scholarly journals Effect of Silver Nanoparticles on Some Physical& Biological Properties of Fluid Denture Base Material

2020 ◽  
Vol 04 (1) ◽  
pp. 27-40
Author(s):  
Jaymin Taher ◽  
Salem Salem

Poly methyl methacrylate (PMMA) is one of the most widely used materials in modern prosthodontics. It is widely known due to its simplicity in use and acceptable aesthetic. A new concept of polymerization fluid resin technique was instead of heat and gypsum material. Forty specimens were prepared from two brands of fluid acrylic resin. The samples were divided into two groups, the first one was the control while the other group was incorporated with silver nanoparticles(modified). The tests performed were impact strength, transverse strength, color stability and candida retention ability on the samples. 10 samples for each test were used. The results showed that modified group had significantly higher impact strength than the control group. There was non-significant difference between group of modified fluid acrylic and control group. Regarding color stability, there were highly significant color change after 10 days of immersion in the tea solution for the modified group the results of the biological test showed that the candida retention of the control group was significantly higher than modified group. Within the limitation of this study it can be concluded that addition of silver nanoparticles has resulted in significant difference between control and modified group for impact strength test. While non-significant difference was seen for transverse strength test. In regard to color stability, showed enhancement in color stability for both before and after placement in tea solution. Addition of silver nanoparticles also caused reduction in candida albicans retention in the added samples.

2019 ◽  
Vol 10 (2) ◽  
pp. 1464-1469
Author(s):  
Adnan R. Al Assal ◽  
Abdalbaset A Fatalla ◽  
Mohammed Moudhaffar ◽  
Ghasak H Jani

The general upgrading of polymer denture base material and research continuously looking for ideal restorative dental material with better properties, adequate esthetic properties, less expensive and easier to handle material to develop photo polymerization dental materials. This study was conducted to evaluate the effect of addition polyamide on mechanical microparticle properties light cure denture base material. One hindered sixty specimens from light-cured acrylic resin (Aurora). The divided mainly into four groups according to test used (Transverse strength test, impact strength test, hardness test and tensile strength test) with 40 specimens for each group. The results show an increase in Transverse strength, impact strength, hardness and tensile strength in all experimental group when compared to control group the highest mean values for all tests included in the study appeared in group B 1% polyamide. The addition of polyamide microparticle improves transverse, tensile, impact strength and hardness properties of denture base material.


2021 ◽  
Vol 74 (9) ◽  
pp. 2293-2296
Author(s):  
Rafah Habib Abdul Amir

The aim: This study evaluates the effect of adding silanized halloysite nanotubes to the polymethylmethacrylate (PMMA) resin on its hardness, impact strength, transverse strength. Materials and methods: Three groups of acrylic resin were prepared, one group without HNTs, was used as a control group (A). The other two groups contained 0.3% (B), 0.6% wt of silanized halloysite nanotubes (C). For each one, hardness, impact strength and transverse strength were measured. One-way ANOVA and Tukey’s test were used for comparison. Results: Regarding to the impact test, there was no significant difference between 0.3% concentration and the pure (control) group while 0.6% concentration had significant decrease compared to the pure group and so between the 0.3% group 0.6% group. For the hardness test, the 0.3% group had no significant difference with the pure group and a significant difference between group 0.6% group and the pure group while there was a no significant decrease between the 0.3% and 0.6% group with the higher hardness mean in the 0.3% compared to 0.6% group. For the transverse strength, both 0.3% wt concentration and 0.6% concentration showed significant difference compared to the pure group and also between each other with the lowest impact strength in 0.6% group followed by 0.3% group with the highest transverse strength in the pure group. Conclusions: The silanation of halloysite nanotubes reduces the mechanical properties of the heat-cured acrylic denture base material. The more concentration of silanazed halloysite nanotubes is added, the more weakening occurs in the acrylic material relating to the hardness, transverse strength and impact strength.


2018 ◽  
Vol 5 (4) ◽  
pp. 76
Author(s):  
Mone Laiz Bortoli ◽  
Cristina Von Appen ◽  
Camila Longoni ◽  
Carmen Beatriz Borges Fortes ◽  
Jefferson Tomio Sanada

Aim: This work aimed to evaluate the color stability of an acrylic resin chemically activated (ARCA) using different handling techniques, and a bisacrylic resin when exposed to different pigmentation solutions.Material and Methods: Silicon matrixes were confectioned (10x10x3mm) to be used as specimens. The groups were designed as follows: Group Pot, Group Brush, Group Manufacturer and Group Bisacrylic (n=18). Each group was exposed to three different pigmentation solutions: distilled water, coke and chlorhexidine digluconate 0.12%. Three readings were performed for each specimen using a spectrophotometer, and the evaluations were carried out in three different time. After the color reading, three averages and the standard deviation of variation were performed after 24 hours (T1), 7 days (T2) and 14 days (T3). Data were submitted to the ANOVA and 2 criteria and Tukey (P<0.05) in the statistical software SSPS 18 for Macintosh (SPSS Inc., Chicago, USA).Results: When compared the solutions in each group of material, there was no statistically significant difference, except for T3, where the group Dencor Brush and Bisacrylic demonstrated higher color variation in all the solutions, even in the control group, and the values in Chlorhexidine higher than the other, showing greater instability after 14 days.Conclusions: With the results, bisacrylic resin used as provisory prosthesis material presents greater color instability than the ARCA, when submitted to different solutions. Bisacrylic resin and Dencor Brush present significantly visible color changes in chlorhexidine solution after 14 days. All the materials in coke solution present homogeneity in the color change after 7 days exposition to the solution, with no visible color change.


2020 ◽  
Vol 23 (4) ◽  
pp. 9p
Author(s):  
Alperen Degirmenci ◽  
Emine Kara ◽  
Beyza Unalan Degirmenci ◽  
Mutlu Ozcan

Objective: Vital bleaching is popular treatment option for discolored teeth. But at post-treatment stage, loss of adhesion is highly reported. Literature focused on antioxidant application for the answer of this issue. The aim of this study is comparing effects of six different antioxidants on color stability of bleached teeth. Material and Methods: This study includes total of 84 extracted intact non-carious lower incisors. 35% hydrogen peroxide was applied on the labial surfaces of specimens in accordance with manufacturer's instructions. The bleached teeth were divided into 7 groups. No antioxidants were applied to the control group. For the experimental groups, the following antioxidants were applied for 10 minutes each: 5% proanthocyanidin, 5% sodium ascorbate, 5% lycopene, %5 green tea, %5 white tea and %5 ?-tocopherol. CIE L*, a* and b* values of the teeth were measured by a spectrophotometer. The data were analyzed using IBM SPSS version 23. Results: The differences between the groups were determined with one-way ANOVA. The one-way ANOVA test revealed a statistically significant difference between the groups (p<0.005). Highest color change was observed in lycopene group and the lowest was belongs to green tea group. Conclusions: Proanthocyanidin, white tea and green tea could be good post-bleaching antioxidant alternatives based on their herbal nature.


2017 ◽  
Vol 8 (1-2) ◽  
pp. 34-41
Author(s):  
Abdullah Saad Al-Abdullah ◽  
Roula S. Al-Bounni ◽  
Mohammad Al-Omari

Objective: To evaluate the color stability of Tetric® N-Ceram Bulk Fill composite restorative material after immersion in three different (energy drink, protein supplement solution, and combination of energy drink and protein supplement solution) drinks. Materials and Methods: Composite resin disks, 2 mm in depth and 5 mm in diameter, were prepared from the Tetric® N-Ceram Bulk Fill composite restorative material. Specimens were tested after immersion and aging in energy drink (Red Bull) alone, protein supplement solution alone, and in combination with energy drink and protein supplement. Deionized water was used as a control group. Specimens were stored at room temperature of ±23°C for a period of one week in each drink. Color was assessed in the CIELAB using Color Eye 7000A Spectrophotometer. Color differences in different group specimens were measured. Mean values were statistically analyzed using one-way analysis of variance (ANOVA). Further Tukey’s multiple comparison tests were applied to know the differences between the group of specimens. A p value of p < 0.05 was set as significance level. Results: N-Ceram Bulk Fill composite showed Δ L, Δ a, Δ b, and Δ E mean and standard deviation values when immersed in deionized water (–2.6 ± 3.24, 0.16 ± 0.19, 0.32 ± 1.26, and 3.51 ± 2.47), energy drink (–4.19 ± 4.24, 0.21 ± 0.21, 1.57 ± 1.32, and 5.40 ± 3.11), protein supplement (62.71 ± 12.48, –2.63 ± 0.7, 7.7 ± 5.67, and 63.45 ± 12.56), combined energy drink and protein supplement (68.52 ± 13.43, –4.06 ± 1.73, 10.94 ± 5.31, and 69.71 ± 13.42), respectively. All the color coordinates (Δ L, Δ a, and Δ b) showed statistically significant difference, p < 0.001. The color change of N-Ceram Bulk Fill composite specimens Δ E occurred by immersion in energy drink, protein supplement solution, and combined solution of energy drink and protein supplement after seven days was found to be statistically significant p < 0.001. Conclusion: The study’s finding suggests that the energy drink (Red Bull), protein supplement (ISOPURE), and combined immersion in energy drink and protein supplements caused perceptible and clinically unacceptable color change in the Tetric® N-Ceram Bulk Fill composite material. This color change was remarkably high with a combined immersion in energy drink and protein supplement solution.


2018 ◽  
Vol 12 (1) ◽  
pp. 202-212 ◽  
Author(s):  
Hawraa Khalid Aziz

Background: The criteria of conventional curing of polymethyl methacrylate do not match the standard properties of the denture base materials. Objectives: This research was conducted to investigate the addition of TiO2 nano practical on impact strength, thermal conductivity and color stability of acrylic resin cured by microwave in comparison to the conventional cured of heat-polymerized acrylic resin. Materials and Methods: 120 specimens made of high impact acrylic resin were divided into two main groups according to the type of curing (water bath, microwave), then each group was subdivided into two groups according to the addition of 3% TiO2 nano-fillers and control group (without the addition of TiO2 0%). Each group was subdivided according to the type of test into 3 groups with 10 specimens for each group. Data were statistically analyzed using Student t-test to detect the significant differences between tested and control groups at significance level (P<0.05). Results: According to curing type methods, the results showed that there was a significant decrease in impact strength of microwaved cured resin, but there was no significant difference in the thermal conductivity and color stability of resin. In addition, by using nanofiller, there was a significant increase in the impact strength and color stability with the addition of 3% TiO2 nanofillers, but no significant difference was found in the thermal conductivity of the acrylic resin. Conclusion: The microwave curing of acrylic resin had no change in the color stability and thermal conductivity in comparison to the water bath, but the impact strength was decreased. The addition of 3% TiO2 improved the impact and the color stability, but the thermal conductivity did not change.


2021 ◽  
Vol 5 (4) ◽  
pp. 106
Author(s):  
Lissethe Peñate ◽  
Montse Mercade ◽  
María Arregui ◽  
Miguel Roig ◽  
Juan Basilio ◽  
...  

The color stability of interim computer-aided design and computer-assisted manufacturing (CAD/CAM) materials has not been exhaustively investigated. The aim of this study was to compare the translucency (TP) and contrast ratio (CR) of CAD/CAM blocks and conventional interim materials, as well as the effects of varnish application and tooth-brushing on color stability after immersion in different staining solutions. Four hundred and eighty specimens were fabricated with four different interim materials (n = 120) and were divided into three experimental, and one control group (n = 30). The color measurements were taken at the initial time (T0), 24 h (T1), 7 days (T2), and 30 days (T3) after immersion in different solutions. CIEDE2000 (ΔE00) values were analyzed with ANOVA and Fischer’s LSD test with a 95% confidence interval. The relationship between TP and CR was analyzed with a Pearson correlation. All interim materials showed a significant difference (p < 0.05) in color change after 30 days. Results showed that polyethyl methacrylate resins (PEMA) had the highest stability over time. The TP and CR were statistically significant (p < 0.05). It was observed that brushing improved the color stability but the ΔE00 were the highest when the varnish alone or varnish and brushing were used, except in the bis-acryl group, in which varnish and brushing decreased the color stainability.


Author(s):  
Işıl Sarıkaya ◽  
Hande Dilli

Purpose: The aim of this study was to compare the color stability of two different hybrid ceramic materials. Materials & Methods: Using the precision cutting device (Micracut, Metcon, Turkey), 36 specimens (12 x 15 x 1 mm) were obtained from Vita Enamic (Vita Zahnfabrik, Germany) and Lava Ultimate (3M ESPE, St.Paul, USA) CAD / CAM blocks. After finishing procedures were completed, all specimens were stored in distilled water for 24 h. Then, the specimens were dried and the initial color measurements were made. L, a, b values were determined using a spectrophotometer (Vita Easy Shade, Vita Zahnfabrik, Germany). The specimens were then divided into 3 test groups and stored in coffee (Nescafe Classic, Turkey) (G2, G5), energy drink (Red Bull, Austria) (G3, G6), and in the distilled water as the control group (G1, G4), for 48 h. After 48 h, the specimens were washed with distilled water and dried. Second color measurements were made. ∆E00 values were calculated using the CIEDE 2000 color-difference formula. Results: Data were analyzed by two-way ANOVA. Multiple comparisons were made with Bonferroni’s test. There was a statistically significant difference between 2 ceramics (p=0.035). Generally, Lava Ultimate showed more color change than Vita Enamic. Among the beverages, coffee was significantly different for both ceramics than control and energy drink (p<0.05). Conclusion: Lava Ultimate, showed more color change than Vita Enamic. Coffee has also been determined as the most colorant drink for both hybrid ceramics.


2015 ◽  
Vol 44 (5) ◽  
pp. 262-267 ◽  
Author(s):  
José Vitor Quinelli Mazaro ◽  
Luiz Miguel Minani ◽  
Adriana Cristina Zavanelli ◽  
Caroline Cantieri de Mello ◽  
Cleidiel Aparecido Araújo Lemos

AbstractIntroductionTemporary restorative materials are widely used, however, little is know about their color stability.Objectiveto evaluate the color stability of the following temporary restorative materials: acrylic and bis-acrylic resins after immersion in pigmenting solutions for different periods of storage.Material and methodFour materials were tested (Dêncor/Clássico, Protemp 4/3M ESPE; Structur 2 SC/Voco; Luxatemp AM Plus/DMG) and 30 test specimens (15 mm in diameter and 2 mm thick) per material were fabricated. They were divided according to the storage medium (artificial saliva, saliva + cola type soda, and saliva + coffee) and storage time intervals (2, 5, 7 and 15 days). Color measurements were made before and after immersions, with use of a spectrophotometer, by means of the CIE L*a*b* system. The data were analyzed by the analysis of variance and the Tukey Test, at a level of significance of 5%.ResultAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). When bis-acrylic resins were compared no significant difference was observed between the resins Structur and Luxatemp (p=0.767). As regards solutions tested, coffee showed the highest color change values (p<0.001), and the longer the storage time interval, the greater was the color change in all the temporary restorative materials analyzed (p<0.001).ConclusionAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). Coffee caused the greatest color change, and immersion time was determinant in color stability of the temporary materials analyzed.


2020 ◽  
Vol 14 (01) ◽  
pp. 085-091
Author(s):  
Sedighe Sadat Hashemikamangar ◽  
Farnoosh Hoseinpour ◽  
Nazanin Kiomarsi ◽  
Mehrzad Gholampour Dehaki ◽  
Mohammad Javad Kharazifard

Abstract Objectives This study aimed to assess the effect of an optical whitening toothpaste on color stability of microhybrid, nanofilled, and microfilled composite resins and resin-modified glass ionomer (RMGI) cement in comparison of two other toothpastes. Materials and Methods In this experimental study, disc-shaped composite samples were fabricated. The samples were then polished using silicon carbide papers. Twenty-seven samples of each material were fabricated and subjected to colorimetry using a spectrophotometer. Each group of material was then divided into three subgroups for the application of conventional whitening and whitening containing blue covarine toothpastes. One operator brushed the samples with an electric soft toothbrush with circular motion twice a day, each time for 30 seconds. Colorimetry was performed at 0, 1, 7, 30, and 90 days. Statistical Analysis Two-way analysis of variance (ANOVA), one-way ANOVA, and Tukey’s honestly significant difference (HSD) test were used for statistical analysis. Results The interaction effect of type of restorative material and time on ∆E was not significant at baseline or 1 day (p > 0.05). The effect of type of toothpaste on ∆E was not significant at baseline or 1 day (p = 0.78) but the effect of type of material was significant (p < 0.05). The toothpastes had significantly different effects on ∆E of Z250 at all time points (p < 0.05) except for ∆E0–30 (p = 0.106). The toothpastes had significantly different effects on ∆E of Z350 and Gradia at all time points (p < 0.05). The same was true for RMGI except for ∆E0–7 (p = 0.43) and ∆E0–90 (p = 0.52). The majority of color changes caused by toothpastes were not clinically perceivable (∆E < 3.3), except for ∆E0–90 by the whitening toothpaste (∆E = 9), ∆E0–90 by the conventional toothpaste for Z350 (∆E = 3.9), and ∆E0–1 by the whitening toothpaste for RMGI (∆E = 3.7). Conclusion The color change of all composite samples was not clinically perceivable (<3.3) at all time points, which shows that the tested toothpastes do not cause a significant change in color of composite materials.


Sign in / Sign up

Export Citation Format

Share Document