scholarly journals DISAIN SISTEM PENTANAHAN PROTEKSI PETIR SISTEM MULTIPLE VERTICAL ELECTRODES PADA TERMINAL LAWE-LAWE – PERTAMINA DHP

Sutet ◽  
2018 ◽  
Vol 7 (1) ◽  
pp. 48-53
Author(s):  
Redaksi Tim Jurnal

The purpose of Grounding system design is to ensure safety for personal and equipment, andto improve fault detection of protection system.All electrical equipment should be connected to the grounding system. A system ground refers tothe point in an electrical circuit that is connected to earth. This connection point is typically at theelectrical neutral.Grounding of electrical items must be performed inside the enclosure i.e. insulated copperconductor is going to be used for earthed loop.Grounding bar of equipment, cubicle, switchboard, dedicated inside terminal boxes, lightingfittings.Lightning protection, electrical and instrument equipment should be connected to the groundingsystem separately. The objectives of lightning protection are to avoid catastrophic equipment damage and to preventpersonal injury. The energy of a lightning stroke can readily ignite flammable vapors or damageequipment.Methode of calculation used of the groundingsystem design of lightning protection is multiple vertical electrodes system.

Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4118
Author(s):  
I Made Yulistya Negara ◽  
Daniar Fahmi ◽  
Dimas Anton Asfani ◽  
IGN Satriyadi Hernanda ◽  
Rendi Bagus Pratama ◽  
...  

In this study, the lightning protection system and grounding system of one plant of the petrochemical industry were investigated, evaluated, and improved. The methods used in this study were rolling sphere and angle protection methods. The grounding system of the building under study was modeled and simulated using ATP/EMTP (Alternative Transient Program/Electromagnetic Transient Program) software. The results show that the external lightning protection system of the prilling tower studied does not adhere to IEC 62305 and IEC 1024-1-1 standards. Moreover, the grounding configuration of the DCS building was not appropriate for protecting sensitive equipment inside. Lightning causes an enormous potential difference between lightning ground rods in the grounding system. Additionally, disabling the existing surge protective device (SPD) causes an increase in the magnitude of Ground Potential Rise at the DCS building. Improvement of the lightning protection system of the prilling tower and DCS building on Plant 1 of this petrochemical company as well as some other recommendations for improvements are proposed. This paper also shows evidence that external lightning protection, internal lightning protection, and the grounding system need to be connected to make an exemplary lightning protection system.


2020 ◽  
Vol 11 (7-2020) ◽  
pp. 66-72
Author(s):  
Liubov A. Belova ◽  

The earth-termination system for towers of ground-based wind turbines in addition to protective and functional grounding provides lightning protection grounding, which is especially important since the wind turbine is susceptible to lightning strikes. If insufficient protective measures are taken, the risk of damage to a wind turbine due to a lightning strike increases. Therefore, a well-thought-out built-in grounding system for wind turbine towers is needed, which would function as necessary and guarantee long-term mechanical strength and corrosion resistance. The configuration of grounding systems for wind turbines is discussed in IEC 61400-24, which deals with the topic of lightning protection for wind turbines, including detailed information on the choice of lightning protection measures and surge protection. It is advisable to create a lightning protection concept at the initial stage of planning a wind turbine in order to avoid later costly repairs and retrofitting.


Fire Safety ◽  
2021 ◽  
Vol 38 ◽  
pp. 24-31
Author(s):  
Yu. Rudyk ◽  
O. Nazarovets ◽  
I. Golovatchuk ◽  
N. Beznos

Introduction. Today requires the introduction and arrangement of modern enterprises automation of the technological process using various electronic and electrical equipment. The breakdown of one sensor leads to a stoppage of the technical process and thousands of losses. This equipment is sensitive to impulse overvoltages that occur for various reasons, as well as when hit by lightning. There is a misconception that the danger of lightning arises only when struck directly, forgetting about the socalled secondary phenomena, namely electromagnetic and electrostatic pulses. Pulse overvoltage is a short-term increase in voltage above the allowable value. Lightning protection systems are designed and designed to protect objects from dangerous lightning.Purpose. Given the automation of the process and the saturation of boilers with electronic and electrical equipment, there is a high risk of lightning and high potentials, which can lead to large-scale accidents. The purpose of this article is to validate the risk indicators for the boiler environment that occur during a thunderstorm.Methods. The use of various methods of calculation, assessment and ordering of risks during the design and layout of the system allows to implementation system lightning protection of buildings, equipment and people. General principles of risk assessment for the boiler environment must take into account: risk and determine the need for protection; the contribution of various risk components to the overall risk; the effect of various protection measures to reduce risk; selection of protection measures taking into account their economic efficiency.Results. Neglecting the high risk of a dangerous event leads to excessive damage and m irreparable losses, with which a person or community will not be able to achieve sustainable development. Therefore, it is a comprehensive, systematic approach to achieving safety, starting from the assessment stage, should take into account both the characteristics of the hazard, including a fire in the relevant facilities, and personal, the individual risk of death or injury. Lightning is an unpredictable natural event, no one in the world fully understands the mechanism of lightning and it is impossible to provide 100% protection under any circumstances under any standardization. For this purpose, the following calculations are given: loss of human life, including injuries; loss of the ability to provide public services; losses of cultural heritage and economic value of the building (structure) and economic losses required for the installation and operation of the system. Based on the obtained data, it is seen how the reduction of each risk is achieved depending on the proposed solution and the economic effect in general.Conclusion. Statistics on deaths and injuries from lightning hazards, losses from damage to property, buildings and struc-tures confirm that in risk assessment, which is standardized in DSTU EN 62305-2, it is necessary to introduce a methodology that would meet the conditions of Ukraine. The arrangement of the lightning protection system depends on the risk assessment, the reaction of the owner, the influence of control bodies. Therefore, it is important to decide on fire protection measures in lightning risk assessment procedures, but it can also be taken regardless of the results of the risk assessment where there is a desire to avoid unacceptable risk. Equipment that is often associated with two different services, e.g. power lines and data lines suffer a lot of surge damage. This case is not covered by the RX risk component. However, appropriate protection measures can be selected and established (see IEC 62305-4).


2017 ◽  
Vol 50 (1) ◽  
pp. 3648-3653 ◽  
Author(s):  
M. Krueger ◽  
T. Koenings ◽  
Y. Liu ◽  
S.X. Ding ◽  
J. Saijai ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document