The efficiency of applying air conditioning units for comfort and energetics for a certain period, as well as any power plant, is determined by the effect obtained, primarily in the form of reducing fuel consumption over the year or increasing the production of electrical (mechanical) energy in the case of air conditioning at the heat engine inlet and by annual cold production as an indicator of the efficiency of using the cooling capacity of comfort air-conditioning plants. Since in both cases the effect depends on the duration and depth of cooling, it is quite justified to estimate it in the first approximation by the thermal hourly potential, which is the result of summation hour by hour of air temperature drops multiplied by duration of operation at a lowered temperature and, thus, takes into account current climatic conditions. Obviously, the realization of the cooling potential (air conditioning) of the ambient air depends on the installed (design) cooling capacity of the air conditioning units, which, in turn, must take into account the fluctuations in thermal loads in accordance with the current variable thermal and humidity parameters of the ambient air. Based on the different rates of the increment of the annual thermal hourly cooling potential with an increase in the installed cooling capacity of the air conditioning unit due to a change in the heat load in accordance with current climatic conditions during the year, it is necessary to choose such a design thermal load on the air conditioning unit (its installed cooling capacity) that ensures maximum or close to it the annual thermo-hour cooling potential at a relatively high rate of its increment, respectively, and the effect of cooling in the form of a decrease in fuel consumption per year in the case of air conditioning at the inlet of heat engine and annual cold production of comfort air conditioning units. It is shown that under the same climatic conditions during the year and the depth of ambient air cooling, the rational values of the design cooling capacity of air conditioning units for comfort and energy purposes are the same.

2019 ◽  
pp. 24-29
Author(s):  
Євген Іванович Трушляков ◽  
Андрій Миколайович Радченко ◽  
Сергій Георгійович Фордуй ◽  
Анатолій Анатолійович Зубарєв ◽  
Сергій Анатолійович Кантор ◽  
...  

Since the supply air conditioning systems operation effect depends on the cooling duration and depth, it is quite justified to estimate it by the value of the specific annual cold production, which is the product of the necessary cooling capacity for cooling the air to the target temperature multiplied by duration of operation at a given cooling capacity and, thus, considers current climatic conditions. Obviously, the realization of the cooling potential (air conditioning) of the ambient air depends on the installed (design) cooling capacity of the air conditioning units, which, in turn, must considering fluctuations in thermal loads by the current variable thermal and humidity parameters of the ambient air. With an increase in the temperature of the ambient air, fuel consumption for the production of a unit capacity (mechanical/electrical energy) increases, and, accordingly, the more harmful substances are removed to the atmosphere with exhaust gases. To reduce the negative impact of unproductive fuel consumption during the operation of air conditioning systems at elevated ambient temperatures, resort to various methods for determining the installed cooling capacity of the installation, to reduce it. In the work, the ecological efficiency of air cooling is studied considering the climatic operating conditions for the Kyiv city that are variable during the year. The annual reduction in emissions of carbon dioxide CO2 and nitric oxide NOX was chosen as indicators for assessing the environmental effect of air cooling. It has been shown that when choosing the installed cooling capacity, by the method of ensuring the maximum growth rate of the annual cold production considering the increase in the installed cooling capacity of the chiller, there is a greater reduction in specific fuel consumption compared to the method of choosing the maximum annual cold production, respectively, and harmful emissions. When comparing the methods for choosing the design cooling capacity, air cooling to 15 °C provides a reduction in carbon dioxide CO2 emissions of more than 34 t for 2017 for the climatic conditions of Kiev, in favor of the method of ensuring the maximum growth rate of annual cold production, and nitric oxide NOX – about 5,8 t.


2019 ◽  
pp. 15-19
Author(s):  
Євген Іванович Трушляков ◽  
Андрій Миколайович Радченко ◽  
Сергій Анатолійович Кантор ◽  
Веніамін Сергійович Ткаченко ◽  
Сергій Георгійович Фордуй ◽  
...  

The cold output for the heat-moisture treatment of ambient air in air conditioning systems depends on its parameters (temperature and relative humidity), which vary significantly during operation. To determine the installed (design) cooling capacity of air conditioning system chillers, it is proposed to use a reduction in fuel consumption of a power plant or cooling capacity generation following its current conditioning spending over a certain period, since both of these indicators characterize the efficiency of using the installed cooling capacities of the air conditioning system. To extend the results of the investigation to a wide range of air conditioning units, two methods were used to determine the design cooling capacity (refrigerating capacity): by the maximum annual value and by the maximum growth rate of the efficiency indicator. The first method allows choosing the design cooling capacity, which provides a maximum annual reduction in the specific fuel consumption due to air cooling or maximum cooling capacity generation, which is necessary for air cooling following current climatic conditions. The second method allows determining the minimum design (installed) cooling capacity of chillers, which provides the maximum rate of reduction in fuel consumption by the power plant and the increment in the annual cooling capacity generation following the installed cooling capacity of chillers. The efficiency of air conditioning systems was analyzed for different climatic conditions: a temperate climate using the example of Voznesensk city (Ukraine) and the subtropical climate of Nanjing city (China). It is shown that the design cooling capacity values calculated by both indicators of its use efficiency are the same for the same climatic conditions. Wherein, if to determine the design cooling capacity by both methods - by the maximum annual value and the maximum rate of growth of the indicator, its values turned out to be quite close for tropical climatic conditions and somewhat different for a temperate climate.


2019 ◽  
pp. 56-60
Author(s):  
Андрій Миколайович Радченко ◽  
Ян Зонмін ◽  
Микола Іванович Радченко ◽  
Сергій Анатолійович Кантор ◽  
Богдан Сергійович Портной ◽  
...  

Significant fluctuations of the current temperature and relative humidity of the ambient air lead to significant changes in the thermal load on the cooling system at the inlet of gas turbine units (GTU), which acutely raises the problem of choosing their installed (design) thermal load. Calculations of ambient air cooling processes were carried out for different climatic conditions, for example, southern Ukraine (Mykolaiv) and Central China (Beijing). It is  analyzed two methods of determination of the installed (design) cooling capacity of the ambient air cooling system at the GTU inlet according to the maximum current reduction of fuel consumption and according to the maximum rate (increase) of annual reduction of fuel consumption following to increasing of the installed cooling capacity, calculated by summarizing the current values of fuel consumption reduction. It is shown that the values of the installed cooling capacity of the air cooling system at the GTU inlet, determined by both methods, are close enough but differ significantly for different climatic conditions. The advantage of the method of calculating the installed cooling capacity of the air cooling system at the GTU inlet according to the maximum rate of annual reduction in fuel consumption is the possibility of a more precise definition of it due to the absence of significant fluctuations in the annual reduction in fuel consumption, calculated by summarizing the current values of fuel consumption reduction. Since the maximum reduction in fuel consumption per year is achieved with some decrease in the rate of its increment at high values of the design cooling capacity, required in the hottest hours in the summer and excessive in somewhat cool periods (at night and in the morning even in the summer), the installed cooling capacity, determined according to the maximum rate of the reduction of fuel consumption, will be insufficient in times of increased thermal loads above their design value. In such cases, the elimination of the deficit in cooling capacity is possible by using an excess of cold accumulated during reduced thermal loads


2018 ◽  
Vol 70 ◽  
pp. 03012 ◽  
Author(s):  
Roman Radchenko ◽  
Andrii Radchenko ◽  
Serhiy Serbin ◽  
Serhiy Kantor ◽  
Bohdan Portnoi

Two-stage Gas turbine unite (GTU) inlet air cooling by absorption lithium-bromide chiller (ACh) to the temperature 15 °C and by refrigerant ejector chiller (ECh) to 10 °C through utilizing the turbine exhaust gas heat for changeable ambient air temperatures and corresponding heat loads on the air coolers for the south Ukraine climatic conditions is analysed. An excessive refrigeration capacity of combined absorption-ejector chiller (AECh) exceeding the current heat loads and generated at decreased heat loads on the air coolers at the inlet of GTU can be used for covering increased heat loads to reduce the refrigeration capacity of AECh. The GTU inlet air cooling system with an ambient air precooling booster stage and a base two-stage cooling air to the temperature 10 °C by AECh is proposed. The AECh excessive cooling capacity generated during decreased heat loads on the GTU inlet air coolers is conserved in the thermal accumulator and used for GTU inlet air precooling in a booster stage of air cooler during increased heat loads. There is AECh cooling capacity reduction by 50% due to the use of a booster stage for precooling GTU inlet ambient air at the expense of an excessive cooling capacity accumulated in the thermal storage.


2019 ◽  
pp. 49-53
Author(s):  
Євген Іванович Трушляков ◽  
Микола Іванович Радченко ◽  
Андрій Миколайович Радченко ◽  
Сергій Георгійович Фордуй ◽  
Сергій Анатолійович Кантор ◽  
...  

Maintaining the operation of refrigeration compressors in nominal or close modes by selecting a rational design thermal load and distributing it in response to the behavior of the current thermal load according to the current climatic conditions is one of the promising reserves for improving the energy efficiency of air conditioning systems, which implementation ensures maximum or close to it in the annual cooling production according to air conditioning duties. In general case, the total range of current thermal loads of any air-conditioning system includes a range of unstable loads caused by precooling of ambient air with significant fluctuations in the cooling capacity according to current climatic conditions, and a range of relatively stable cooling capacity expended for further lowering the air temperature from a certain threshold temperature to the final outlet temperature. If a range of stable thermal load can be provided within operating a conventional compressor in a mode close to nominal, then precooling the ambient air with significant fluctuations in thermal load requires adjusting the cooling capacity by using a variable speed compressor or using the excess of heat accumulated at reduced load. Such a stage principle of cooling ensures the operation of refrigerating machines matching the behavior of current thermal loads of any air-conditioning system, whether the central air conditioning system with ambient air procession in the central air conditioner or its combination with the local indoors recirculation air conditioning systems in the air-conditioning system. in essence, as combinations of subsystems – precooling of ambient air with the regulation of cooling capacity and subsequent cooling air to the mouth of the set point temperature under relatively stable thermal load.


2019 ◽  
pp. 4-8
Author(s):  
Андрій Миколайович Радченко ◽  
Микола Іванович Радченко ◽  
Ян Зонмін ◽  
Сергій Анатолійович Кантор ◽  
Богдан Сергійович Портной

The operation of gas turbine unites significantly depends on the ambient air temperature at the inlet, and the higher it is, the greater the specific fuel consumption is spent for the production of a unit capacity (mechanical/electrical energy), and, accordingly, the more harmful substances are removed to the atmosphere with exhaust gases. To reduce the negative impact of unproductive fuel consumption during the operation of gas turbine units at elevated ambient temperatures, the inlet air cooling is applied. The paper studies the ecological efficiency of gas turbine unite inlet air cooling, taking into account the variable climatic operation conditions for regions with different climatic conditions over a period of five years (2014-2018): temperate climate of Ukraine (on the example of cities Sumy and Ternopol) and the subtropical climate of the PRC (cities Beijing and Nanjing). The annual reduction in emissions of carbon dioxide CO2 and nitric oxide NOX was chosen as indicators for assessing the environmental effect of air cooling. It has been shown that deeper cooling gas turbine unite inlet air to 7...10 °C provides almost a half to two times greater reduction in specific fuel consumption, respectively, and harmful emissions compared with traditional cooling to 15 °C by the most widespread absorption lithium-bromide chillers, and for the temperate climate of Ukraine the relative effect is much greater than for the subtropical climatic conditions of the PRC. Reducing carbon dioxide CO2 over five years for the PRC climate when cooling air to 10 °C is approximately more than 500 t, and for Ukraine – more than 240 t, and NOX nitric oxide – about 3.5 t for China and 1.6 t for Ukraine, while with traditional cooling to 15 °C: more than 300 t for China, and for Ukraine about 120 t, and nitric oxide NOX – about 2 t for China and 0.7 t for Ukraine. Based on the results of a rough assessment of the environmental effect of cooling the ambient air at the inlet of gas turbine units, in the temperate climate of Ukraine, deep cooling of the air is especially advisable, which provides almost twice the effect compared with traditional cooling to 15 °C.


Energies ◽  
2020 ◽  
Vol 13 (23) ◽  
pp. 6201
Author(s):  
Andrii Radchenko ◽  
Eugeniy Trushliakov ◽  
Krzysztof Kosowski ◽  
Dariusz Mikielewicz ◽  
Mykola Radchenko

The efficiency of cooling ambient air at the inlet of gas turbines in temperate climatic conditions was analyzed and reserves for its enhancing through deep cooling were revealed. A method of logical analysis of the actual operation efficiency of turbine intake air cooling systems in real varying environment, supplemented by the simplest numerical simulation was used to synthesize new solutions. As a result, a novel trend in engine intake air cooling to 7 or 10 °C in temperate climatic conditions by two-stage cooling in chillers of combined type, providing an annual fuel saving of practically 50%, surpasses its value gained due to traditional air cooling to about 15 °C in absorption lithium-bromide chiller of a simple cycle, and is proposed. On analyzing the actual efficiency of turbine intake air cooling system, the current changes in thermal loads on the system in response to varying ambient air parameters were taken into account and annual fuel reduction was considered to be a primary criterion, as an example. The improved methodology of the engine intake air cooling system designing based on the annual effect due to cooling was developed. It involves determining the optimal value of cooling capacity, providing the minimum system sizes at maximum rate of annual effect increment, and its rational value, providing a close to maximum annual effect without system oversizing at the second maximum rate of annual effect increment within the range beyond the first maximum rate. The rational value of design cooling capacity provides practically the maximum annual fuel saving but with the sizes of cooling systems reduced by 15 to 20% due to the correspondingly reduced design cooling capacity of the systems as compared with their values defined by traditional designing focused to cover current peaked short-term thermal loads. The optimal value of cooling capacity providing the minimum sizes of cooling system is very reasonable for applying the energy saving technologies, for instance, based on the thermal storage with accumulating excessive (not consumed) cooling capacities at lowered current thermal loads to cover the peak loads. The application of developed methodology enables revealing the thermal potential for enhancing the efficiency of any combustion engine (gas turbines and engines, internal combustion engines, etc.).


2018 ◽  
pp. 29-33
Author(s):  
Евгений Иванович Трушляков ◽  
Николай Иванович Радченко ◽  
Вениамин Сергеевич Ткаченко

It is determined that the operation of ambient air conditioning systems (AACS) has significant fluctuations in the heat load in accordance with current climatic conditions. This makes very problematic the application of refrigeration compressors with frequency converters, which are very effective for controlling the refrigeration capacity in closed air conditioning systems, in which the temperature control range and, accordingly, fluctuations in thermal load are insignificant in comparison with the ambient air cooling. For the purpose of analyzing the efficiency of controlling the refrigeration capacity of the AACS by changing the electric motor speed of the piston compressor in current climatic conditions, the entire range of changing current thermal loads is divided into two parts according to controlling the refrigeration capacity by appling a frequency converter: the part of effective cooling capacity adjustment without energy losses (without reducing the coefficient of performance) from nominal to its threshold value and the part of reduced refrigeration capacity without its controlling by a frequency converter. It is revealed that for the warmest summer month, the proportion of refrigeration capacity spent for cooling ambient air to the temperature of 10 °C with 50 % frequency controlling the refrigeration capacity is about 10 % of the total amount of that could be produced at nominal refrigeration capacity. At higher temperatures of cooled air is even less. This shows the low efficiency of controlling the refrigeration capacity of the AACS by changing the speed of rotation of the piston compressor electric motor and the need to use other methods of controlling the refrigeration capacity. The proposed approach to analyzing the efficiency of controlling the refrigeration capacity of AACS in current climatic conditions allows not only to estimate the efficiency of refrigeration capacity controlling method but also to reveal the reserves for increasing the efficiency of applying the available refrigeration capacity


2019 ◽  
pp. 71-75
Author(s):  
Євген Іванович Трушляков ◽  
Андрій Миколайович Радченко ◽  
Микола Іванович Радченко ◽  
Сергій Георгійович Фордуй ◽  
Сергій Анатолійович Кантор ◽  
...  

One of the most attractive reserves for improving the energy efficiency of air conditioning systems is to ensure the operation of refrigeration compressors in nominal or close to nominal modes by selecting a rational design heat load and distributing it within its design value according to the behavior of the current heat load under variable current climatic conditions to provide the maximum or close to maximum annual cooling capacity generation according to cooling duties of air conditioning. In the general case, the overall range of current thermal loads of any air conditioning system includes a range of unstable loads associated with the precooling of ambient air with significant fluctuations in cooling capacity according with current climatic conditions, and a relatively stable range of cooling capacity consumed to further reduce air temperature from a certain threshold temperature to the final outlet temperature. It is quite obvious that a stable range of heat load can be ensured within operating a conventional compressor in a mode close to the nominal mode while precooling the ambient air with significant fluctuations in heat load requires regulation of the cooling capacity through the use of a variable speed compressor. Thus, in response of the behavior of the change in current heat loads, any air conditioning system, whether the central air-conditioning system with its heat procession in a central air conditioner, or a combination thereof with a local recirculation system of indoor air, essentially consists of two subsystems: pre-cooling the ambient air and then cooling it to the set point temperature. The proposed method of distribution of design heat load depending on the behavior of the current heat load is useful for the rational design of central air conditioning systems and their combined versions with the local air conditioning system.