of 51.5 months (range: 24–208 months). Conclusions Eden–Hybinette and arthroscopic capsuloplasty are the most popular and safe procedures to treat recurrent instability after a failed Latarjet procedure, and yield reasonable clinical outcomes. A bone graft procedure and capsuloplasty were proposed but there was no clear consensus on their efficacy and indication. Level of evidence Level IV Trial registration PROSPERO 2020 CRD42020185090—www.crd.york.ac.uk/prospero/


2021 ◽  
Vol 11 (4) ◽  
pp. 1903
Author(s):  
Adrian Kahn ◽  
Shlomo Matalon ◽  
Rahaf Bassam Salem ◽  
Lazar Kats ◽  
Liat Chaushu ◽  
...  

This study aimed to characterize the demographic and clinical features of underreported surgical ciliated cysts developing after sinus floor augmentation, based on a series of cases from our files and a systematic review of the literature. A series of five cases (four patients) of microscopically confirmed surgical ciliated cysts following sinus floor augmentation procedures from our files are described. A systematic literature search (1991–2020) with strict clinical-, radiological- and microscopic-based exclusion and inclusion criteria was performed to detect additional similar cases. The systematic review revealed only five cases that fulfilled the inclusion criteria. Altogether, surgical ciliated cysts associated with sinus floor augmentation have been rarely reported in the literature, and have not been characterized either demographically or clinically. Graft materials were diverse, implants were placed simultaneously, or up to two years post-augmentation. The associated surgical ciliated cysts developed between 0.5 and 10 years post-augmentation. Although limited in its extent, this study is the first series to characterize possible underreported sequelae of surgical ciliated cysts associated with sinus floor augmentation. It emphasizes the need for long post-operative follow-up and confirmation of lesion by microscopic examination.


Author(s):  
C. Herrera-Vizcaino ◽  
L. Seifert ◽  
M. Berdan ◽  
S. Ghanaati ◽  
M. Klos ◽  
...  

Abstract Background The high-oblique sagittal osteotomy (HOSO) is an alternative to a bilateral sagittal split osteotomy (BSSO). Due to its novelty, there are no long-term studies which have focused on describing the incidence and type of complications encountered in the post-operative follow-up. The aim of this retrospective study is to analyze patients operated on with this surgical technique and the post-operative complications encountered. Patient and methods The electronic medical records of all patients treated with orthognathic surgery at the Department of Oral, Maxillofacial and Facial Plastic Surgery, University Hospital Frankfurt, Goethe University, Frankfurt, Germany, between the years 2009 and 2016 were retrospectively reviewed. Results A total of 116 patients fulfilled the inclusion criteria. The cases operated on with the standard osteosynthesis (X, Y, and straight) showed a complication rate of 36.37% (n = 4/11). The cases operated on with the HOSO-dedicated plates (HOSO-DP) showed, in total, a complication rate of 6.67% (n = 7/105). The most common post-operative complication resulting from both fixation methods was a reduction in mouth opening and TMJ pain for 4.3%. During the first years of performing the surgery (2009–211), a variety of standard plates had material failure causing non-union or pseudarthrosis. No cases of material failure were observed in the cases operated on with the HOSO-DP. The statistical results showed a highly significant dependence of a reduction in OP-time over the years, when the HOSO was performed without additional procedures (R2 > 0.83, P < 0.0015). Conclusion The rate of complications in the HOSO were shown to be comparable to the rate of complications from the BSSO reported in the literature. Moreover, the use of the ramus dedicated plate appears to provide enough stability to the bone segments, making the surgery safer. Clinical relevance The HOSO needs to be considered by surgeons as an alternative to BSSO. Once the use of the HOSO-DP was established, the rate of complications and the operation time reduced considerably.


Sign in / Sign up

Export Citation Format

Share Document