scholarly journals Coherent Image Source Modeling of Sound Fields in Long Spaces with a Sound-Absorbing Ceiling

2021 ◽  
Vol 11 (15) ◽  
pp. 6743
Author(s):  
Hequn Min ◽  
Ke Xu

Sound-absorbing boundaries can attenuate noise propagation in practical long spaces, but fast and accurate sound field modeling in this situation is still difficult. This paper presents a coherent image source model for simple yet accurate prediction of the sound field in long enclosures with a sound absorbing ceiling. In the proposed model, the reflections on the absorbent boundary are separated from those on reflective ones during evaluating reflection coefficients. The model is compared with the classic wave theory, an existing coherent image source model and a scale-model experiment. The results show that the proposed model provides remarkable accuracy advantage over the existing models yet is fast for sound prediction in long spaces.

2019 ◽  
Vol 2019 ◽  
pp. 1-10 ◽  
Author(s):  
Haisen Li ◽  
Jingxin Ma ◽  
Jianjun Zhu ◽  
Baowei Chen

The Khokhlov–Zabolotskaya–Kuznetsov (KZK) equation has been widely used in the simulation and calculation of nonlinear sound fields. However, the accuracy of KZK equation reduced due to the deflection of the direction of the sound beam when the sound beam is inclined incidence. In this paper, an equivalent sound source model is proposed to make the calculation direction of KZK calculation model consistent with the sound propagation direction after acoustic refraction, so as to improve the accuracy of sound field calculation under the inclined incident conditions. The theoretical research and pool experiment verify the feasibility and effectiveness of the proposed method.


1992 ◽  
Vol 92 (4) ◽  
pp. 2346-2346 ◽  
Author(s):  
Bengt‐Inge Dalenbäck ◽  
Peter Svensson ◽  
Mendel Kleiner
Keyword(s):  

2021 ◽  
Vol 11 (6) ◽  
pp. 2722
Author(s):  
Zhiwen Qian ◽  
Dejiang Shang ◽  
Yuan Hu ◽  
Xinyang Xu ◽  
Haihan Zhao ◽  
...  

The Green’s function (GF) directly eases the efficient computation for acoustic radiation problems in shallow water with the use of the Helmholtz integral equation. The difficulty in solving the GF in shallow water lies in the need to consider the boundary effects. In this paper, a rigorous theoretical model of interactions between the spherical wave and the liquid boundary is established by Fourier transform. The accurate and adaptive GF for the acoustic problems in the Pekeris waveguide with lossy seabed is derived, which is based on the image source method (ISM) and wave acoustics. First, the spherical wave is decomposed into plane waves in different incident angles. Second, each plane wave is multiplied by the corresponding reflection coefficient to obtain the reflected sound field, and the field is superposed to obtain the reflected sound field of the spherical wave. Then, the sound field of all image sources and the physical source are summed to obtain the GF in the Pekeris waveguide. The results computed by this method are compared with the standard wavenumber integration method, which verifies the accuracy of the GF for the near- and far-field acoustic problems. The influence of seabed attenuation on modal interference patterns is analyzed.


2001 ◽  
Vol 105 (1053) ◽  
pp. 627-631
Author(s):  
P. Traub ◽  
F. Kennepohl ◽  
K. Heinig

Abstract Under the national research project, dubbed Turbotech II, in which MTU Aero Engines, DLR Institute of Propulsion Technology and EADS Corporate Research Centre participate, active noise control (ANC) has been tested with a scale model fan of one metre diameter for a high bypass ratio aeroengine. MTU’s task in this project was to develop a computer code to predict the sound field in the intake duct of the fan-rig by the use of active control. The primary objective of the numerical study was to specify numbers of actuators (loudspeakers) and error sensors (microphones) and their positioning to control the harmonic sound power, radiated upstream to the duct intake. The computer model is based on the geometry of an annular or circular duct of rigid walls and infinite length, containing a subsonic axial uniform flow. The modal amplitudes of the primary sound field are input data. The actuators are modelled by acoustic monopoles. Two control algorithms have been used for achieving the control objective. The first consists simply in the reduction of the in-duct mean squared pressures. The second, so called modal control, is designed to cancel dominant modes selectively. Numerical results are presented using a typical configuration of wall mounted actuators and error sensors in the form of a number of rings uniformly distributed along the length of the intake duct. Guidelines have also been derived to design a favourable configuration of actuators and sensors. The findings of the numerical study are compared with the results of the ANC tests.


2021 ◽  
Vol 8 (12) ◽  
Author(s):  
Ulin Nuha A. Qohar ◽  
Antonella Zanna Munthe-Kaas ◽  
Jan Martin Nordbotten ◽  
Erik Andreas Hanson

In the last decade, numerical models have become an increasingly important tool in biological and medical science. Numerical simulations contribute to a deeper understanding of physiology and are a powerful tool for better diagnostics and treatment. In this paper, a nonlinear multi-scale model framework is developed for blood flow distribution in the full vascular system of an organ. We couple a quasi one-dimensional vascular graph model to represent blood flow in larger vessels and a porous media model to describe flow in smaller vessels and capillary bed. The vascular model is based on Poiseuille’s Law, with pressure correction by elasticity and pressure drop estimation at vessels' junctions. The porous capillary bed is modelled as a two-compartment domain (artery and venous) using Darcy’s Law. The fluid exchange between the artery and venous capillary bed compartments is defined as blood perfusion. The numerical experiments show that the proposed model for blood circulation: (i) is closely dependent on the structure and parameters of both the larger vessels and of the capillary bed, and (ii) provides a realistic blood circulation in the organ. The advantage of the proposed model is that it is complex enough to reliably capture the main underlying physiological function, yet highly flexible as it offers the possibility of incorporating various local effects. Furthermore, the numerical implementation of the model is straightforward and allows for simulations on a regular desktop computer.


2022 ◽  
Vol 12 (2) ◽  
pp. 567
Author(s):  
Young-Hak Lee ◽  
Jung-Hyun Ryu ◽  
Joon Heo ◽  
Jae-Woong Shim ◽  
Dal-Won Lee

In recent years, as the number of reservoir embankments constructed has increased, embankment failures due to cracks in aging conduits have also increased. In this study, a crack in a conduit was modeled based on the current conduit design model, and the risk of internal erosion was analyzed using a large-scale model test and three-dimensional deformation–seepage analysis. The results show that when cracks existed in the conduit, soil erosion and cavitation occurred near the crack area, which made the conduit extremely vulnerable to internal erosion. Herein, a model is proposed that can reduce internal erosion by applying a layer of sand and geotextiles on the upper part of the conduit located close to the downstream slope. In the proposed model, only partial erosion occurred inside the conduit, and no cavitation appeared near the crack in the conduit. The results suggest that internal erosion can be suppressed when the water pressure acting intensively on the crack in the conduit is dispersed by the drainage layer. To validate these results, the pore water pressure, seepage line, and hydraulic gradient were investigated to confirm the erosion phenomenon and reinforcement effect.


Author(s):  
Heather L. Lai ◽  
Brian Hamilton

Abstract This paper investigates the use of two room acoustics metrics designed to evaluate the degree to which the linearity assumptions of the energy density curves are valid. The study focuses on measured and computer-modeled energy density curves derived from the room impulse response of a space exhibiting a highly non-diffuse sound field due to flutter echo. In conjunction with acoustical remediation, room impulse response measurements were taken before and after the installation of the acoustical panels. A very dramatic decrease in the reverberation time was experienced due to the addition of the acoustical panels. The two non-linearity metrics used in this study are the non-linearity parameter and the curvature. These metrics are calculated from the energy decay curves computed per octave band, based on the definitions presented in ISO 3382-2. The non-linearity parameter quantifies the deviation of the EDC from a straight line fit used to generated T20 and T30 reverberation times. Where the reverberation times are calculated based on a linear regression of the data relating to either −5 to −25 dB for T20 or −5 to −35 dB for T30 reverberation time calculations. This deviation is quantified using the correlation coefficient between the energy decay curve and the linear regression for the specified data. In order to graphically demonstrate these non-linearity metrics, the energy decay curves are plotted along with the linear regression curves for the T20 and T30 reverberation time for both the measured data and two different room acoustics computer-modeling techniques, geometric acoustics modeling and finite-difference wave-based modeling. The intent of plotting these curves together is to demonstrate the relationship between these metrics and the energy decay curve, and to evaluate their use for quantifying degree of non-linearity in non-diffuse sound fields. Observations of these graphical representations are used to evaluate the accuracy of reverberation time estimations in non-diffuse environments, and to evaluate the use of these non-linearity parameters for comparison of different computer-modeling techniques or room configurations. Using these techniques, the non-linearity parameter based on both T20 and T30 linear regression curves and the curvature parameter were calculated over 250–4000 Hz octave bands for the measured and computer-modeled room impulse response curves at two different locations and two different room configurations. Observations of these calculated results are used to evaluate the consistency of these metrics, and the application of these metrics to quantifying the degree of non-linearity of the energy decay curve derived from a non-diffuse sound field. These calculated values are also used to evaluate the differences in the degree of diffusivity between the measured and computer-modeled room impulse response. Acoustical computer modeling is often based on geometrical acoustics using ray-tracing and image-source algorithms, however, in non-diffuse sound fields, wave based methods are often able to better model the characteristic sound wave patterns that are developed. It is of interest to study whether these improvements in the wave based computer-modeling are also reflected in the non-linearity parameter calculations. The results showed that these metrics provide an effective criteria for identifying non-linearity in the energy decay curve, however for highly non-diffuse sound fields, the resulting values were found to be very sensitive to fluctuations in the energy decay curves and therefore, contain inconsistencies due to these differences.


2021 ◽  
Vol 263 (1) ◽  
pp. 5571-5577
Author(s):  
Reiji Tomiku ◽  
Noriko Okamoto ◽  
Toru Otsuru ◽  
Shun Iwamoto ◽  
Shoma Suzuki

The absorption coefficients in a reverberation room are most representative measure for evaluating absorption performance of architectural materials. However, it is well known that measurement results of the coefficient vary according to a room shape of the measurement and area of the specimen. Numerical analyses based on wave acoustics are effective tools to investigate these factors on absorption coefficient measurement in reverberation room. In this study, sound fields for the measurement of absorption coefficient in reverberation room are analyzed by time domain finite element method (TDFEM). This study shows effectiveness of the analysis for investigation on causes of variation in the measurement results and improvement methods of the measurement. First, some measurement sound fields for absorption coefficient in reverberation rooms the walls of which are incline or decline are analyzed by the TDFEM. Next, reverberation times in each sound fields are calculated from the results obtained by TDFEM and the absorption coefficients are evaluated from the reverberation time of the room with and without specimen. Finally, the relationships among room shape, degree of inclination of the wall, the sound absorption coefficient of the specimen, frequencies and the measurement absorption coefficient are investigated.


Sign in / Sign up

Export Citation Format

Share Document