scholarly journals Towards Higher Sensitivity of Mass Spectrometry: A Perspective From the Mass Analyzers

2021 ◽  
Vol 9 ◽  
Author(s):  
Chang Li ◽  
Shiying Chu ◽  
Siyuan Tan ◽  
Xinchi Yin ◽  
You Jiang ◽  
...  

Mass spectrometry (MS) is one of the most widely used analytical techniques in many fields. Recent developments in chemical and biological researches have drawn much attention to the measurement of substances with low abundances in samples. Continuous efforts have been made consequently to further improve the sensitivity of MS. Modifications on the mass analyzers of mass spectrometers offer a direct, universal and practical way to obtain higher sensitivity. This review provides a comprehensive overview of the latest developments in mass analyzers for the improvement of mass spectrometers’ sensitivity, including quadrupole, ion trap, time-of-flight (TOF) and Fourier transform ion cyclotron (FT-ICR), as well as different combinations of these mass analyzers. The advantages and limitations of different mass analyzers and their combinations are compared and discussed. This review provides guidance to the selection of suitable mass spectrometers in chemical and biological analytical applications. It is also beneficial to the development of novel mass spectrometers.

2021 ◽  
Vol 217 (1) ◽  
Author(s):  
J. Simcic ◽  
D. Nikolić ◽  
A. Belousov ◽  
D. Atkinson ◽  
C. Lee ◽  
...  

AbstractTo date, a variety of different types of mass spectrometers have been utilized on missions to study the composition of atmospheres of solar system bodies, including Venus, Mars, Jupiter, Titan, the moon, and several comets. With the increasing interest in future small probe missions, mass spectrometers need to become even more versatile, lightweight, compact, and sensitive.For in situ exploration of ice giant atmospheres, the highest priority composition measurements are helium and the other noble gases, noble gas isotopes, including 3He/4He, and other key isotopes like D/H. Other important but lower priority composition measurements include abundances of volatiles C, N, S, and P; isotopes 13C/12C, 15N/14N, 18O/17O/16O; and disequilibrium species PH3, CO, AsH3, GeH4, and SiH4. Required measurement accuracies are largely defined by the accuracies achieved by the Galileo (Jupiter) probe Neutral Mass Spectrometer and Helium Abundance Detectors, and current measurement accuracies of solar abundances.An inherent challenge of planetary entry probe mass spectrometers is the introduction of material to be sampled (gas, solid, or liquid) into the instrument interior, which operates at a vacuum level. Atmospheric entry probe mass spectrometers typically require a specially designed sample inlet system, which ideally provides highly choked, nearly constant mass-flow intake over a large range of ambient pressures. An ice giant descent probe would have to operate for 1-2 hours over a range of atmospheric pressures, possibly covering 2 or more orders of magnitude, from the tropopause near 100 mbar to at least 10 bars, in an atmospheric layer of depth beneath the tropopause of about 120 km at Neptune and about 150 km at Uranus.The Jet Propulsion Laboratory’s Quadrupole Ion Trap Mass Spectrometer (QITMS) is being developed to achieve all of these requirements. A compact, wireless instrument with a mass of only 7.5 kg, and a volume of 7 liters (7U), the JPL QITMS is currently the smallest flight mass spectrometer available for possible use on planetary descent probes as well as small bodies, including comet landers and surface sample return missions. The QITMS is capable of making measurements of all required constituents in the mass range of 1–600 atomic mass units (u) at a typical speed of 50 mass spectra per second, with a sensitivity of up to $10^{13}$ 10 13  counts/mbar/sec and mass resolution of $m/\Delta m=18000$ m / Δ m = 18000 at m/q = 40. (Throughout this paper we use the unit of m/q = u/e for the mass-to-charge ratio, where atomic mass unit and elementary charge are $1~\text{u} = 1.66\times 10^{-27}~\text{kg}$ 1 u = 1.66 × 10 − 27 kg and $1\text{e} = 1.6\times 10^{-19}$ 1 e = 1.6 × 10 − 19 C, respectively.) The QITMS features a novel MEMS-based inlet system driven by a piezoelectric actuator that continuously regulates gas flow at inlet pressures of up to 100 bar.In this paper, we present an overview of the QITMS capabilities, including instrument design and characteristics of the inlet system, as well as the most recent results from laboratory measurements in different modes of operation, especially suitable for ice giant atmospheres exploration.


2021 ◽  
Author(s):  
Grzegorz Skrzypek ◽  
Philip Dunn

<p>The stable HCNOS isotope compositions can be reported in various ways depending on scientific domain and needs. The most common notations are 1) the isotope ratio of two stable isotopes; 2) isotope delta value, and 3) atom fraction of one or more of the isotopes. Frequently recalculations between these notations are required for certain applications, particularly when merging different data sets. All these recalculations require using the absolute isotope ratio for the zero points of the stable isotope delta scales (<em>R<sub>std</sub></em>). However, several <em>R<sub>std</sub></em> with very contrasting values have been proposed over time and there is no common agreement on which values should be used word-wide (Skrzypek and Dunn, 2020a).</p><p>Differences in the selection of <em>R<sub>std</sub></em>value may lead to significant differences between different data sets recalculated from delta value to other notations. These differences in R<sub>std</sub> have a significant influence also on the normalization of raw values but only when the normalization is conducted versus the working standard gas value. We proposed a user-friendly EasyIsoCalculator (http://easyisocalculator.gskrzypek.com) that allows recalculation between the main expressions of isotope compositions using various <em>R<sub>std</sub></em> and aids for identification of potential inconsistencies in recalculations (Skrzypek and Dunn, 2020b).</p><p> </p><p>Skrzypek G., Dunn P. 2020a. Absolute isotope ratios defining isotope scales used in isotope ratio mass spectrometers and optical isotope instruments. Rapid Communications in Mass Spectrometry 34: e8890.</p><p>Skrzypek G., Dunn P., 2020b. The recalculation of the stable isotope expressions for HCNOS – EasyIsoCalculator. Rapid Communications in Mass Spectrometry 34: e8892.</p>


Sign in / Sign up

Export Citation Format

Share Document