scholarly journals Handclap for Acoustic Measurements: Optimal Application and Limitations

Acoustics ◽  
2020 ◽  
Vol 2 (2) ◽  
pp. 224-245 ◽  
Author(s):  
Nikolaos M. Papadakis ◽  
Georgios E. Stavroulakis

Handclap is a convenient and useful acoustic source. This study aimed to explore its optimal application and limitations for acoustic measurements as well for other possible utilizations. For this purpose, the following steps were performed: investigation of the optimal hand configuration for acoustic measurements and measurements at different microphone source distances and at different spaces and positions. All measurements were performed with a handclap and a dodecahedron speaker for comparison. The results indicate that the optimal hand configuration (among 11) is with the hands cupped and held at an angle due to the superior low frequency spectrum. This configuration produced usable acoustic parameter measurements in the low frequency range in common room background levels unlike other configurations. The reverberation time was measured across different spaces and positions with a deviation less than three and just a noticeable difference of the signal-to-noise ratio within or near the ISO 3382-1 limits for each corresponding octave band. Other acoustic parameters (i.e., early decay time, clarity) were measured with greater deviations for reasons discussed in the text. Finally, practical steps for measurements with a handclap as an acoustic source are suggested.

1997 ◽  
Vol 500 ◽  
Author(s):  
Š. Lányi ◽  
M. Hruškovic

ABSTRACTThe operation principle and main properties of a Scanning Capacitance Microscope (SCM) are described. It is called low-frequency, because in its design typical low-frequency techniques are utilised. The main attention is focused on its lateral resolution, signal-to-noise ratio and the possibility to detect dielectric losses.Mapping the electrostatic field of a shielded microscope probe was used to calculate the stray capacitance, flux density, sensitivity and contrast obtained on a flat conducting surface, as well as on a surface covered by a thin dielectric film. The effect of dielectric losses, represented by a parallel conductance, on the detected capacitance and the resulting phase shift has been derived.Using the results of mapping, the requirements on a SCM input stage and the possible solutions are discussed. From the point of view of frequency range and noise the best is an electrometric input stage, with input impedance represented by its capacitance.The achieved signal-to-noise ratio of the low frequency Scanning Capacitance Microscope renders the extension of the working frequency range to lower frequencies. The input stage can be optimised for a frequency range from about 1 kHz to a few MHz, with the possibility to extend it to about 10 MHz at the cost of reduced sensitivity at the lowest frequencies.


Acoustics ◽  
2020 ◽  
Vol 2 (4) ◽  
pp. 803-811
Author(s):  
Rick de Vos ◽  
Nikolaos M. Papadakis ◽  
Georgios E. Stavroulakis

A handclap is a convenient and easily available source for room acoustic measurements. If used correctly (e.g., application of optimal hand configuration) it can provide usable results for the measurement of acoustic parameters, within an expected deviation. Its biggest drawbacks are the low sound pressure level (especially in the low frequency range) as well as its low repeatability. With this in mind, this paper explores the idea of testing a handclap with a glove in order to assess the effect on its source characteristics. For this purpose, measurements were performed with 12 participants wearing leather gloves. Sound levels were compared with simple handclaps without gloves, and between grouped results (overall A-weighted SPL, octave bands, 1/3 octave bands). Measurements were also performed several times to evaluate the effect on repeatability. Results indicate that the use of leather gloves can increase the sound levels of a handclap by 10 dB and 15 dB in the low frequency ranges (63 Hz and 125 Hz octave bands, respectively). Handclaps with leather gloves also point toward improved repeatability, particularly in the low-frequency part of the frequency spectrum. In conclusion, compared to simple handclaps without gloves, evidence from this study supports the concept that handclaps with leather gloves can be used in engineering practices for improved room acoustic measurements of room impulse response.


Geophysics ◽  
2021 ◽  
pp. 1-54
Author(s):  
Milad Bader ◽  
Robert G. Clapp ◽  
Biondo Biondi

Low-frequency data below 5 Hz are essential to the convergence of full-waveform inversion towards a useful solution. They help build the velocity model low wavenumbers and reduce the risk of cycle-skipping. In marine environments, low-frequency data are characterized by a low signal-to-noise ratio and can lead to erroneous models when inverted, especially if the noise contains coherent components. Often field data are high-pass filtered before any processing step, sacrificing weak but essential signal for full-waveform inversion. We propose to denoise the low-frequency data using prediction-error filters that we estimate from a high-frequency component with a high signal-to-noise ratio. The constructed filter captures the multi-dimensional spectrum of the high-frequency signal. We expand the filter's axes in the time-space domain to compress its spectrum towards the low frequencies and wavenumbers. The expanded filter becomes a predictor of the target low-frequency signal, and we incorporate it in a minimization scheme to attenuate noise. To account for data non-stationarity while retaining the simplicity of stationary filters, we divide the data into non-overlapping patches and linearly interpolate stationary filters at each data sample. We apply our method to synthetic stationary and non-stationary data, and we show it improves the full-waveform inversion results initialized at 2.5 Hz using the Marmousi model. We also demonstrate that the denoising attenuates non-stationary shear energy recorded by the vertical component of ocean-bottom nodes.


2012 ◽  
Vol 108 (10) ◽  
pp. 2837-2845 ◽  
Author(s):  
Go Ashida ◽  
Kazuo Funabiki ◽  
Paula T. Kuokkanen ◽  
Richard Kempter ◽  
Catherine E. Carr

Owls use interaural time differences (ITDs) to locate a sound source. They compute ITD in a specialized neural circuit that consists of axonal delay lines from the cochlear nucleus magnocellularis (NM) and coincidence detectors in the nucleus laminaris (NL). Recent physiological recordings have shown that tonal stimuli induce oscillatory membrane potentials in NL neurons (Funabiki K, Ashida G, Konishi M. J Neurosci 31: 15245–15256, 2011). The amplitude of these oscillations varies with ITD and is strongly correlated to the firing rate. The oscillation, termed the sound analog potential, has the same frequency as the stimulus tone and is presumed to originate from phase-locked synaptic inputs from NM fibers. To investigate how these oscillatory membrane potentials are generated, we applied recently developed signal-to-noise ratio (SNR) analysis techniques (Kuokkanen PT, Wagner H, Ashida G, Carr CE, Kempter R. J Neurophysiol 104: 2274–2290, 2010) to the intracellular waveforms obtained in vivo. Our theoretical prediction of the band-limited SNRs agreed with experimental data for mid- to high-frequency (>2 kHz) NL neurons. For low-frequency (≤2 kHz) NL neurons, however, measured SNRs were lower than theoretical predictions. These results suggest that the number of independent NM fibers converging onto each NL neuron and/or the population-averaged degree of phase-locking of the NM fibers could be significantly smaller in the low-frequency NL region than estimated for higher best-frequency NL.


2018 ◽  
Author(s):  
Meyer Gabriel ◽  
Caponcy Julien ◽  
Paul A. Salin ◽  
Comte Jean-Christophe

AbstractLocal field potential (LFP) recording is a very useful electrophysiological method to study brain processes. However, this method is criticized for recording low frequency activity in a large area of extracellular space potentially contaminated by distal activity. Here, we theoretically and experimentally compare ground-referenced (RR) with differential recordings (DR). We analyze electrical activity in the rat cortex with these two methods. Compared with RR, DR reveals the importance of local phasic oscillatory activities and their coherence between cortical areas. Finally, we show that DR provides a more faithful assessment of functional connectivity caused by an increase in the signal to noise ratio, and of the delay in the propagation of information between two cortical structures.


2016 ◽  
Vol 7 (3) ◽  
pp. 1-9 ◽  
Author(s):  
Sahar A. El-Rahman Ismail ◽  
Dalal Al Makhdhub ◽  
Amal A. Al Qahtani ◽  
Ghadah A. Al Shabanat ◽  
Nouf M. Omair ◽  
...  

We live in an information era where sensitive information extracted from data mining systems is vulnerable to exploitation. Privacy preserving data mining aims to prevent the discovery of sensitive information. Information hiding systems provide excellent privacy and confidentiality, where securing confidential communications in public channels can be achieved using steganography. A cover media are exploited using steganography techniques where they hide the payload's existence within appropriate multimedia carriers. This paper aims to study steganography techniques in spatial and frequency domains, and then analyzes the performance of Discrete Cosine Transform (DCT) based steganography using the low frequency and the middle frequency to compare their performance using Peak Signal to Noise Ratio (PSNR) and Mean Square Error (MSE). The experimental results show that middle frequency has the larger message capacity and best performance.


Sensors ◽  
2020 ◽  
Vol 20 (19) ◽  
pp. 5704
Author(s):  
Zhenhu Jin ◽  
Yupeng Wang ◽  
Kosuke Fujiwara ◽  
Mikihiko Oogane ◽  
Yasuo Ando

Thanks to their high magnetoresistance and integration capability, magnetic tunnel junction-based magnetoresistive sensors are widely utilized to detect weak, low-frequency magnetic fields in a variety of applications. The low detectivity of MTJs is necessary to obtain a high signal-to-noise ratio when detecting small variations in magnetic fields. We fabricated serial MTJ-based sensors with various junction area and free-layer electrode aspect ratios. Our investigation showed that their sensitivity and noise power are affected by the MTJ geometry due to the variation in the magnetic shape anisotropy. Their MR curves demonstrated a decrease in sensitivity with an increase in the aspect ratio of the free-layer electrode, and their noise properties showed that MTJs with larger junction areas exhibit lower noise spectral density in the low-frequency region. All of the sensors were able detect a small AC magnetic field (Hrms = 0.3 Oe at 23 Hz). Among the MTJ sensors we examined, the sensor with a square-free layer and large junction area exhibited a high signal-to-noise ratio (4792 ± 646). These results suggest that MTJ geometrical characteristics play a critical role in enhancing the detectivity of MTJ-based sensors.


Sign in / Sign up

Export Citation Format

Share Document