scholarly journals Precast Bridges of Bamboo Reinforced Concrete in Disadvantaged Village Areas in Indonesia

2020 ◽  
Vol 10 (20) ◽  
pp. 7158
Author(s):  
Muhtar

Bamboo is an inexpensive, environmentally friendly, and renewable building material that thrives in Indonesia. Bamboo has a high tensile strength but also has weaknesses, namely, it is easily attacked by insects and has high water absorption. Utilization of bamboo as a precast concrete bridge reinforcement must be treated first through soaking, drying, and giving a waterproof coating and sand. This research aimed to obtain a precast bamboo reinforced concrete bridge technology with good integrity, with measuring parameters of deformation and deflection according to AASHTO standards. The dimensions of the bridge were a span of 320 cm, a width of 224 cm, and a height of 115 cm. Two bridge frames were connected by four bridge beams. The bridge plate was made of a 10-cm-thick concrete plate. The bridge support of the reinforced concrete is assumed to be the hinge support and the rubber bearing is assumed to be the roller support. The bamboo reinforced concrete frame bridge test was carried out directly with a load of a minibus-type vehicle. The test results show that the precast bamboo reinforced concrete frame bridges have sufficiently good integrity; that is, they can distribute loads with deflection and deformation that do not exceed their permits. The maximum displacement occurs in the bridge frame of 0.25 mm, meeting the requirements based on the AASTHO and RSNI T-12-2004 standards, which is not more than Δmax = L/800 = 3.75 mm. The maximum deformation occurs in the bridge beam of 0.20 mm, and the bridge frame of 0.13 mm meets the requirements based on the AASTHO and RSNI T-12-2004 standards, which is not more than δmax = L/800 = 3.75 mm.

Author(s):  
Sergiu-Gheorghe Țere ◽  
Bogdan Hegheș ◽  
Horea Constantinescu

It is well-known that for single-storey steel structures, the framework is greatly strengthened and stiffened following the attachment of the roof, floors and walls. The panels in the roofing, flooring and side cladding are also known as “shear diaphragms” by virtue of their resistance to being deformed into parallelograms. This has been verified by on-site practical experience of many structures and design provisions are available for structural engineers. Despite the fact that for single-storey structures, the corrugated steel sheets are the standard elements in constructing the envelopes, in what concerns the reinforced concrete frames there are no guidelines nor recommendations on how to consider the diaphragm effect in structural analysis. In order to better understand the interaction between the corrugated steel sheets and the reinforced concrete frame, a real precast reinforced concrete frame structure was built for experimental testing. The aim of the experimental test is to study the diaphragm effect for reinforced concrete structures and based on the results to identify the discrepancies identified compared to steel structures. The investigation attempts to provide a starting point for future research on the stressed skin design acting on reinforced concrete frames. At the end of the article conclusions are drawn based on the experience obtained during the experimental test.


2020 ◽  
Vol 12 (24) ◽  
pp. 10360
Author(s):  
Hyun-Do Yun ◽  
Sun-Woong Kim ◽  
Wan-Shin Park ◽  
Sun-Woo Kim

The purpose of this study was to experimentally evaluate the effect of a hinged steel damping system on the shear behavior of a nonductile reinforced concrete frame with an opening. For the experimental test, a total of three full-scale reinforced concrete frame specimens were planned, based on the “no retrofitting” (NR) specimens with non-seismic details. The main research questions were whether the hinged steel damping system is reinforced and whether torsion springs are installed in the hinged steel damping system. From the results of the experiment, the hinged steel damping system (DR specimen) was found to be effective in seismic retrofitting, while isolating the opening of the reinforced concrete (RC) frame, and the torsion spring installed at the hinged connection (DSR specimen) was evaluated to be effective in controlling the amount of deformation of the upper and lower dampers. The strength, stiffness, and energy dissipation capacity of the DSR specimen were slightly improved compared to the DR specimen, and it was confirmed that stress redistribution was induced by the rotational stiffness of the torsion spring installed in the hinge connection between the upper and lower frames.


2003 ◽  
Vol 6 (1) ◽  
pp. 15-21 ◽  
Author(s):  
Sayed A. Attaalla ◽  
Mehran Agbabian

The characteristics of the shear deformation inside the beam-column joint core of reinforced concrete frame structures subjected to seismic loading are discussed in this paper. The paper presents the formulation of an analytical model based on experimental observations. The model is intended to predict the expansions of beam-column joint core in the horizontal and vertical directions. The model describes the strain compatibility inside the joint in an average sense. Its predictions are verified utilizing experimental measurements obtained from tests conducted on beam-column connections. The model is found to adequately predict the components of shear deformation in the joint core and satisfactorily estimates the average strains in the joint hoops up to bond failure. The model may be considered as a simple, yet, important step towards analytical understanding of the sophisticated shear mechanism inside the joint and may be implemented in a controlled-deformation design technique of the joint.


2016 ◽  
Vol 711 ◽  
pp. 982-988
Author(s):  
Alex Brodsky ◽  
David Z. Yankelevsky

Numerous studies have been conducted on the in plane behavior of masonry infill walls to lateral loading simulating earthquake action on buildings. The present study is focused on a problem that has almost not been studied regarding the vertical (opposed to lateral) in-plane action on these walls. This may be of concern when a supporting column of a multi-storey reinforced concrete frame with infill masonry walls undergoes a severe damage due to an extreme loading such as a strong earthquake, car impact or military or terror action in proximity to the column. The loss of the supporting column may cause a fully or partly progressive collapse to a bare reinforced concrete frame, without infill masonry walls. The presence of the infill masonry walls may restrain the process and prevent the development of a progressive collapse. The aim of the present study is to test the in-plane composite action of Reinforced Concrete (RC) frames with infill masonry walls under vertical loading through laboratory experiments and evaluate the contributions of infill masonry walls, in an attempt to examine the infill masonry wall added resistance to the bare frame under these circumstances. Preliminary results of laboratory tests that have been conducted on reinforced concrete infilled frames without a support at their end, under monotonic vertical loading along that column axis will be presented. The observed damages and failure modes under vertical loading are clearly different from the already known failure modes observed in the case of lateral loading.


1970 ◽  
Vol 96 (6) ◽  
pp. 1246-1250
Author(s):  
James C. Anderson ◽  
Vitelmo V. Bertero ◽  
O. A. Glogau

1983 ◽  
Vol 73 (5) ◽  
pp. 1435-1450
Author(s):  
Andrzej S. Nowak ◽  
Elizabeth L. M. Rose

Abstract This paper deals with the evaluation of seismic risk for commercial buildings in Memphis, Tennessee. The seismicity of the area is summarized, and commercial buildings are divided into categories with regard to parameters such as number of stories, year of construction, assessed value, total floor area, and structural type. The distributions of these parameters are presented in the figures. During the study, over 15 buildings were examined on site by a team of experts to evaluate their seismic resistances. The quality of the design, materials, and construction was found to be surprisingly good, particularly in those structures built since 1900. Seismic resistance is analytically evaluated for five buildings: a four-story reinforced concrete frame; a four-story steel structure with vertical trusses; a 13-story stell frame; and two multi-story reinforced concrete frames. The loadings from four sources are considered: EI Centro and Taft earthquakes in California (1940 and 1952, respectively) and the forces specified in the 1979 UBC and 1981 BOCA codes. Ratios of load to capacity are calculated. For each building considered, the expected percentage of damage is evaluated for the two earthquakes. The damage prediction is extended to all commercial buildings in Memphis.