scholarly journals High-Frequency Ultrasonography and Evaporimetry in Non-invasive Evaluation of the Nail Unit

2021 ◽  
Vol 8 ◽  
Author(s):  
Marta Szymoniak-Lipska ◽  
Adriana Polańska ◽  
Dorota Jenerowicz ◽  
Adam Lipski ◽  
Ryszard Żaba ◽  
...  

Background: The nail unit (NU) is a complex structure that performs a number of functions, including protection, defense, manipulation, and palpation. Non-invasive research methods can facilitate the recognition of NU structure and function. Evaporimetry and HF-USG due to their availability of equipment and low research costs seem to be particularly noteworthy, but so far have been assessed to a limited extent. The aim of the presented study was to check the usefulness of TOWL and HF-USG in examination of NU.Materials and Methods: A total of 58 volunteers aged 25–65 years (mean age: 41 ± 10.16 years) were qualified for the study. The subjects did not present symptoms of clinically evident onychopathy and did not suffer from any dermatoses associated with lesions occurring within the NU. Additionally, the patients did not suffer from systemic diseases that could affect NU (including heart, lung, and endocrine diseases). In all volunteers, the measurement of TOWL and 20 MHz ultrasonography [high-frequency ultrasonography (HF-USG)] with the special emphasis on determination of nail plate thickness were performed.Results: Analysis of 464 HF-USG images revealed that the nail plate presented as two hyperechoic, parallel streaks (railway sign) with a linear hypoechoic middle layer between them. Matrix was visualized as a hypoechoic structure with blurred boundaries, mostly within the fourth and fifth fingers and more often in women. We found statistically significant correlations between the type of a finger and the thickness of the nail plate both in the entire study group and taking into account gender. In the dominant hand, the results were r = −0.341; p < 0.001; r = −0.417, p < 0.001; and r = 0.337; p = 0.001 (for the whole group, for women, and for men, respectively). In the non-dominant hand, the results were r = −0.465; p < 0.001; r = −0.493, p < 0.01; and r = −0.503; p < 0.01 (for the whole group, for women, and for men, respectively). There were statistically significant differences in the thickness of the nail plates of the corresponding types of fingers between female and male NUs. Statistically significant correlations were found between the type of a finger and the TOWL value in the whole group and taking into account gender (p < 0.05), except for the non-dominant hand in men. There were no statistically significant differences in the TOWL values of the corresponding types of fingers between male and female NUs (p > 0.05). There was no statistically significant correlation between the TOWL value and the nail plate thickness in any of the tested NUs, apart from the one statistically significant correlation in nd5 (r = 0.390, p = 0.021).Conclusions: To sum up, non-invasive methods, such as HF-USG and TOWL, enable assessment of the NU and are useful in examination of its structure and function. HF-USG shows characteristic elements of NUs that can be distinguished because of differences in their echogenicity. The thickness of the nail plate and TOWL depend on the type of finger, and show a relationship with gender.

2016 ◽  
Vol 4 (48) ◽  
pp. 7793-7812 ◽  
Author(s):  
Kewen Lei ◽  
Qian Ma ◽  
Lin Yu ◽  
Jiandong Ding

In vivo imaging of biomedical hydrogels enables real-time and non-invasive visualization of the status of structure and function of hydrogels.


2021 ◽  
pp. 028418512110529
Author(s):  
Tiezheng Wang ◽  
Hengtao Qi ◽  
Dehua Wang ◽  
Zengtao Wang ◽  
Shougang Bao ◽  
...  

Background In the past, the diagnosis of hourglass-like fascicular constriction(s) of the anterior interosseous nerve mostly depended on electrophysiological examination, by which the location could not be diagnosed. There are few studies on the evaluation of hourglass-like fascicular constriction(s) by ultrasonography. Purpose To evaluate the role of ultrasonography in the diagnosis of hourglass-like fascicular constriction(s) of the anterior interosseous nerve. Material and Methods A retrospective analysis of 12 patients with hourglass-like fascicular constriction(s) of the anterior interosseous nerve was carried out, and the characteristics of the high-frequency ultrasonographic images were summarized and compared with surgical exploration. Results The 12 cases of hourglass-like fascicular constriction(s) of the anterior interosseous nerve were all located in the median nerve of the distal upper arm, including nine cases of single hourglass-like fascicular constriction and three cases of multiple hourglass-like fascicular constrictions. High-frequency ultrasonography can accurately locate the hourglass-like fascicular constriction(s) of the anterior interosseous nerve and the extent of neuropathy. The ultrasonographic images of hourglass-like fascicular constriction(s) of the anterior interosseous nerve showed single or multiple hourglass-like change(s) in the median nerve of the distal upper arm. The nerve fascicles on both sides of the affected nerve with hourglass-like change thickened. Conclusions High-frequency ultrasonography could be a reliable, convenient, and non-invasive diagnostic imaging method for hourglass-like fascicular constriction(s) of the anterior interosseous nerve.


2015 ◽  
Vol 243 (2) ◽  
pp. 462-465 ◽  
Author(s):  
Patrick G. McPhee ◽  
Jan Willem Gorter ◽  
Lisa M. Cotie ◽  
Brian W. Timmons ◽  
Todd Bentley ◽  
...  

BMC Urology ◽  
2015 ◽  
Vol 15 (1) ◽  
Author(s):  
David Burmeister ◽  
Bimjhana Bishwokarma ◽  
Tamer AbouShwareb ◽  
John Olson ◽  
Maja Herco ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document