scholarly journals Application of PCR for the detection of bovine tuberculosis in cattle

1970 ◽  
Vol 9 (1) ◽  
pp. 73-78 ◽  
Author(s):  
Q Nahar ◽  
M Pervin ◽  
MT Islam ◽  
MAHNA Khan

The present study was carried out for the detection and identification of bovine tuberculosis (bTB) using polymerase chain reaction (PCR). A total of 10 suspected cattle of Savar and BAU dairy farm were examined. Lymphnode biopsy, nasal swabs and blood were collected. Smears from lymphnode biopsy and nasal swabs were made onto clear slides and stain with acid fast staining. Portion of lymohnodes were preserved at -200C and extracted DNA for PCR analysis. Portion of lymphnodes and other tissues were also collected in 10% neutral buffered formalin for routine Hematoxilin and Eosin staining and acid fast staining. In this study, acid fast staining of lymphnodes and nasal smears failed to detect acid fast Mycobacterium. The genome of bovine Mycobacterium in the extracted DNA of lymphnodes which used in PCR reaction was amplified and yielded 600 bp amplicon. This study suggests that, the PCR technique is a useful and rapid diagnostic tool for the identification of bovine TB in dairy cattle. Amplification technology offers the potential for the diagnosis of TB in a few hours with a high degree of sensitivity and specificity. Keywords: Bovine TB; acid fast; PCR DOI: http://dx.doi.org/10.3329/jbau.v9i1.8747 JBAU 2011; 9(1): 73-78

Author(s):  
Ülkü Karatekeli ◽  
Beytullah Kenar

Background: Contagious agalactia causes significant economic losses. The aim of this study is to investigate the presence of contagious agalactia disease in cities of Isparta and Afyonkarahisar, Turkey. Methods: The study includes 45.500 animals in 220 ovine enterprises and samples were taken from those suspected of contagious agalactia disease. 202 animals in the 21 ovine enterprises comprised of 139 goats, 56 sheep, 3 kid goats, 2 goats, 2 lambs in total suspected of the disease were sampled. A total of 289 samples were collected, including 91 milk samples, 28 nasal swabs, 101 eye swabs, 8 joint fluids and 61 ear swabs. The isolates obtained after incubation were identified with polymerase chain reaction by using specific primers to assess film and spot formation, glucose fermentation, growth inhibition tests. Result: Three Mycoplasma spp. isolates obtained from 28 nasal swabs turned out to be negative for M. agalactiae after PCR analysis. Colony morphology, biochemical tests and growth inhibition tests revealed that one agent was M. arginine and the two factors were identified as M. ovipneumoniae with centerless colony morphology. The obtained results were confirmed with the polymerase chain reaction. None of the four factors causing contagious agalactia were isolated and identified.


2008 ◽  
Vol 60 (3) ◽  
pp. 263-271 ◽  
Author(s):  
Catherine Dunyach ◽  
Sébastien Bertout ◽  
Cécile Phelipeau ◽  
Pascal Drakulovski ◽  
Jacques Reynes ◽  
...  

LWT ◽  
2015 ◽  
Vol 63 (1) ◽  
pp. 714-719 ◽  
Author(s):  
Sahilah Abd Mutalib ◽  
Nursheila Mustafa Muin ◽  
Aminah Abdullah ◽  
Osman Hassan ◽  
Wan Aida Wan Mustapha ◽  
...  

Author(s):  
Jun-Hyung Lim ◽  
Sang Hwan Nam ◽  
Jongwoo Kim ◽  
Nam Hoon Kim ◽  
Gun-Soo Park ◽  
...  

Abstract In this study, a three-stage bioaerosol sampler with a sampling flow rate of 170 L/min was designed and fabricated for sampling the bioaerosols released during human breathing and coughing, and its performance was evaluated. The sampler was constructed using a cyclone separator with a cutoff size of 2.5 µm as a preseparator, a multi-nozzle virtual impactor with a cutoff size of 0.34 µm as an aerosol concentrator, and a BioSampler, which is a commercial product, for collecting bioaerosols in a collection fluid. The collection efficiency of the sampler was evaluated through simulations and experiments. Only particles with sizes of 0.1-4 µm were selectively collected in the collection fluid. Bacteriophage bioaerosols were sampled using the developed sampler and ACD-200 Bobcat sampler, which is a commercial product. The amounts of collected bacteriophages were compared using the polymerase chain reaction (PCR) technique. The sampling performance of the developed sampler was similar to that of the ACD-200 Bobcat sampler. Moreover, the developed sampler showed its ability to sample bioaerosols of a specific size-range and collect them directly in a collection fluid for the PCR analysis. Therefore, the developed sampler is expected to be useful for indoor environmental monitoring by effectively sampling the bioaerosols released indoors during human breathing and coughing.


2009 ◽  
Vol 27 (36) ◽  
pp. 6094-6100 ◽  
Author(s):  
Lindsey Goff ◽  
Karin Summers ◽  
Sameena Iqbal ◽  
Jens Kuhlmann ◽  
Michael Kunz ◽  
...  

Purpose The randomized First-Line Indolent Trial (FIT) was conducted in patients with advanced follicular lymphoma (FL), to evaluate the safety and efficacy of yttrium-90 (90Y) ibritumomab tiuxetan given as consolidation of complete or partial remission. This study of minimal residual disease was undertaken in parallel, to determine the rate of conversion from bcl-2 polymerase chain reaction (PCR) –detectable to –undetectable status and the corresponding effect on progression-free survival (PFS). Patients and Methods Blood samples from 414 patients (90Y-ibritumomab, n = 208; control, n = 206) were evaluated using real-time quantitative polymerase chain reaction (RQ-PCR); 186 were found to have the bcl-2 rearrangement and were thus eligible for inclusion in the RQ-PCR analysis. Results Overall, 90% of treated patients converted from bcl-2 PCR–detectable to –undetectable disease status, compared with 36% in the control group. Treatment significantly prolonged median PFS in patients converting to bcl-2 PCR-undetectable status (40.8 v 24.0 months in the control group; P < .01, hazard ratio [HR], 0.399). In patients who had bcl-2 PCR-detectable disease at random assignment, treatment significantly prolonged median PFS (38.4 v 8.2 months in the control group; P < .01, HR, 0.293). Conclusion Eradication of PCR-detectable disease occurred more frequently after treatment with 90Y-ibritumomab tiuxetan and was associated with prolongation of PFS.


2018 ◽  
Vol 48 (6) ◽  
Author(s):  
Marcelo Marques da Silveira ◽  
Stéfhano Luis Cândido ◽  
Karin Rinaldi dos Santos ◽  
Maerle Oliveira Maia ◽  
Roberto Lopes de Souza ◽  
...  

ABSTRACT: Sepsis is characterized by the presence of organ dysfunction secondary to the dysregulated systemic inflammatory response associated with an infection, and has high mortality rates. Traditional diagnostic techniques based on non-microbiological isolation are time-consuming and may delay treatment. Thus, this study aimed to compare bacterial and fungal broad-range polymerase chain reaction (PCR) and blood culture for diagnosis of sepsis in dogs. Blood samples from 88 dogs with suspected sepsis were analyzed by blood culture, and PCR to detect bacterial and fungal DNA. On blood culture, 20 (22.7%) samples tested positive for bacterial isolates; however, none tested positive for fungi. Through PCR analysis, bacterial DNA was detected in 46 (52.3%) animals, whereas fungal DNA was present in one (1.1%) sample. Our results showed that PCR-based testing has important diagnostic value for canine blood infections because it has a shorter turnaround time and higher sensitivity than traditional blood culture.


2021 ◽  
Vol 6 (2) ◽  
pp. 115-124
Author(s):  
V. Zyuzin ◽  
◽  
O. Tuzova ◽  
U. Frenkel ◽  
Muntian L. ◽  
...  

The purpose of the study. The article covers the issues of genotyping of listeria by polymerase chain reaction (PCR) and its epidemiological significance. It is known that molecular genetic methods allow to detect specific microbial pathogens, virulence markers, antimicrobial resistance genes faster and with greater sensitivity than traditional culture methods. Therefore, the development of detection methods and genotyping by polymerase chain reaction (PCR) is relevant. Materials and methods. For the detection and genotyping of Listeria, the technology of DNA chips is becoming increasingly important, which can significantly expand the possibilities of molecular detection. Chip technology can be used to simultaneously identify a whole range of pathogenic microorganisms, to determine genetic virulence markers, the relationship to antibiotics, subtyping, as well as to determine the quality of microorganisms in samples. A simplified version of DNA chip technology is multiplex (numerical) PCR, which is used to detect and genotype listeria. Studies have shown that to detect Listeria spp. using a polymerase chain reaction, it is advisable to use the gene iap (invasive associated protein), known for 6 species of listeria, which encodes a protein P 60 that is common to all species of listeria, including L.murrayi. Computer analysis revealed areas with 100% homology, from which primers were selected for PCR detection of all types of listeria. Areas of genomes characterized by 100% homology were selected for further analysis and labeling of primer sets. The sequences of the constructed primers List 1 and List 2 allowed to identify 6 species of Listeria (L. monocytogenes, L. innocua, L. ivanovii, L. grayi, L. seeligeri, L. welshimeri). Increasing the length of the primer leads to the increasing of specificity of PCR analysis. The greater the length of the primer, the smaller the specific gravity of one error of the unpaired nucleotide. The degree of primer homology is a key parameter that indicates the "quality" of a set of primers. Results and discussion. It is established that a significant disadvantage of the vast majority diagnosed using PCR test systems is the lack of internal control of amplification. The negative result of PCR analysis may be due to the absence in the clinical material of a fragment of the Listeria genome, and the fact that the PCR product was not synthesized for other reasons. They may be as the following ones: operator errors, erroneously determined reaction mixture concentrations and PCR temperature parameters. False-negative results can also be caused by factors that inhibit thermostable DNA polymerase. In its turn, such inhibition of the enzyme responsible for amplification is caused by a very large amount of DNA - template, pre-treatment of clinical samples. It has been shown that 80% of clinical specimens contain a substance that inhibits DNA polymerase. Therefore, it is necessary to use internal control, the positive result of the reaction of which indicates the successful amplification, that is the absence of false positive results. Conclusion. There are several reasons why the accuracy of PCR analysis does not reach 100%. Accuracy depends on the technology (variety) of PCR - the method used (ordinary or fluorescent), detection of amplicons, PCR homogeneous or nested, nested in one test tube or in two test tubes, as well as the level of quality of the survey (primarily on the technical parameters of the amplifier). The test systems used can be used for PCR detection and are recommended as standard primer sets for the detection and cross-species testing of listeria, which is important for the timely implementation of appropriate anti-epidemic measures in listeriosis


Sign in / Sign up

Export Citation Format

Share Document