scholarly journals Ventilation Systems and Their Impact on Nanoparticle Concentrations in Office Buildings

2021 ◽  
Vol 11 (19) ◽  
pp. 8930
Author(s):  
Henrik Olstrup ◽  
Annika Hagenbjörk ◽  
Hans Orru

Nanoparticles (NPs) can infiltrate indoor environments and have a large impact on human health when inhaled. Thus, indoor air quality is highly dependent on the outdoor air and on the filters used in the ventilation systems. In the NanoOffice study, the concentrations and the size distribution of NPs were measured with a five-minute time resolution in twelve office buildings in Umeå. Measurements were taken with an SMPS 3938 during a one-week period in the heating and nonheating seasons. Large differences in ventilation between buildings appeared, despite the fact that similar MVHR ventilation systems were used, and most of them were equipped with F7 filters. The NP concentrations and the simultaneous ventilation flows were measured in buildings with a variable and a more constant ventilation flow. In some cases, an increase in NP concentration could be seen after ventilation turn-on or after an increase in the ventilation flow. There was also one case where the NP concentrations increased in connection with the ventilation being switched off or reducing its flow. However, variable NP concentrations were also shown in buildings with a fairly constant ventilation flow, which was prominent for the two buildings located closest to busy streets. The correlation coefficients between the ventilation flow and particles in different size classes were in general smallest for particles in the smallest size classes, indicating higher filtration efficiency.

1989 ◽  
Vol 15 (1-6) ◽  
pp. 115-128 ◽  
Author(s):  
A. Hedge ◽  
T.D. Sterling ◽  
E.M. Sterling ◽  
C.W. Collett ◽  
D.A. Sterling ◽  
...  

2018 ◽  
Vol 28 ◽  
pp. 01022 ◽  
Author(s):  
Anna Mainka ◽  
Elwira Zajusz-Zubek ◽  
Barbara Kozielska ◽  
Ewa Brągoszewska

Children’s exposure to air pollutants is an important public health challenge. Indoor air quality (IAQ) in nursery school is believed to be different from elementary school. Moreover, younger children are more vulnerable to air pollution than higher grade children because they spend more time indoors, and their immune systems and bodies are less mature. The purpose of this study was to evaluate the indoor air quality (IAQ) at naturally ventilated rural nursery schools located in Upper Silesia, Poland. We investigated the concentrations of volatile organic compounds (VOCs), particulate matter (PM), bacterial and fungal bioaerosols, as well as carbon dioxide (CO2) concentrations in younger and older children's classrooms during the winter and spring seasons. The concentration of the investigated pollutants in indoor environments was higher than those in outdoor air. The results indicate the problem of elevated concentrations of PM2.5 and PM10 inside the examined classrooms, as well as that of high levels of CO2 exceeding 1,000 ppm in relation to outdoor air. The characteristics of PM and CO2 levels were significantly different, both in terms of classroom occupation (younger or older children) and of season (winter or spring).


2019 ◽  
Vol 111 ◽  
pp. 06047
Author(s):  
Motoya Hayashi ◽  
Hoon kim ◽  
Yoshinori Honma ◽  
Junichiro Matsunaga

In order to retain good indoor air quality through the year in detached houses with passive ventilation systems, the authors investigated a mechanical control air-supply method. Firstly, indoor environments in houses with passive ventilation systems with thermal dampers, were examined using a simulation program (Fresh). Secondly, a passive ventilation system with a thermal damper, an under-floorheating system with a heat pump and were installed in an airtight house at Maebashi in Japan and measurements on its ventilation characteristics and indoor air quality were made. The simulation results showed that if the thermal damper is well tuned, this mechanically controlled air-supply opening keeps ventilation rates adequate through the year especially in airtight houses. The measurement results showed that the ventilation rates were kept above the required level through the year and the TVOC concentration decreases from 3000 to 200 μg/m3 in 5 months after the construction.


2011 ◽  
Vol 20 (1) ◽  
pp. 187-197 ◽  
Author(s):  
Min Jeong Kim ◽  
Yong Su Kim ◽  
Abtin Ataei ◽  
Jeong Tai Kim ◽  
Jung Jin Lim ◽  
...  

The purpose of this study was to evaluate changes in the concentration of air pollutants in the indoor environments, which could be caused by seasonal changes or changes in operating conditions of subway metro stations. In fact, there are many different types of pollution that can cause contamination in subway stations, and changes in operating conditions can also lead to changes in the indoor air quality (IAQ). Therefore, in order to establish a proper management of IAQ, it would be necessary to evaluate the changes in IAQ according to the changes in conditions. To do this, the present study used a multivariate analysis of variance (MANOVA). The results of testing the hypothesis proved that two groups, divided by the condition of a platform screen door (PSD) system, could differ statistically. Furthermore, those multidimensional differences were caused by installation of a PSD system. When applied to a real-time tele-monitoring system, MANOVA could clearly identify the daily and weekly variations of IAQ in the subway station, as well as the PSD system’s condition. Accordingly, this method could be useful for developing a multivariate system to statistically evaluate the experimental IAQ results in order to optimise operating conditions in a subway metro station to improve IAQ, and to minimise adverse health effects on passengers by exposure to harmful substances.


Author(s):  
T. Faria ◽  
M. Almeida Silva ◽  
Ana Dias ◽  
S.M. Almeida

2019 ◽  
Vol 11 (17) ◽  
pp. 4791
Author(s):  
Kwag ◽  
Park ◽  
Kim ◽  
Kim

Building air-tightness has been increased to make energy efficient buildings. However, various indoor air quality issues can be caused by high building air-tightness because it allows low air and moisture transmission through building envelop. In order to solve and prevent these issues, mechanical ventilation systems can be used to control the indoor humidity level. The purpose of this paper is to evaluate the performances of the Relative Humidity (RH)-sensor based auto-controlled centralized exhaust ventilation systems to manage indoor air quality and thermal comfort of multi-family residential buildings in South Korea. A series of field tests were performed for different target zones and for various moisture source scenarios. As a result, it was found that the auto-controlled centralized exhaust ventilation systems were able to control indoor air quality and to maintain the zones thermal comfort faster than the baseline cases that did not operate exhaust vents. The results presented in this paper can show the potential and the feasibility of the auto-controlled centralized exhaust ventilation systems for multi-family residential buildings in South Korea. It is expected that the results presented in this paper would be useful for building owners, engineers, and architects when designing building systems.


Sign in / Sign up

Export Citation Format

Share Document