scholarly journals Development of a Simple, Sensitive and Rapid Quantitative Analytical Method for Lomefloxacin by High Performance Liquid Chromatography

1970 ◽  
Vol 4 (1) ◽  
pp. 69-73 ◽  
Author(s):  
Mohammad Shah Amran ◽  
Mohammad Rumman Hossain ◽  
Farhad Mohammad Amjad ◽  
Sania Sultana ◽  
Mohammad Abdullahil Baki ◽  
...  

An attempt has been made to develop a simple, sensitive and rapid high performance liquid chromatographic (HPLC) method of analysis for lomefloxacin as in pharmaceutical dosage form using 0.025 M phosphoric acid and acetonitrile (80:20) as mobile phases. The mobile phase was used as solvents to dissolve lomefloxacin and 0.0122 mg/mL stock solution was prepared. Lomefloxacin solution was scanned with UV-spectrophotometer and the absorption maximum (λmax) was found to be 287 nm. This method was successfully applied to five eye drop dosage forms of lomefloxacin encoded as pp1, pp2, pp3, pp4 and pp5 marketed by five different pharmaceutical companies and the result was found to be satisfactory and reproducible. The method was validated by spiked recovery experiments and shown to be linear for lomefloxacin. The method can be used for routine analysis in both research laboratories, and pharmaceutical and chemical industries to analyze the drugs and chemicals without any interference by the excipients.   Key words: Lomefloxacin; HPLC; Analysis; Reproducible. DOI: http://dx.doi.org/10.3329/sjps.v4i1.8871 SJPS 2011; 4(1): 69-73

Author(s):  
DYADE GK ◽  
SAWANT RL

Objective: A reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the simultaneous estimation of amlodipine besylate (AD) and valsartan (VAL) in pharmaceutical dosage form, and rosuvastatin (RV) and VAL from the bulk mixture. Method: Chromatographic separation was performed on RP-C18 column. The optimized unique mobile phase (acetonitrile:water and pH adjusted to 4.8 with acetic acid) was pumped at a flow rate of 0.8 ml/min in the ratio of 75:25% v/v, and the eluents were monitored at 245 nm. Results: The assay was performed with tablet and percentage of assay was found to 101.39 for AD and 100.05 for VAL, respectively, and with bulk mixture, percentage of assay was found to 99.58 for RV and 100.32 for VAL, respectively. Linearity was obtained in the concentration range of 1–12 μg/ml for AD, 5–50 μg/mL for VAL, and 2–20 μg/ml for RV. The method was statistically validated and RSD was found to be <2%, indicating high degree of accuracy and precision of the proposed RP-HPLC method. Conclusions: The method suggests usefulness of unique mobile phase during the estimation of two or more multicomponent dosage forms. Due to its simplicity, rapidness, high precision, and accuracy, the proposed RP-HPLC method can be applied for simultaneous determination of AD and VAL in pharmaceutical dosage form, and RV and VAL in bulk mixture.


Author(s):  
Sherif A. Abdel- Gawad ◽  
Aymen Khalid Al Suwailem ◽  
Sami Salem AlShowiman

Aims: The studied drug is lacking the presence of chromophore so a reaction with NBD-Cl is optimized to facilitate its chromatographic detection, so the main aim of the work is to quantify pamidronate in a sensitive and accurate way either in bulk or dosage forms. Methodology: The quantification of this group of drugs is a challenging task as they lack the presence of chromophore groups in their structure. The proposed method depends on the chromatographic quantification of the studied drug after its derivatization via its reaction with 4-Chloro-7-nitro-2,1,3-benzoxazole and the product is separated on ODS C18 column (5 µm, 15 cm x 5 mm, i.d.) as a stationary phase and methanol : water (8:2, v/v) as a mobile phase. The flow rate was 1 ml/min. Results: The studied drug can be determined in the range of 900 - 3000 ng/mL after optimizing the assay conditions to get optimum stationary – mobile phases match. Method validation is performed according to USP-guidelines and different validation parameters like, linearity, accuracy, precision and robustness are calculated and found to be excellent. Conclusion: The proposed method is accurate, sensitive and can be applied for the routine analysis of pamidronate in quality control laboratories.


INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (09) ◽  
pp. 27-32
Author(s):  
V. S Reddy ◽  
◽  
T. E. G. K. Murthy ◽  
N Usha Rani ◽  
R. S Rao ◽  
...  

A simple, precise, accurate, reproducible, robust reverse phase high-performance liquid chromatographic method was developed for the simultaneous estimation of frovatriptan, almotriptan and zolmitriptan in bulk and pharmaceutical dosage forms. The method was validated as per ICH and FDA guidelines. Analysis of the drugs was performed on Phenomenex Chromosil C-18 (250 x 4.6 mm, 5 mc) column, in an isocratic mode employing methanol, acetonitrile and THF in the ratio of 46:50:04 (v/v/v) as mobile phase. UV-visible detector at 269 nm was found to be suitable for detection. Linearity was observed in the range of 40-100 ppm.The % recovery was found to be 99.51, 99.69 and 99.34 for frovatriptan, almotriptan and zolmitriptan respectively. The % RSD values for method precision was found to be 0.86, 0.65 and 1.28 for frovatriptan, almotriptan and zolmitriptan respectively. Limit of quantification (LOQ) and limit of detection (LOD) values were found to be 0.15, 0.08 and 0.09 ppm. and 0.05, 0.02, 0.03 for frovatriptan, almotriptan and zolmitriptan respectively.


Author(s):  
Zubaidur Rahman ◽  
Vijey Aanandhi M ◽  
Sumithra M

Objective: A simple, novel, sensitive, rapid high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for quantitative determination of atomoxetine HCl (ATH) in bulk and formulations.Methods: The chromatographic development was carried out on RP-HPLC. The column used as Xterra RP 18 (250 mm × 4.6 mm, 5 μ particle size), with mobile phase consisting of methanol: water 80:20 V/V. The flow rate was 1.0 mL/min and the effluents were monitored at 270 nm.Results: The retention time was found to be 5.350 min. The method was validated as per International Conference on Harmonization Guideline with respect to linearity, accuracy, precision, and robustness. The calibration curve was found to be linear over a range of 2–10 μg/mL with a regression coefficient of 0.9999. The method has proved high sensitivity and specificity.Conclusion: The results of the study showed that the proposed RP-HPLC method was simple, rapid, precise and accurate which is useful for the routine determination of ATH in bulk drug and in its pharmaceutical dosage form.


2010 ◽  
Vol 93 (4) ◽  
pp. 1228-1235 ◽  
Author(s):  
Mohamed Walash ◽  
Mohamed Metwally ◽  
Manal Eid ◽  
Rania El-Shaheny

Abstract A micellar HPLC method was developed for analysis of the antiosteoporosis drug risedronate. The analysis was carried out using a 250 4.6 mm id, 5 m particle size C18 Waters Symmetry column. The mobile phase consisted of 0.02 M sodium dodecyl sulfate + 0.3 triethylamine + 10 n-propanol, prepared in 0.02 M orthophosphoric acid. The pH of the mobile phase was adjusted to pH 6.0, and it was pumped at a flow rate of 0.7 mL/min with UV detection at 262 nm. The method showed good linearity in the range of 280 g/mL, with an LOD of 0.40 g/mL (1.31 106 M) and an LOQ of 1.21 g/mL. The suggested method was successfully applied for the analysis of risedronate in raw material and a tablet formulation, with average recoveries of 99.91 1.30 and 101.52 0.30, respectively. The stability-indicating capability of the proposed method was proved using forced degradation. By changing the pH of the mobile phase to 4.0, the oxidative degradation product could be separated from risedronate.


1982 ◽  
Vol 65 (5) ◽  
pp. 1063-1065
Author(s):  
Stanley E Roberts

Abstract A high performance liquid chromatographic (HPLC) method is described for the quantitative determination of primidone in tablets. A ground tablet sample is diluted directly in the mobile phase, at a concentration of about 1 mg/mL of primidone, mixed and deaerated, and filtered. The resulting solution is then quantitated by HPLC. The average spike recoveries for the 50 mg and 250 mg tablets were 101.2% and 99.0%, respectively. The average recovery for an authentic mixture formulated at the 250 mg level was 100.1% with a relative standard deviation of 0.45%.


2017 ◽  
Vol 4 (1) ◽  
pp. 5-10 ◽  
Author(s):  
Ramesh Jayaprakash ◽  
Senthil Kumar Natesan

A simple, economic, accurate, sensitive, specific and precise stability indicating reverse phase high performance liquid chromatographic [RP-HPLC] method for the determination of Regorafenib in pure and tablet dosage from was developed and validated. The chromatographic separation was carried out using Phenomenex Luna-C18 column (4.5x250 mm; 5 µm particle size) as a stationary phase and methanol: acetonitrile: water (55:25:20 v/v/v) as a mobile phase. The flow rate of 1 mL/min was used with PDA detection at 275 nm. The retention time of Regorafenib was 2.480 min. RP-HPLC method was developed with linearity range of 40-240 µg/mL of Regorafenib. The correlation coefficient [r2] was found to be 0.9999. The assay results obtained was in good agreement with the corresponding labeled amount by developed method within range of 98.83 ± 0.6937. Accuracy of the method was confirmed by recovery studies and the recoveries were found to be between 99.61 % and 100.22 %, the corresponding %RSD was found to be 0.2029. Precision, LOD, LOQ, specificity, robustness and ruggedness were performed as per ICH Q2(R1) guidelines and were within the acceptance criteria. This method can be conveniently used to detect the possible degradation product in the dosage form of Regorafenib during stability studies (acidic, alkaline, oxidative, thermal and photolytic). The method proved to be effective on the analysis of stressed marketed tablet formulation.


2021 ◽  
Vol 37 (02) ◽  
pp. 493-498
Author(s):  
Mohan Bhatale ◽  
Neelakandan Kaliyaperumal ◽  
Gopalakrishnan Mannathusamy ◽  
Gurunathan Ramalingam

A simple, selective, linear having accuracy and specific of reverse phase high-performance liquid chromatographic (RP-HPLC) method for determination of Genotoxic impurity Hydroxylamine Hydrochloride of drug Leflunomide is reported.The separation and analysis were done on YMC Triart C18 (4.6 mm x 150 mm), having particle size 3.0 μm. KH2PO4 in 2000 mL of purified water and 2 mL triethylamine with pH 2.5 with phosphoric acid is mobile phase-A while acetonitrile is mobile Phase-B with gradient program. The elution achieved with 1.50 mL/min flow rate and using UV detection at 230 nm wavelength. Selected column oven temperature is 45°C and auto sampler 5°C respectively. In this method linearity and accuracy of Hydroxylamine HCl covered with specification limit of LOQ to 150 % (i.e.3 to 23 ppm). The observed correlation coefficient is 0.99965 and recovery in between 99.07 to 114.94. In method precision (ie.repeatability) and intermediate precision (IP) observed % RSD of six spiked test preparation is below 5.0 %. The standard and sample were stable for 3 days when stored at 2 to 8°C temperature. In robustness studies system suitability parameters ie tailing factor, theoretical plates and %RSD does not show significant changes. The present RP-HPLC method is selective, robust, linear, and precise for detection of Hydroxylamine HCl.


Author(s):  
Grishma H Patel ◽  
Shreya D Adeshra ◽  
Dhananjay B Meshram

A Novel, selective, accurate and rapid Reversed Phase High Performance Liquid Chromatographic (RPHPLC) method for the analysis of Efonidipine Hydrochloride Ethanolate and Telmisartan in binary mixture has been developed and validated. The chromatographic system consisted of a Phenomenex Kinetex ® 5µ C18 Size: 150 * 4.6mm column and the separation was achieved by using ambient temperature with a mobile phase containing mobile Phase Acetonitrile:25mM Phosphate Buffer pH 4.9 (45:55). The samples were monitored at 253 nm for detection at a flow rate of 1.0 mL/min and the retention time was about 7.77 and 4.10 mins for Efonidipine Hydrochloride Ehanolate and Telmisartan respectively. The calibration curve was linear over the concentration range 5-30 and 10-60 ?g/mL for Efonidipine Hydrochloride Ehanolate and Telmisartan respectively. The proposed method is accurate in the range of 99.75% - 100.10% recovery and precise (%RSD of intraday variation and % RSD of inter day variation were found to be within the acceptance criteria). Therefore, this method can be used as a more convenient and efficient option for the analysis of Efonidipine Hydrochloride Ehanolate and Telmisartan in Quality control laboratory.


2017 ◽  
Vol 1 (2) ◽  
pp. 1-8
Author(s):  
Milena Cristina Ribeiro Souza Magalhães ◽  
Alisson Samuel Portes Caldeira ◽  
Hanna De Sousa Rocha Almeida ◽  
Sílvia Ligório Fialho ◽  
Armando Da Silva Cunha Junior

A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of encapsulation efficiency of zidovudine in nanoparticules. The method was carried out in isocratic mode using 0.040M sodium acetate: methanol: acetonitrile: glacial acetic acid (880:100:20:2) as mobile phase, a C8 column at 25ºC and UV detection at 240 nm. The method was linear (r2 ˃ 0.99) over the range of 25.0-150.0 μg/mL, precise (RSD ˂ 5%), accurate (recovery = 100.5%), robust and selective. The validated HPLC-UV method can be successfully applied to determine the rate of zidovudine in nanoparticules.


Sign in / Sign up

Export Citation Format

Share Document