scholarly journals Development and Validation of Bioanalytical HPLC Method For Estimation of Telmisartan In Rat Plasma: Application To Pharmacokinetic Studies

2013 ◽  
Vol 11 (2) ◽  
pp. 121-127 ◽  
Author(s):  
Jaydeep M Patel ◽  
Anjali P Dhingani ◽  
Kevin C Garala ◽  
Mihir K Raval ◽  
Navin R Sheth

A simple, specific, sensitive and rapid reversed phase high performance liquid chromatographic (HPLC) method has been developed and validated for the determination of telmisartan in small volumes of rat plasma. Biological sample preparation involving simple extraction with organic solvent, followed by dilution with mobile phase was adopted to eliminate any chromatographic solvent effects. The method was proven to be linear over a plasma concentration range of 10 to 1000 ng/mL with a mean correlation coefficient of 0.9942. The limit of detection and the limit of quantification of the newly developed method were determined to be 1 ng/mL and 10 ng/mL, respectively. The method was successfully applied to assess pharmacokinetic parameters of telmisartan in Wister rats following a single oral dose (1.8 mg/kg, b.w.). The developed method was established as a rapid analytical tool in a pharmacokinetic study as it required short retention time, high precision, sensitivity and small volumes of plasma for analysis. DOI: http://dx.doi.org/10.3329/dujps.v11i2.14562 Dhaka Univ. J. Pharm. Sci. 11(2): 121-127, 2012 (December)

INDIAN DRUGS ◽  
2013 ◽  
Vol 50 (05) ◽  
pp. 48-52
Author(s):  
A Lodhi ◽  
◽  
A Jain ◽  
B. Biswal

A validated high performance liquid chromatographic method was developed for the determination of chromium picolinate in pharmaceutical dosage forms. The analysis was performed at room temperature using a reversed-phase ODS, 5µm (250×4.6) mm column. The mobile phase consisted of acetonitrile: buffer (60:40 V/V) at a flow rate of 0.5 mL/min. The PDA-detector was set at 264 nm. The developed method showed a good linear relationship in the concentration range from 1.5 – 12.5 µg/mL with a correlation coefficient from 0.999. The limit of detection and limit of quantification were 0.0540513 and 0.1637919 µg/mL respectively.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (07) ◽  
pp. 32-37
Author(s):  
Vijaya Lakshmi Marella ◽  
Chaitanya S. N ◽  

A selective and sensitive reverse phase High Performance Liquid Chromatographic method has been developed and validated for the estimation of lornoxicam in bulk, pharmaceutical dosage forms and in dissolution samples. The analysis was performed isocratically on an Inertsil column (250* 4.6 mm, 5 µm) using a mass spectrometric compatible mobile phase of 10 mM ammonium acetate: acetonitrile (50:50 V/V) at a flow rate of 1 mL/min.The detection wavelength was 290 nm. The retention time was found to be 4.573 min for lornoxicam. The linearity of the method has been satisfied with Beer Lambert’s law in the concentration range of 5-25 µg/mL with a correlation coefficient of 0.9988. The mean recoveries assessed for lornoxicam were in the range of 100.39-101.86 %, indicating good accuracy of the method. The limit of detection and limit of quantification were found to be 0.03 and 0.11 µg/mL, respectively. The developed method has been statistically validated in accordance with ICH guidelines and found to be mass spectrometric compatible, simple, precise, and accurate with the prescribed values. Thus, the proposed method was successfully applied for the estimation of lornoxicam in routine quality control analysis of bulk, formulations and in dissolution samples.


INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (09) ◽  
pp. 27-32
Author(s):  
V. S Reddy ◽  
◽  
T. E. G. K. Murthy ◽  
N Usha Rani ◽  
R. S Rao ◽  
...  

A simple, precise, accurate, reproducible, robust reverse phase high-performance liquid chromatographic method was developed for the simultaneous estimation of frovatriptan, almotriptan and zolmitriptan in bulk and pharmaceutical dosage forms. The method was validated as per ICH and FDA guidelines. Analysis of the drugs was performed on Phenomenex Chromosil C-18 (250 x 4.6 mm, 5 mc) column, in an isocratic mode employing methanol, acetonitrile and THF in the ratio of 46:50:04 (v/v/v) as mobile phase. UV-visible detector at 269 nm was found to be suitable for detection. Linearity was observed in the range of 40-100 ppm.The % recovery was found to be 99.51, 99.69 and 99.34 for frovatriptan, almotriptan and zolmitriptan respectively. The % RSD values for method precision was found to be 0.86, 0.65 and 1.28 for frovatriptan, almotriptan and zolmitriptan respectively. Limit of quantification (LOQ) and limit of detection (LOD) values were found to be 0.15, 0.08 and 0.09 ppm. and 0.05, 0.02, 0.03 for frovatriptan, almotriptan and zolmitriptan respectively.


Author(s):  
Sunkara Namratha ◽  
Vijayalakshmi A

Objective: Reversed-phase high-performance liquid chromatographic method (RP-HPLC) was developed for the assessment of lopinavir in the dosage form of tablet.Methods: Chromatogram was run through using Kromosil C18 4.5×150 mm using a mobile phase methanol: water of ratio 65:35% v/v with a rate of flow of 0.8 ml/min, measured by UV spectrometric detection at 265 nm. The method developed was validated in terms of precision, accuracy, linearity, and robustness parameters.Results: Retention time of lopinavir established at 2.482 min and percentage R.S.D of lopinavir found to be 1.0% and 0.5%, respectively. The method shows that good linearity range of 30–150 μg correlation coefficient of lopinavir was 0.997. The limit of detection was 2.97 and limit of quantification was 9.92, respectively. The percent purity of lopinavir was 99.87%.Conclusion: The suggested method (Rp-HPLC) for concurrent assay lopinavir was validated, which is appropriate method for the analysis oflopinavir quantitatively in tablet dosage forms and bulk.


2009 ◽  
Vol 63 (6) ◽  
Author(s):  
Hong Yan ◽  
Pei Xu ◽  
Hai Huang ◽  
Juan Qiu

AbstractA pre-column derivatized high-performance liquid chromatographic (HPLC) method with ultraviolet-visible detection was developed to measure the concentrations of spectinomycin in fermentation broth. Derivatization reagents, 2,4-dinitrophenylhydrazine in acetonitrile (5 mg mL−1) and trifluoroacetic acid in acetonitrile (0.8 mol L−1), were added to an aliquot of the fermentation broth, and the mixture was incubated for 60 min at 70°C. The resulting derivative was separated from other compounds by isocratic elution in a reversed-phase column Zorbax SB-C18 (250 mm × 4.6 mm, 5 µm). Mobile phase consisted of acetonitrile, tetrahydrofuran, and water (φ r = 40: 35: 25) and the flow rate was 1.0 mL min−1. The detection wavelength was 415 nm. The standard curve for spectinomycin sulfate was linear with correlation coefficients of 0.9997 in the range of 25 µg mL−1 to 600 µg mL−1. The relative standard deviation values ranged from 0.43 % to 2.18 % depending on the concentration of samples. The average recovery was 101.5 %. The limit of detection was 50 ng mL−1.


2012 ◽  
Vol 10 (2) ◽  
pp. 67-70
Author(s):  
Abdullah Al Masud ◽  
Mohammad Saydur Rahman ◽  
Towfika Islam ◽  
Saki Sultana ◽  
Moynul Hasan ◽  
...  

A simple, reproducible and efficient reversed phase high performance liquid chromatographic (RPHPLC) method has been developed for the estimation of a recently approved anti allergic drug, amlexanox in oral paste dosage form. The separations were carried out on a Zorbax Eclipse XBD, C18 column (150 x 4.6 mm; 5?m) at a flow rate of 1.50 ml/min. by using mobile phase comprising of mixed buffer (pH adjusted to 6.50) and methanol (50:50 v/v). The injection volume was 10 ?l and the peaks were detected at 244 nm. The linear dynamic range found to be in the concentration range of 15-35 ?g/ml and coefficient of correlation was found to be 0.999. The %RSD value was below 2.0 for intra-day and inter-day precision which indicated that the method was highly precise. The LOD (Limit of detection) and LOQ (Limit of quantitation) were found to be 3.8 ng/ml and 12.5 ng/ml, respectively which revealed that the method was highly sensitive. The percentage recovery of amlexanox ranged from 99.31 to 99.75%, indicating the accuracy of the method and absence of interference from the excipients present in the formulation. The proposed method was simple, fast, accurate and reproducible and hence can be applied for routine quality control operations of amlexanox in oral paste dosage form. Key words: Amlexanox, Anti allergic, RP-HPLC, LOD, LOQ. DOI: http://dx.doi.org/10.3329/dujps.v10i2.11782 Dhaka Univ. J. Pharm. Sci. 10(2): 67-70, 2011 (December)


2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
J. Álvarez-Fuentes ◽  
L. Martín-Banderas ◽  
I. Muñoz-Rubio ◽  
M. A. Holgado ◽  
M. Fernández-Arévalo

A simple, fast, and reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for determining of a cannabinoid derivate, which displays potent antihyperalgesic activity, 1-naphthalenyl[4-(pentyloxy)-1-naphthalenyl]methanone (CB13) into PLGA nanoparticles. Separation was achieved in a C18 column using a mobile phase consisting of two solvents: solvent A, consisting of acetonitrile : water : acetic acid (75 : 23.7 : 1.3 v/v), and solvent B, consisting of acetonitrile. An isocratic method (70 : 30 v/v), with a flow rate of 1.000 mL/min, and a diode array detector were used. The developed method was precise, accurate, and linear over the concentration range of analysis with a limit of detection and a limit of quantification of 0.5 and 1.25 μg/mL, respectively. The developed method was applied to the analysis of CB13 in nanoparticles samples obtained by three different procedures (SEV, FF, and NPP) in terms of encapsulation efficiency and drug release. Nanoparticles size and size distribution were also evaluated founding that NPP method presented the most lowest particle sizes with narrow-size distribution (≈320 nm) and slightly negative zeta potential (≈−25 mV) which presumes a suitable procedure for the synthesis of PLGA-CB13 nanoparticles for oral administration.


Author(s):  
Khater Ahmed Saeed AL-Japairai ◽  
Bappaditya Chatterjee ◽  
Syed Mahmood ◽  
Samah Hamed Almurisi

The telmisartan was determined in a rat plasma using developed and validated a reversed-phase high performance liquid chromatographic (HPLC). The pre-treatment of the plasma sample involving liquid-liquid extraction using ethanol as the extracting solvent. The HPLC method validation has been shown a linear calibration curve over a plasma concentrations range of 0.7 to 10µg/mL with a correlation coefficient of 0.9979, the limit of detection and the limit of quantification were determined to be 0.025µg/ml and 0.07µg/ml, respectively. The precision and accuracy were in an acceptable limit. The pharmacokinetic parameters of telmisartan were adequately evaluated following a single oral dose (4mg/kg) in Sprague-Dawley rats. The results observed conclude that the developed bioanalytical HPLC method is appropriate and applicable as an analytical tool in the pharmacokinetic study of telmisartan.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (09) ◽  
pp. 68-73
Author(s):  
K Vijaya Sri ◽  
M. Shiva Kumar ◽  
M. A. Madhuri ◽  
Suresha K. ◽  

In this study, a high-performance liquid chromatographic method (HPLC) was developed, validated and applied for the determination of raltegravir in biological sample like saliva. Liquid- liquid extraction was performed for isolation of the drug and elimination of saliva interferences. Samples of saliva was extracted with 50µL of ortho phosphoric acid and 3ml of methanol was added and spiked with raltegravir. The chromatographic separation was performed on Agilent Eclipse C18 (100 mm × 4.6 mm, 3.5µm) column, by using 80:20 v/v acetonitrile: water as a mobile phase under isocratic conditions at a flow rate of 1.0 mL/min for UV detection at 240 nm. Retention time of raltegravir was found to be 1.030 min. Linearity was found to be in the range of 25-1000 ng/mL with regression equation y = 13864x + 40495 and correlation coefficient 0.999. The low % RSD value indicates the method is accurate and precise. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.76 and 2.28 ng/mL, respectively. It can be concluded that this validated HPLC method is easy, precise, accurate, sensitive and selective for determination of raltegravir in saliva.


Author(s):  
VEERASWAMI B ◽  
NAVEEN VMK

Objective: The present paper describes a simple, accurate, and precise reversed-phase high-performance liquid chromatography (HPLC) method for rapid and simultaneous quantification of dolutegravir (DTG) and rilpivirine (RPV) in bulk and pharmaceutical dosage form and rat plasma. Methods: The chromatographic separation was achieved on Phenomenex C18 (150x4.6mm, 5μm). Mobile phase contained a mixture of 0.1% Ortho phosphoric acid and acetonitrile in the rato of 60:40 v/v, flow rate 1.0ml/min and ultraviolet detection at 262nm. Results: The retention time of DTG and RPV was 4.35 min and 7.73 min, respectively. The proposed method shows a good linearity in the concentration range of 10–150 μg/ml for DTG and 5–75 μg/ml for RPV under optimized conditions. Precision and recovery study results are in between 98 and 102%. In the entire robustness conditions, percentage relative standard deviation is <2.0%. Degradation has minimum effect in stress condition and solutions are stable up to 24 h. DTG and RPV drugs are release 98% at 2 h in rat body. Conclusion: This method is validated for different analytical performance parameters like linearity. Precision, accuracy, limit of detection, limit of quantification, robustness, and pharmacokinetic study were determined according to the International Conference of Harmonization (ICH) Q2B guidelines. All the parameters of validation were found in the acceptance range of ICH guidelines. The same method is also applied for plasma samples study in bioanalytical work.