scholarly journals Quadrupole Time-of-Flight Mass Spectrometry: A Paradigm Shift in Toxicology Screening Applications

2019 ◽  
Vol 40 (3) ◽  
pp. 135-146 ◽  
Author(s):  
Darren Allen ◽  
Brett McWhinney

The screening of biological samples for the presence of illicit or legal substances is an important frontline tool in both clinical and forensic toxicology. In the clinical setting, drug screening is a useful tool for the clinician in improving patient care and guiding treatment. Analytical approaches for the screening of drugs in biological samples are extensive and well documented, though many rapid screening techniques often lack appropriate sensitivity and specificity, requiring careful clinical interpretation. The continuous emergence of new psychoactive substances presents a considerable analytical challenge in maintaining up-to-date methods for the detection of relevant drugs. Adapting and validating methods for the detection of new substances can be a complicated and costly undertaking. There is also a considerable lag time between the emergence of new drugs and the release of commercial assays for detection. Quadrupole time-of-flight mass spectrometry (Q-TOF-MS) has gained considerable attention over the last decade as an analytical technique that is capable of meeting the challenges of a rapidly changing drug landscape. Exhibiting both high sensitivity and specificity in drug detection, Q-TOF-MS also allows methods to be rapidly updated for newly emerging psychoactive agents. The coupling of Q-TOF-MS with techniques such as liquid or gas chromatography can provide both rapid and comprehensive screening solutions that are gaining popularity in the clinical laboratory setting.

2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Junmei Ma ◽  
Qiang Li ◽  
Sufang Fan ◽  
Liangna He ◽  
Lei Sun ◽  
...  

A ultrahigh performance liquid chromatography coupled with quadrupole-time of flight mass spectrometry (UPLC-Q-TOF/MS) method was developed for simultaneous determination of 8 endogenous alkaloid compounds in Boletus. Boletus samples were extracted by 50% (V/V) methanol-water solution, then separated by CORTECS UPLC HILIC column using a binary solvent system by gradient elution. The analytes were determined by Q-TOF/MS in TOF MS and information dependent acquisition (IDA)-MS/MS mode. The results showed that mass accuracy error of the 8 endogenous alkaloids were lower than 5.0 × 10−6, good linear relationship was got in range of 0.2–500 μg/L, and correlation coefficient was higher than 0.9990. The limit of detection was in the range of 0.002–0.100 mg/kg and the limit of quantification was in the range of 0.004–0.200 mg/kg. Recovery of the method was in range of 80.1%–101.5% with spike levels of 0.004–2.00 mg/kg, relative standard deviations were lower than 10%. The method was simple, specific, and reliable. It could be used for the rapid screening and quantitative analysis of 8 endogenous alkaloids in Boletus.


Sign in / Sign up

Export Citation Format

Share Document