Quantitative Estimation and Method Validation of Acetaminophen by RP-HPLC in Biological Samples

2018 ◽  
Vol 14 (1) ◽  
pp. 17
Author(s):  
Pallavi Choudhary ◽  
A. K. Jaiswal ◽  
Adarsh Kumar
2019 ◽  
Vol 9 (o3) ◽  
Author(s):  
Imad Tarek Hanoon ◽  
Abed Mohammed Daheir AL-Joubory 2 ◽  
Marwa Mohamed Saied 3

A simple , specific, accurate and precise RP-HPLC method was developed for determination of Irbesartan (IRB) in pharmaceutical dosage forms in tablets products and sachet using symmetry (L 1 ) column at 30°C . The signal was detected at 225 nm. A mobile phase dissolve 0.5 g of buffer potassium phosphate in 100 ml distilled water and adjust pH 2.7 , methanol and acetonitrile at ratio (40 :30 :30 ) . and flow rate 1.2ml/min -1 at pH=7.2 a mobile phase The percent recovery was detected 101 % and the linearity of concentration was 10-50 µg.ml -1 and supported this method by using (FT.I.R.) spectrum method for organic spectrophotometer to prove the chemical structure of this drug and some physical properties . we are obtained the result is identical of other literature . The proposed method was applied successfully for determination of the IRB in tablets products.


2011 ◽  
Vol 2011 ◽  
pp. 1-7 ◽  
Author(s):  
Subrata Bhadra ◽  
Sreedam Chandra Das ◽  
Sumon Roy ◽  
Shamsul Arefeen ◽  
Abu Shara Shamsur Rouf

A simple, precise, specific, and accurate reversed phase high performance liquid chromatographic (RP-HPLC) method was developed and validated for determination of vinpocetine in pure and pharmaceutical dosage forms. The different analytical performance parameters such as linearity, accuracy, specificity, precision, and sensitivity (limit of detection and limit of quantitation) were determined according to International Conference on Harmonization ICH Q2 (R1) guidelines. RP-HPLC was conducted on Zorbax C18 (150 mm length × 4.6 mm ID, 5 μm) column. The mobile phase was consisting of buffer (containing 1.54% w/v ammonium acetate solution) and acetonitrile in the ratio (40 : 60, v/v), and the flow rate was maintained at 1.0 mLmin−1. Vinpocetine was monitored using Agilent 1200 series equipped with photo diode array detector (λ = 280 nm). Linearity was observed in concentration range of 160–240 μgmL−1, and correlation coefficient was found excellent (R2 = 0.999). All the system suitability parameters were found within the range. The proposed method is rapid, cost-effective and can be used as a quality-control tool for routine quantitative analysis of vinpocetine in pure and pharmaceutical dosage forms.


2007 ◽  
Vol 45 (5) ◽  
pp. 286-290 ◽  
Author(s):  
A. C. Ayub ◽  
C. D. Vianna-Soares ◽  
L. A. M. Ferreira
Keyword(s):  

2021 ◽  
Vol 09 ◽  
Author(s):  
Priyanka Narula ◽  
Komal Saini ◽  
Megha Saini ◽  
Dinesh Singla ◽  
Anurag Singh Chauhan ◽  
...  

Background: Envisaging the poor solubility (56ng/ml) and permeability of tetrahydrocurcumin (THCC), it was formulated into lipidic nanostructures to enhance its bioavailability upon topical application to promote the healing process for skin inflammatory disorders. Lack of literature on suitable method for determining THCC per se and nanoformulations prompted us to develop a RP-HPLC method to detect the drug in its nanostructures and in pig ear skin post dermatokinetics. Objective: The present investigation aimed to develop a simple, precise and RP-HPLC method for the quantitative estimation of THCC in prepared lipidic nanostructures, its ointment and in skin homogenate obtained post dermatokinetic study. Method: THCC encapsulated nanostructures and ointment were formulated using modified emulsification method and embedded into an ointment base to enhance its spreadability and improve patient compliance. A fast and sensitive reverse phase high performance liquid chromatography method was developed using a Hypersil BDS reverse phase C18 column (4.6 mm × 250 mm, 5 μm) with mobile phase comprising tetrahydrofuran (THF) and 1 mgmL-1 citric acid (4:6), at a flow rate of 1.0 mLmin−1 with a run time of 20 min. Result: THCC nanostructures were successfully prepared using spontaneous microemulsification method. THCC was detected at 282 nm and revealed two peaks which were attributed to the keto-enol tautomerism in the molecule with retention times of 6.23 min and 11.06 min respectively. The assay of THCC in nanostructures and ointment was found to be 98.30% and 99.98% with entrapment efficiency 77.00±2.74 %. The dermatokinetic studies revealed sufficient release of THCC from its ointment up till 24 hr with a concentration of 1382 μgcm-2, for causing a therapeutic effect. Conclusion: The method was found to be reproducible and robust as shown by low coefficient of variation and a constant analyte/IS ratio. It was successfully employed for the estimation of THCC assay in nanostructures and it’s ointment and dermatokinetic analysis in skin.


2013 ◽  
Vol 2013 ◽  
pp. 1-3 ◽  
Author(s):  
R. Kalaichelvi ◽  
E. Jayachandran

A simple, accurate, specific reverse-phase, high-performance liquid chromatography method has been developed for the determination of sorafenib tosylate in its pure form and its tablets. In this method, sorafenib tosylate was eluted by isocratic mode using a Phenomenex Luna C18 column by a mobile phase composition of acetonitrile and water in the ratio of 82.5 : 17.5, v/v. The flow rate was 1.5 mL/min. The eluted drug was monitored at 265 nm and the method was found to be linear from 5 to 80 μg/mL. The method was validated by linearity, precision, accuracy, LOD, and LOQ. The accuracy report denotes that there is not any interference of additives used in the formulation.


2019 ◽  
Vol 57 (7) ◽  
pp. 636-643 ◽  
Author(s):  
Aya A Youssef ◽  
N Magdy ◽  
Lobna A Hussein ◽  
A M El-Kosasy

Abstract Egypt has the highest prevalence of hepatitis C virus (HCV) in the world thus it launched a national program for eliminating HCV aiming to treat 300,000 HCV patients per year. Three anti-HCV co-administered drugs; ribavirin (RBV), sofosbuvir (SF) daclatasvir (DAC) were simultaneously determined in human plasma by a validated, simple and sensitive RP-HPLC method using propyl paraben as an internal standard. Liquid–liquid extraction using ethyl acetate was used for samples extraction. Chromatographic separation was achieved on Scharlau® C18 column (250 × 4.6 mm2, 5 μm). Gradient elution was employed with a mobile phase mixture of water and acetonitrile at a flow rate 1 mL/min. UV detection using photodiode array detector was carried out at 207, 260 and 312 nm for RBV, SF and DAC, respectively. Method validation was performed according to the FDA guidelines for bioanalytical method validation. The calibration curves were linear over the ranges (0.5–80, 0.1–40 and 0.5–80 μg/mL) with average recoveries (100.64–108.28%, 98.48–105.91% and 97.68–101.38%) for RBV, SF and DAC, respectively. The intra-day and inter-day precision and accuracy results were within the acceptable limits. Stability assays revealed that the three studied analytes were stable during sample storage, preparation and injection. The method can be successfully applied in routine analysis of plasma of HCV patients treated with this combination therapy which aids in therapeutic drug monitoring and patients’ follow-up especially in Egypt and other developing countries fighting HCV.


2017 ◽  
Vol 9 (6) ◽  
pp. 34
Author(s):  
Madhavi K. ◽  
Navamani M. ◽  
Prasanthi C.

Objective: To develop a simple, rapid, economic, accurate and precise reverse phase-high performance liquid chromatographic (RP-HPLC) method for the determination of hydrochlorothiazide and candesartan in the pharmaceutical dosage form and to validate as per international conference on harmonization (ICH) guidelines.Methods: The chromatographic separation was performed on Silanol BDS C18 column (250 x 4.6 mm, 5 μm), a mobile phase consisting of water (pH adjusted to 2.8 with orthophosphoric acid): acetonitrile (30:70 % v/v), with a flow rate 1 ml/min and the detection wavelength of 210 nm using photodiode array (PDA) detector.Results: The developed method resulted in elution of hydrochlorothiazide at 2.28 min and candesartan at 4.28 min. The calibration curves were linear (r2=0.999) in the concentration range of 6.25-18.75 μg/ml and 8-24 μg/ml for hydrochlorothiazide and candesartan respectively. The percentage recoveries were found to be 99.78-100.39 for hydrochlorothiazide and 99.87-100.64 for candesartan. The limit of detection (LOD) was found to be 0.410 μg/ml and 0.699 μg/ml for hydrochlorothiazide and candesartan respectively. The limit of quantitation (LOQ) was found to be 1.367 μg/ml and 2.330 μg/ml for hydrochlorothiazide and candesartan respectively.Conclusion: A simple, economic, accurate, precise, linear and rapid RP-HPLC method was developed for simultaneous quantitative estimation of hydrochlorothiazide and candesartan in bulk and pharmaceutical formulation and the method was validated as per ICH guidelines. Hence, the method holds good for the routine analysis of hydrochlorothiazide and candesartan in various pharmaceutical industries as well as in academics.


Sign in / Sign up

Export Citation Format

Share Document