scholarly journals Internal Mechanics of a Subject-Specific Wrist in the Sagittal Versus Dart-Throwing Motion Plane in Adult and Elder Models: Finite Element Analyses

2021 ◽  
Vol 11 (11) ◽  
pp. 5275
Author(s):  
Vered Mahpari ◽  
Yafa Levanon ◽  
Yael Kaufman-Cohen ◽  
Meital Zilberman ◽  
Sigal Portnoy

Introduction: Most of the wrist motions occur in a diagonal plane of motion, termed the dart-throwing motion (DTM) plane; it is thought to be more stable compared with movement in the sagittal plane. However, the effect of the altered carpus motion during DTM on the stress distribution at the radiocarpal joint has yet to be explored. Aim: To calculate and compare the stresses between the radius and two carpal bones (the scaphoid and the lunate) in two wrist positions, extension and radial extension (position in DTM), and between an adult and an elder model. Methods: A healthy wrist of a 40-year-old female was scanned using Magnetic Resonance Imaging in two wrist positions (extension, radial extension). The scans were transformed into three-dimensional models and meshed. Finite element (FE) analyses in each position of the wrist were conducted for both adult and elder models, which were differentiated by the mechanical properties of the ligaments. The distal surfaces of the carpal bones articulating with the metacarpals were loaded by physically accurate tendon forces for each wrist position. Results: The von Mises, shear stresses and contact stresses were higher in the extension model compared with the radial-extension model and were higher for the radius-scaphoid interface in the adult model compared with the elder model. In the radius-scaphoid interface, the stress differences between the two wrist positions were smaller in the elder model (11.5% to 22.5%) compared with the adult model (33.6–41.5%). During radial extension, the contact area at the radius-lunate interface was increased, more so in the adult model (222.2%) compared with the elder model (127.9%), while the contact area at the radius-scaphoid was not affected by the position of the wrist in the adult model (100.9%) but decreased in the elder model (50.2%) during radial extension. Conclusion: The reduced stresses during radial extension might provide an explanation to our frequent use of this movement pattern, as the reduced stresses decrease the risk of overuse injury. Our results suggest that this conclusion is relevant to both adults and elder individuals.

1998 ◽  
Vol 120 (2) ◽  
pp. 273-280 ◽  
Author(s):  
W. Z. Kong ◽  
V. K. Goel ◽  
L. G. Gilbertson

A combined approach involving optimization and the finite element technique was used to predict biomechanical parameters in the lumbar spine during static lifting in the sagittal plane. Forces in muscle fascicles of the lumbar region were first predicted using an optimization-based force model including the entire lumbar spine. These muscle forces as well as the distributed upper body weight and the lifted load were then applied to a three-dimensional finite element model of the thoracolumbar spine and rib cage to predict deformation, the intradiskal pressure, strains, stresses, and load transfer paths in the spine. The predicted intradiskal pressures in the L3-4 disk at the most deviated from the in vivo measurements by 8.2 percent for the four lifting cases analyzed. The lumbosacral joint flexed, while the other lumbar joints extended for all of the four lifting cases studied (rotation of a joint is the relative rotation between its two vertebral bodies). High stresses were predicted in the posterolateral regions of the endplates and at the junctions of the pedicles and vertebral bodies. High interlaminar shear stresses were found in the posterolateral regions of the lumbar disks. While the facet joints of the upper two lumbar segments did not transmit any load, the facet joints of the lower two lumbar segments experienced significant loads. The ligaments of all lumbar motion segments except the lumbosacral junction provided only marginal moments. The limitations of the current model and possible improvements are discussed.


1992 ◽  
Vol 20 (2) ◽  
pp. 83-105 ◽  
Author(s):  
J. P. Jeusette ◽  
M. Theves

Abstract During vehicle braking and cornering, the tire's footprint region may see high normal contact pressures and in-plane shear stresses. The corresponding resultant forces and moments are transferred to the wheel. The optimal design of the tire bead area and the wheel requires a detailed knowledge of the contact pressure and shear stress distributions at the tire/rim interface. In this study, the forces and moments obtained from the simulation of a vehicle in stationary braking/cornering conditions are applied to a quasi-static braking/cornering tire finite element model. Detailed contact pressure and shear stress distributions at the tire/rim interface are computed for heavy braking and cornering maneuvers.


1985 ◽  
Vol 52 (4) ◽  
pp. 801-805 ◽  
Author(s):  
P. R. Heyliger ◽  
J. N. Reddy

A quasi-three dimensional elasticity formulation and associated finite element model for the stress analysis of symmetric laminates with free-edge cap reinforcement are described. Numerical results are presented to show the effect of the reinforcement on the reduction of free-edge stresses. It is observed that the interlaminar normal stresses are reduced considerably more than the interlaminar shear stresses due to the free-edge reinforcement.


2016 ◽  
Vol 41 (5) ◽  
pp. E149-E158 ◽  
Author(s):  
VF Wandscher ◽  
CD Bergoli ◽  
IF Limberger ◽  
TP Cenci ◽  
P Baldissara ◽  
...  

SUMMARY Objective: This article aims to present a fractographic analysis of an anterior tooth restored with a glass fiber post with parallel fiber arrangement, taking into account force vectors, finite element analysis, and scanning electron microscopy (SEM). Methods: A patient presented at the Faculty of Dentistry (Federal University of Santa Maria, Brazil) with an endodontically treated tooth (ETT), a lateral incisor that had a restorable fracture. The treatment was performed, and the fractured piece was analyzed using stereomicroscopy, SEM, and finite element analysis. Results: The absence of remaining coronal tooth structure might have been the main factor for the clinical failure. We observed different stresses actuating in an ETT restored with a fiber post as well as their relationship with the ultimate fracture. Tensile, compression, and shear stresses presented at different levels inside the restored tooth. Tensile and compressive stresses acted together and were at a maximum in the outer portions and a minimum in the inner portions. In contrast, shear stresses acted concomitantly with tensile and compressive stresses. Shear was higher in the inner portions (center of the post), and lower in the outer portions. This was confirmed by finite element analysis. The SEM analysis showed tensile and compression areas in the fiber post (exposed fibers=tensile areas=lingual surface; nonexposed fibers=compression areas=buccal surface) and shear areas inside the post (scallops and hackle lines). Stereomicroscopic analysis showed brown stains in the crown/root interface, indicating the presence of microleakage (tensile area=lingual surface). Conclusion: We concluded that glass fiber posts with parallel fibers (0°), when restoring anterior teeth, present a greater fracture potential by shear stress because parallel fibers are not mechanically resistant to support oblique occlusal loads. Factors such as the presence of remaining coronal tooth structure and occlusal stability assist in the biomechanical equilibrium of stresses that act upon anterior teeth.


Author(s):  
R E Cornwell

There are numerous situations in machine component design in which curved beams with cross-sections of arbitrary geometry are loaded in the plane of curvature, i.e. in flexure. However, there is little guidance in the technical literature concerning how the shear stresses resulting from out-of-plane loading of these same components are effected by the component's curvature. The current literature on out-of-plane loading of curved members relates almost exclusively to the circular and rectangular cross-sections used in springs. This article extends the range of applicability of stress concentration factors for curved beams with circular and rectangular cross-sections and greatly expands the types of cross-sections for which stress concentration factors are available. Wahl's stress concentration factor for circular cross-sections, usually assumed only valid for spring indices above 3.0, is shown to be applicable for spring indices as low as 1.2. The theory applicable to the torsion of curved beams and its finite-element implementation are outlined. Results developed using the finite-element implementation agree with previously available data for circular and rectangular cross-sections while providing stress concentration factors for a wider variety of cross-section geometries and spring indices.


2011 ◽  
Vol 110-116 ◽  
pp. 1458-1465 ◽  
Author(s):  
M. Khadem ◽  
M. M. Kheirikhah

Nowadays Shape Memory Alloys (SMAs) are used as actuators in many applications such as aerospace structures. In sandwich structures, the SMA wires or plates are used in the skins for shape control of the structure or vibration damping. In this paper, bending behavior of sandwich plates with embedded SMA wires in their skins is studied. 3D finite element method is used for construction and analysis of the sandwich plate with a flexible core and two stiff skins. Some important points such as continuity conditions of the displacements, satisfaction of interlaminar transverse shear stresses, the conditions of zero transverse shear stresses on the upper and lower surfaces and in-plane and transverse flexibility of soft core are considered for accurate modeling and analysis of sandwich structures. Solution for bending analysis of sandwich plates under various transverse loads are presented and the effect of many parameters such as plate dimensions, loading conditions, material properties of core, skins and SMA wires are studied. Comparison of the present results in special case with those of the three-dimensional theory of elasticity and some plate theories confirms the accuracy of the proposed model.


2009 ◽  
Vol 131 (6) ◽  
Author(s):  
Omotunde M. Babalola ◽  
Lawrence J. Bonassar

While mechanical stimulation of cells seeded within scaffolds is widely thought to be beneficial, the amount of benefit observed is highly variable between experimental systems. Although studies have investigated specific experimental loading protocols thought to be advantageous for cartilage growth, less is known about the physical stimuli (e.g., pressures, velocities, and local strains) cells experience during these experiments. This study used results of a literature survey, which looked for patterns in the efficacy of mechanical stimulation of chondrocyte seeded scaffolds, to inform the modeling of spatial patterns of physical stimuli present in mechanically stimulated constructs. The literature survey revealed a large variation in conditions used in mechanical loading studies, with a peak to peak strain of 10% (i.e., the maximum amount of deformation experienced by the scaffold) at 1 Hz on agarose scaffolds being the most frequently studied parameters and scaffold. This loading frequency was then used as the basis for simulation in the finite element analyses. 2D axisymmetric finite element models of 2×4 mm2 scaffolds with 360 modulus/permeability combinations were constructed using COMSOLMULTIPHYSICS software. A time dependent coupled pore pressure/effective stress analysis was used to model fluid/solid interactions in the scaffolds upon loading. Loading was simulated using an impermeable frictionless loader on the top boundary with fluid and solid displacement confined to the radial axis. As expected, all scaffold materials exhibited classic poro-elastic behavior having pressurized cores with low fluid flow and edges with high radial fluid velocities. Under the simulation parameters of this study, PEG scaffolds had the highest pressure and radial fluid velocity but also the lowest shear stress and radial strain. Chitosan and KLD-12 simulated scaffold materials had the lowest radial strains and fluid velocities, with collagen scaffolds having the lowest pressures. Parametric analysis showed maximum peak pressures within the scaffold to be more dependent on scaffold modulus than on permeability and velocities to depend on both scaffold properties similarly. The dependence of radial strain on permeability or modulus was more complex; maximum strains occurred at lower permeabilities and moduli, and the lowest strain occurred at the stiffest most permeable scaffold. Shear stresses within all scaffolds were negligible. These results give insight into the large variations in metabolic response seen in studies involving mechanical stimulation of cell-seeded constructs, where the same loading conditions produce very different results due to the differences in material properties.


2021 ◽  
Vol 63 (11) ◽  
pp. 1007-1011
Author(s):  
İsmail Saraç

Abstract This study was carried out in two stages. In the first step, a numerical study was performed to verify the previous experimental study. In accordance with the previous experimental study data, single lap joints models were created using the ANSYS finite element analysis program. Then, nonlinear stress and failure analyses were performed by applying the failure loads obtained in the experimental study. The maximum stress theory was used to find finite element failure loads of the single lap joints models. As a result of the finite element analysis, an approximate 80 % agreement was found between experimental and numerical results. In the second step of the study, in order to increase the bond strength, different overlap end geometry models were produced and peel and shear stresses in the adhesive layer were compared according to the reference model. As a result of the analyses, significant strength increases were calculated according to the reference model. The strength increase in model 3 and model 5 was found to be 80 % and 67 %, respectively, relative to the reference model.


Sign in / Sign up

Export Citation Format

Share Document