heat loads
Recently Published Documents


TOTAL DOCUMENTS

594
(FIVE YEARS 126)

H-INDEX

32
(FIVE YEARS 5)

Author(s):  
Cedric Reux ◽  
Carlos Paz-Soldan ◽  
Nicholas W. Eidietis ◽  
Michael Lehnen ◽  
Pavel Aleynikov ◽  
...  

Abstract Runaway electrons created during tokamak disruptions pose a threat to a reliable operation of future larger machines. Experiments using Shattered Pellet Injection (SPI) have been carried out at the JET tokamak to investigate ways to prevent their generation or suppress them if avoidance is not sufficient. Avoidance is possible if the SPI contains a sufficiently low fraction of high-Z material, or if it is fired early in advance of a disruption prone to runaway generation. These results are consistent with previous similar findings obtained with Massive Gas Injection. Suppression of an already accelerated beam is not efficient using High-Z material, but deuterium leads to harmless terminations without heat loads. This effect is the combination of a large MHD instability scattering runaway electrons on a large area and the absence of runaway regeneration during the subsequent current collapse thanks to the flushing of high-Z impurities from the runaway companion plasma. This effect also works in situations where the runaway beam moves upwards and undergoes scraping-off on the wall.


2022 ◽  
Author(s):  
Shuyu Dai ◽  
Defeng Kong ◽  
Vincent Chan ◽  
Liang Wang ◽  
Yuhe Feng ◽  
...  

Abstract The numerical modelling of the heat flux distribution with neon impurity seeding on CFETR has been performed by the three-dimensional (3D) edge transport code EMC3-EIRENE. The maximum heat flux on divertor targets is about 18 MW m-2 without impurity seeding under the input power of 200 MW entering into the scrape-off layer. In order to mitigate the heat loads below 10 MW m-2, neon impurity seeded at different poloidal positions has been investigated to understand the properties of impurity concentration and heat load distributions for a single toroidal injection location. The majority of the studied neon injections gives rise to a toroidally asymmetric profile of heat load deposition on the in- or out-board divertor targets. The heat loads cannot be reduced below 10 MW m-2 along the whole torus for a single toroidal injection location. In order to achieve the heat load mitigation (<10 MW m-2) along the entire torus, modelling of sole and simultaneous multi-toroidal neon injections near the in- and out-board strike points has been stimulated, which indicates that the simultaneous multi-toroidal neon injections show a better heat flux mitigation on both in- and out-board divertor targets. The maximum heat flux can be reduced below 7 MWm-2 on divertor targets for the studied scenarios of the simultaneous multi-toroidal neon injections.


2022 ◽  
Vol 1216 (1) ◽  
pp. 012011
Author(s):  
A A Genbach ◽  
H I Beloev ◽  
D Yu Bondartsev ◽  
N A Genbach

Abstract This paper shows the problem with heat exchange depending on units of thermal power plant equipment. The type of structures is determined and the heat flow for different pressures is proposed. Studies are developed for the condition of the heat exchange surface. Devices with porous coatings eliminate the development of cracks in the components and units of TPP equipment have been suggested. The research is applicable to gas turbine units of TPP. Comparable capillary-porous and flow systems have high reliability, but the former allowed the reduction of coolant consumption dozens up to 80 times. The results show that at higher heat loads it is suitable to use in porous surfaces to control the cooling surface. Evaluation of capillary-porous structures has shown their advantages over traditional cooling systems.


2021 ◽  
Vol 173 ◽  
pp. 112827
Author(s):  
V. Shah ◽  
J.A.W. van Dommelen ◽  
S.E.S. Heijkoop ◽  
M.A. Oude Vrielink ◽  
M.G.D. Geers

2021 ◽  
Vol 2116 (1) ◽  
pp. 012077
Author(s):  
Rajesh Akula ◽  
Chakravarthy Balaji

Abstract The goal of this paper is to investigate the usefulness of Phase Change Material based heat sinks in power surge operations. Experiments have been carried out on a PCM based heat sink for different fill ratios (0, 33, 66, and 99%) of the PCM and different orientations (0, 90, 180°) of the heat sink under constant and power surge heat loads. The heat sink with a fill ratio of 0% is considered as the baseline case for comparison. The heat sink with a fill ratio of 66% at 0° orientation recorded lower temperatures among all the fill ratios and orientations under both constant and power surge heat loads. Partial filling (66% fill ratio) of the PCM in the cavity is more effective than complete filling (99% fill ratio) in handling both constant and power surge heat loads.


2021 ◽  
Vol 882 (1) ◽  
pp. 012054
Author(s):  
Nendaryono Madiutomo ◽  
Willy Hermawan ◽  
Weningsulistri ◽  
Madya Pamungkas

Abstract Rock permeability value is one of the most significant rock’s physical properties that affect groundwater influx processes in underground coal gasification (UCG). This value of rock permeability (K), namely the vertical permeability of flanking rocks (Kv) and horizontal permeability of coal (Kh). The purpose of this study was to determine the extent of the influence of the value of rock permeability on the potential of groundwater influx. The effect of rock permeability on groundwater influx into the UCG gasification reactor cavity in the presence of thermal loads and mineral composition content is large and significant to consider. Based on the resistance to heat loads, the type of sandstone lithology is relatively more resistant compared to siltstone and claystone lithology.


Author(s):  
Guangming Xu ◽  
Rongjian Xie ◽  
Nanxi Li ◽  
Cheng Liu

Abstract Two kinds of new refrigerant-R1234ze (E) and R245fa were discussed as substitutes or supplements to traditional working fluids of loop heat pipes based on their favorable thermophysical properties and characteristics such as being safe and environmentally friendly. Thermal characteristics of a loop heat pipe with sintering copper wick at different charging ratios were experimentally investigated under variable heat loads. The results showed that the optimal charging ratio in the loop heat pipe range from 65% to 70%, and at this charging level, the R1234ze(E) system had better start-up response, while the R245fa system presented a stronger heat transfer capacity. The characteristic temperature of R1234ze(E) system was below 35 °C, and the corresponding thermal resistance was 0.08 K/W ~ 1.62 K/W under heat loads ranging from 5 W to 40 W. The thermal resistance of the R245fa system was 0.18 K/W ~ 0.91 K/W under heat loads of 10 W ~ 60 W, and the operating temperature was below 60 °C. The loop heat pipes charged with the proposed new refrigerants exhibit superb performance in room temperature applications, making them beneficial for enhancing the performance of electronics, and could provide a distinctive choice for the cooling of small-sized electronics especially.


2021 ◽  
Author(s):  
Marco Minissale ◽  
Alan Durif ◽  
Guillaume Kermouche ◽  
Marianne Richou ◽  
Laurent Gallais
Keyword(s):  