scholarly journals Theoretical and Experimental Study for the Effect of Mass Flow Rate and concentration ratio of PTC Close Type Solar Collector in Kirkuk City

2017 ◽  
Vol 12 (1) ◽  
pp. 372-395
Author(s):  
Ahmad H. Ahmad ◽  
Ahmad S.Mohammad ◽  
Hussain S. Akbar
2018 ◽  
Vol 22 (1 Part B) ◽  
pp. 487-494 ◽  
Author(s):  
Aminreza Noghrehabadi ◽  
Ebrahim Hajidavaloo ◽  
Mojtaba Moravej ◽  
Ali Esmailinasab

Solar collectors are the key part of solar water heating systems. The most widely produced solar collectors are flat plate solar collectors. In the present study, two types of flat plate collectors, namely square and rhombic collectors are experi?mentally tested and compared and the thermal performance of both collectors is investigated. The results show both collectors have the same performance around noon (?61%), but the rhombic collector has better performance in the morning and afternoon. The values for rhombic and square collectors are approximately 56.2% and 53.5% in the morning and 56.1% and 54% in the afternoon, respectively. The effect of flow rate is also studied. The thermal efficiency of rhombic and square flat plate collectors increases in proportion to the flow rate. The results indicated the rhombic collector had better performance in comparison with the square collector with respect to the mass-flow rate.


Author(s):  
Min Zhang ◽  
Dara W. Childs

Abstract With the increasing demand of the oil & gas industry, many pump companies are developing multiphase pumps, which can handle liquid-gas flow directly without separating the liquid from a mixed flow. The see-through labyrinth seal is one of the popular types of non-contact annular seals that act as a balancing piston seal to reduce the axial thrust of a high-performance centrifugal pump. The see-through labyrinth seal also generates reaction forces that can significantly impact the rotordynamic performance of the pump. Multiphase pumps are expected to operate from pure-liquid to pure-gas conditions. Zhang et al. (2019) conducted a comprehensive experimental study on the performance (leakage and rotordynamic coefficients) of a see-through labyrinth seal under mainly-gas conditions. This paper continues Zhang et al.’s (2019) research and studies the performance of the see-through TOS (tooth-on-stator) labyrinth seal under mainly-liquid conditions. The test seal’s inner diameter, length, and radial clearance are 89.256 mm, 66.68 mm, and 0.178 mm, respectively. The test fluid is a mixture of air and silicone oil (PSF-5cSt), and the inlet GVF (gas volume fraction) varies from zero to 12%. Tests are conducted at an exit pressure of 6.9 bars, an inlet temperature of 39.1 °C, three pressure drops PDs (27.6 bars, 34.5 bars, and 48.3 bars), and three rotating speeds ω (5 krpm, 10 krpm, and 15 krpm). The seal is always concentric with the rotor, and there is no intentional fluid pre-rotation at the seal inlet. The air presence in the oil flow significantly impacts the leakage as well as the dynamic forces of the test seal. The first air increment (increasing inlet GVF from 0% to 3%) slightly increases the leakage mass flow rate, while further air increments steadily decrease the leakage mass flow rate. For all test conditions, the leakage mass flow rate does not change as ω increases from 5 krpm to 10 krpm but decreases as ω is further increased to 15 krpm. The reduction in the leakage mass flow rate indicates that there is an increase in the friction factor, and there could be a highly possible flow regime change as ω increases from 10 krpm to 15 krpm. For ω ≤ 10 krpm, effective stiffness Keff increases as inlet GVF increases. Keff represents the test seal’s total centering force on the pump rotor. The increase of Keff increases the seal’s centering force and would increase the pump rotor’s critical speeds. Ceff indicates the test seal’s total damping force on the pump rotor. For ω ≤ 10 krpm, Ceff first decreases as inlet GVF increases from zero to 3%, and then remains unchanged as inlet GVF is further increased to 12%. For ω = 15 krpm, Keff first increases as inlet GVF increases from zero to 3% and then decreases as inlet GVF is further increased. As inlet GVF increases, Ceff steadily decreases for ω = 15 krpm.


2016 ◽  
pp. 437-444
Author(s):  
Yusuke Shintani ◽  
Tsutomu Nagaoka ◽  
Yoshikazu Deguchi ◽  
Kazunori Harada

A new design of solar still consist of flat plate solar collector, heat exchanger and cooling tower, was built and tested under Iraq weather at March. The still was tested under different mass flow rate of brackish water entering the flate plate solar collector, ranging from 0.01 to 0.015 kg/s. The volume flow rate of air through cooling tower was 0.0195 m3 /s. A full details of overall system as well as for system components exergy analysis were achieved. It was found that the maximum daily exergy efficiency of the still is less than 1%. While the maximum hourly exergy efficiency and maximum productivity for such combination were 3.46 kg/day and 1.6% , respectively, when the mass flow rate of brackish water was 0.013 kg/s.


2021 ◽  
Vol 143 (1) ◽  
Author(s):  
Min Zhang ◽  
Dara W. Childs

Abstract With the increasing demand of the oil and gas industry, many pump companies are developing multiphase pumps, which can handle liquid–gas flow directly without separating the liquid from a mixed flow. The see-through labyrinth seal is one of the popular types of noncontact annular seals that act as a balancing piston seal to reduce the axial thrust of a high-performance centrifugal pump. The see-through labyrinth seal also generates reaction forces that can significantly impact the rotordynamic performance of the pump. Multiphase pumps are expected to operate from pure-liquid to pure-gas conditions. Zhang and Childs (2019) (Zhang, M., and Childs, D., 2019, “A Study on the Leakage and Rotordynamic Performance of a Long Labyrinth Seal Under Mainly-Air Conditions,” ASME J. Eng. Gas Turbines Power, 141(12), p. 121024) conducted a comprehensive experimental study on the performance (leakage and rotordynamic coefficients) of a see-through labyrinth seal under mainly gas conditions. This paper continues Zhang and Childs (2019) (Zhang, M., and Childs, D., 2019, “A Study on the Leakage and Rotordynamic Performance of a Long Labyrinth Seal Under Mainly-Air Conditions,” ASME J. Eng. Gas Turbines Power, 141(12), p. 121024) research and studies the performance of the see-through tooth-on-stator labyrinth seal under mainly liquid conditions. The test seal's inner diameter, length, and radial clearance are 89.256 mm, 66.68 mm, and 0.178 mm, respectively. The test fluid is a mixture of air and paper silicone oil (PSF-5cSt), and the inlet gas volume fraction (GVF) varies from zero to 12%. Tests are conducted at an exit pressure of 6.9 bars, an inlet temperature of 39.1 °C, three pressure drops (PDs) (27.6 bars, 34.5 bars, and 48.3 bars), and three rotating speeds ω (5 krpm, 10 krpm, and 15 krpm). The seal is always concentric with the rotor, and there is no intentional fluid prerotation at the seal inlet. The air presence in the oil flow significantly impacts the leakage as well as the dynamic forces of the test seal. The first air increment (increasing inlet GVF from 0% to 3%) slightly increases the leakage mass flow rate, while further air increments steadily decrease the leakage mass flow rate. For all test conditions, the leakage mass flow rate does not change as ω increases from 5 krpm to 10 krpm but decreases as ω is further increased to 15 krpm. The reduction in the leakage mass flow rate indicates that there is an increase in the friction factor, and there could be a highly possible flow regime change as ω increases from 10 krpm to 15 krpm. For ω ≤ 10 krpm, effective stiffness Keff increases as inlet GVF increases. Keff represents the test seal's total centering force on the pump rotor. The increase of Keff increases the seal's centering force and would increase the pump rotor's critical speeds. Ceff indicates the test seal's total damping force on the pump rotor. For ω ≤ 10 krpm, Ceff first decreases as inlet GVF increases from zero to 3%, and then remains unchanged as inlet GVF is further increased to 12%. For ω = 15 krpm, Keff first increases as inlet GVF increases from zero to 3% and then decreases as inlet GVF is further increased. As inlet GVF increases, Ceff steadily decreases for ω = 15 krpm.