scholarly journals Analysis of Antimicrobial Compound in Ziziphus Mauritiana Extract using Attenuated Total Reflection-Fourier Transform Infrared (ATR-FTIR)

Author(s):  
Khairina Idris ◽  
Nurhanini Nahlul Muna Yusof ◽  
Tg Ainul Farha Tg Abdul Rahman ◽  
Liyana Amalina Adnan ◽  
A’wani Aziz Nurdalila Aziz

Ziziphus mauritiana is locally known as Bidara that belongs to Rhamnaceae family which is a herbal plant that believed originated from Indo-Malaysian region of South-East Asia. It is commonly known for its various benefits as pharmacological such as antioxidants and antimicrobial. In order to prove its efficacy, antimicrobial compound analysis of Ziziphus mauritiana leaf extract was performed using Attenuated total reflection-fourier transform infrared (ATR-FTIR). The spectrum and wavelength obtained can be used to identify the functional group and thus, the antimicrobial compound was discovered present in the plant. A liquid-liquid extraction had been carried out to obtain the extract of Ziziphus mauritiana leaf sample and rotary evaporator is used to remove the solvent of ethyl acetate. Based on this study, Ziziphus mauritiana leaves do have antimicrobial compounds such as eugenol and vanillin which are one of the antimicrobial agents.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Adam D. Morris ◽  
Camilo L. M. Morais ◽  
Kássio M. G. Lima ◽  
Daniel L. D. Freitas ◽  
Mark E. Brady ◽  
...  

AbstractThe current lack of a reliable biomarker of disease activity in anti-neutrophil cytoplasmic autoantibody (ANCA) associated vasculitis poses a significant clinical unmet need when determining relapsing or persisting disease. In this study, we demonstrate for the first time that attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy offers a novel and functional candidate biomarker, distinguishing active from quiescent disease with a high degree of accuracy. Paired blood and urine samples were collected within a single UK centre from patients with active disease, disease remission, disease controls and healthy controls. Three key biofluids were evaluated; plasma, serum and urine, with subsequent chemometric analysis and blind predictive model validation. Spectrochemical interrogation proved plasma to be the most conducive biofluid, with excellent separation between the two categories on PC2 direction (AUC 0.901) and 100% sensitivity (F-score 92.3%) for disease remission and 85.7% specificity (F-score 92.3%) for active disease on blind predictive modelling. This was independent of organ system involvement and current ANCA status, with similar findings observed on comparative analysis following successful remission-induction therapy (AUC > 0.9, 100% sensitivity for disease remission, F-score 75%). This promising technique is clinically translatable and warrants future larger study with longitudinal data, potentially aiding earlier intervention and individualisation of treatment.


2005 ◽  
Vol 59 (6) ◽  
pp. 724-731 ◽  
Author(s):  
R. N. Phalen ◽  
Shane S. Que Hee

This study developed a method to produce uniform captan surface films on a disposable nitrile glove for quantitation with a portable attenuated total reflection Fourier transform infrared (ATR-FTIR) spectrometer. A permeation test was performed using aqueous captan formulation. Uniform captan surface films were produced using solvent casting with 2-propanol and a 25 mm filter holder connected to a vacuum manifold to control solvent evaporation. The coefficient of variation of the reflectance at 1735 ± 5 cm−1 was minimized by selection of the optimum solvent volume, airflow rate, and evaporation time. At room temperature, the lower to upper quantifiable limits were 0.31–20.7 μg/cm2 ( r = 0.9967; p ≤ 0.05) for the outer glove surface and 0.55–17.5 μg/cm2 ( r = 0.9409; p ≤ 0.05) for the inner surface. Relative humidity and temperature did not affect the uncoated gloves at the wavelength of captan analysis. Glove screening using ATR-FTIR was necessary as a control for between-glove variation. Captan permeation, after 8 hours exposure to an aqueous concentration of 217 mg/mL of Captan 50-WP, was detected at 0.8 ± 0.3 μg/cm2 on the inner glove surface. ATR-FTIR can detect captan permeation and can determine the protectiveness of this glove in the field.


Sign in / Sign up

Export Citation Format

Share Document