scholarly journals Enabling Continuous Wearable Reflectance Pulse Oximetry at the Sternum

Biosensors ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 521
Author(s):  
Michael Chan ◽  
Venu G. Ganti ◽  
J. Alex Heller ◽  
Calvin A. Abdallah ◽  
Mozziyar Etemadi ◽  
...  

In light of the recent Coronavirus disease (COVID-19) pandemic, peripheral oxygen saturation (SpO2) has shown to be amongst the vital signs most indicative of deterioration in persons with COVID-19. To allow for the continuous monitoring of SpO2, we attempted to demonstrate accurate SpO2 estimation using our custom chest-based wearable patch biosensor, capable of measuring electrocardiogram (ECG) and photoplethysmogram (PPG) signals with high fidelity. Through a breath-hold protocol, we collected physiological data with a wide dynamic range of SpO2 from 20 subjects. The ratio of ratios (R) used in pulse oximetry to estimate SpO2 was robustly extracted from the red and infrared PPG signals during the breath-hold segments using novel feature extraction and PPGgreen-based outlier rejection algorithms. Through subject independent training, we achieved a low root-mean-square error (RMSE) of 2.64 ± 1.14% and a Pearson correlation coefficient (PCC) of 0.89. With subject-specific calibration, we further reduced the RMSE to 2.27 ± 0.76% and increased the PCC to 0.91. In addition, we showed that calibration is more efficiently accomplished by standardizing and focusing on the duration of breath-hold rather than the resulting range in SpO2. The accurate SpO2 estimation provided by our custom biosensor and the algorithms provide research opportunities for a wide range of disease and wellness monitoring applications.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ibtissame Khaoua ◽  
Guillaume Graciani ◽  
Andrey Kim ◽  
François Amblard

AbstractFor a wide range of purposes, one faces the challenge to detect light from extremely faint and spatially extended sources. In such cases, detector noises dominate over the photon noise of the source, and quantum detectors in photon counting mode are generally the best option. Here, we combine a statistical model with an in-depth analysis of detector noises and calibration experiments, and we show that visible light can be detected with an electron-multiplying charge-coupled devices (EM-CCD) with a signal-to-noise ratio (SNR) of 3 for fluxes less than $$30\,{\text{photon}}\,{\text{s}}^{ - 1} \,{\text{cm}}^{ - 2}$$ 30 photon s - 1 cm - 2 . For green photons, this corresponds to 12 aW $${\text{cm}}^{ - 2}$$ cm - 2 ≈ $$9{ } \times 10^{ - 11}$$ 9 × 10 - 11 lux, i.e. 15 orders of magnitude less than typical daylight. The strong nonlinearity of the SNR with the sampling time leads to a dynamic range of detection of 4 orders of magnitude. To detect possibly varying light fluxes, we operate in conditions of maximal detectivity $${\mathcal{D}}$$ D rather than maximal SNR. Given the quantum efficiency $$QE\left( \lambda \right)$$ Q E λ of the detector, we find $${ \mathcal{D}} = 0.015\,{\text{photon}}^{ - 1} \,{\text{s}}^{1/2} \,{\text{cm}}$$ D = 0.015 photon - 1 s 1 / 2 cm , and a non-negligible sensitivity to blackbody radiation for T > 50 °C. This work should help design highly sensitive luminescence detection methods and develop experiments to explore dynamic phenomena involving ultra-weak luminescence in biology, chemistry, and material sciences.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1263
Author(s):  
Tobias Dünnwald ◽  
Roland Kienast ◽  
David Niederseer ◽  
Martin Burtscher

Background: Finger pulse oximeters are widely used to monitor physiological responses to high-altitude exposure, the progress of acclimatization, and/or the potential development of high-altitude related diseases. Although there is increasing evidence for its invaluable support at high altitude, some controversy remains, largely due to differences in individual preconditions, evaluation purposes, measurement methods, the use of different devices, and the lacking ability to interpret data correctly. Therefore, this review is aimed at providing information on the functioning of pulse oximeters, appropriate measurement methods and published time courses of pulse oximetry data (peripheral oxygen saturation, (SpO2) and heart rate (HR), recorded at rest and submaximal exercise during exposure to various altitudes. Results: The presented findings from the literature review confirm rather large variations of pulse oximetry measures (SpO2 and HR) during acute exposure and acclimatization to high altitude, related to the varying conditions between studies mentioned above. It turned out that particularly SpO2 levels decrease with acute altitude/hypoxia exposure and partly recover during acclimatization, with an opposite trend of HR. Moreover, the development of acute mountain sickness (AMS) was consistently associated with lower SpO2 values compared to individuals free from AMS. Conclusions: The use of finger pulse oximetry at high altitude is considered as a valuable tool in the evaluation of individual acclimatization to high altitude but also to monitor AMS progression and treatment efficacy.


1987 ◽  
Vol 121 ◽  
pp. 287-293
Author(s):  
C.J. Schalinski ◽  
P. Biermann ◽  
A. Eckart ◽  
K.J. Johnston ◽  
T.Ph. Krichbaum ◽  
...  

A complete sample of 13 flat spectrum radio sources is investigated over a wide range of frequencies and spatial resolutions. SSC-calculations lead to the prediction of bulk relativistic motion in all sources. So far 6 out of 7 sources observed with sufficient dynamic range by means of VLBI show evidence for apparent superluminal motion.


2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Jie Liao ◽  
Lan Yang

AbstractTemperature is one of the most fundamental physical properties to characterize various physical, chemical, and biological processes. Even a slight change in temperature could have an impact on the status or dynamics of a system. Thus, there is a great need for high-precision and large-dynamic-range temperature measurements. Conventional temperature sensors encounter difficulties in high-precision thermal sensing on the submicron scale. Recently, optical whispering-gallery mode (WGM) sensors have shown promise for many sensing applications, such as thermal sensing, magnetic detection, and biosensing. However, despite their superior sensitivity, the conventional sensing method for WGM resonators relies on tracking the changes in a single mode, which limits the dynamic range constrained by the laser source that has to be fine-tuned in a timely manner to follow the selected mode during the measurement. Moreover, we cannot derive the actual temperature from the spectrum directly but rather derive a relative temperature change. Here, we demonstrate an optical WGM barcode technique involving simultaneous monitoring of the patterns of multiple modes that can provide a direct temperature readout from the spectrum. The measurement relies on the patterns of multiple modes in the WGM spectrum instead of the changes of a particular mode. It can provide us with more information than the single-mode spectrum, such as the precise measurement of actual temperatures. Leveraging the high sensitivity of WGMs and eliminating the need to monitor particular modes, this work lays the foundation for developing a high-performance temperature sensor with not only superior sensitivity but also a broad dynamic range.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1393
Author(s):  
Uduak Z. George ◽  
Kee S. Moon ◽  
Sung Q. Lee

Respiratory activity is an important vital sign of life that can indicate health status. Diseases such as bronchitis, emphysema, pneumonia and coronavirus cause respiratory disorders that affect the respiratory systems. Typically, the diagnosis of these diseases is facilitated by pulmonary auscultation using a stethoscope. We present a new attempt to develop a lightweight, comprehensive wearable sensor system to monitor respiration using a multi-sensor approach. We employed new wearable sensor technology using a novel integration of acoustics and biopotentials to monitor various vital signs on two volunteers. In this study, a new method to monitor lung function, such as respiration rate and tidal volume, is presented using the multi-sensor approach. Using the new sensor, we obtained lung sound, electrocardiogram (ECG), and electromyogram (EMG) measurements at the external intercostal muscles (EIM) and at the diaphragm during breathing cycles with 500 mL, 625 mL, 750 mL, 875 mL, and 1000 mL tidal volume. The tidal volumes were controlled with a spirometer. The duration of each breathing cycle was 8 s and was timed using a metronome. For each of the different tidal volumes, the EMG data was plotted against time and the area under the curve (AUC) was calculated. The AUC calculated from EMG data obtained at the diaphragm and EIM represent the expansion of the diaphragm and EIM respectively. AUC obtained from EMG data collected at the diaphragm had a lower variance between samples per tidal volume compared to those monitored at the EIM. Using cubic spline interpolation, we built a model for computing tidal volume from EMG data at the diaphragm. Our findings show that the new sensor can be used to measure respiration rate and variations thereof and holds potential to estimate tidal lung volume from EMG measurements obtained from the diaphragm.


2010 ◽  
Vol 1 (SRMS-7) ◽  
Author(s):  
David Pennicard ◽  
Heinz Graafsma ◽  
Michael Lohmann

The new synchrotron light source PETRA-III produced its first beam last year. The extremely high brilliance of PETRA-III and the large energy range of many of its beamlines make it useful for a wide range of experiments, particularly in materials science. The detectors at PETRA-III will need to meet several requirements, such as operation across a wide dynamic range, high-speed readout and good quantum efficiency even at high photon energies. PETRA-III beamlines with lower photon energies will typically be equipped with photon-counting silicon detectors for two-dimensional detection and silicon drift detectors for spectroscopy and higher-energy beamlines will use scintillators coupled to cameras or photomultiplier tubes. Longer-term developments include ‘high-Z’ semiconductors for detecting high-energy X-rays, photon-counting readout chips with smaller pixels and higher frame rates and pixellated avalanche photodiodes for time-resolved experiments.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Doil Kim ◽  
Jiyoung Choi ◽  
Duhgoon Lee ◽  
Hyesun Kim ◽  
Jiyoung Jung ◽  
...  

AbstractA novel motion correction algorithm for X-ray lung CT imaging has been developed recently. It was designed to perform for routine chest or thorax CT scans without gating, namely axial or helical scans with pitch around 1.0. The algorithm makes use of two conjugate partial angle reconstruction images for motion estimation via non-rigid registration which is followed by a motion compensated reconstruction. Differently from other conventional approaches, no segmentation is adopted in motion estimation. This makes motion estimation of various fine lung structures possible. The aim of this study is to explore the performance of the proposed method in correcting the lung motion artifacts which arise even under routine CT scans with breath-hold. The artifacts are known to mimic various lung diseases, so it is of great interest to address the problem. For that purpose, a moving phantom experiment and clinical study (seven cases) were conducted. We selected the entropy and positivity as figure of merits to compare the reconstructed images before and after the motion correction. Results of both phantom and clinical studies showed a statistically significant improvement by the proposed method, namely up to 53.6% (p < 0.05) and up to 35.5% (p < 0.05) improvement by means of the positivity measure, respectively. Images of the proposed method show significantly reduced motion artifacts of various lung structures such as lung parenchyma, pulmonary vessels, and airways which are prominent in FBP images. Results of two exemplary cases also showed great potential of the proposed method in correcting motion artifacts of the aorta which is known to mimic aortic dissection. Compared to other approaches, the proposed method provides an excellent performance and a fully automatic workflow. In addition, it has a great potential to handle motions in wide range of organs such as lung structures and the aorta. We expect that this would pave a way toward innovations in chest and thorax CT imaging.


Circulation ◽  
2014 ◽  
Vol 130 (suppl_2) ◽  
Author(s):  
Craig G Rusin ◽  
Sebastian I Acosta ◽  
Eric L Vu ◽  
Risa B Myers ◽  
Kenneth M Brady ◽  
...  

Patients after stage 1 palliation (S1P) for hypoplastic left heart syndrome (HLHS) and related lesions are at risk of life threatening deterioration resulting in shock, cardiac arrest, & hypoxemia. We hypothesize that these sudden deteriorations may be forecast by subtle, previously unidentified changes in cardiorespiratory dynamics. Identification of these precursors may provide an opportunity for early, life-saving intervention. We created complete high-resolution physiological recordings for all patients who had a primary admission of S1P after Jan. 1, 2013. We used the SickbayTM system (Medical Informatics Corp, Houston, TX) to collect high frequency physiological waveforms including EKG, ABP, LAP, SpO2 and Chest Impedance (60Hz - 240Hz), as well as HR, RR, Temp. and ST segment vital signs (0.5 Hz) during the patient’s interstage hospitalization. A logistic regression model was constructed to discriminate between physiological characteristics observed in the hours prior to deterioration from the characteristics observed >24 hours prior to or >96 hours after a clinical deterioration. Model validation was done using a standard bagging approach with a REPtree classifier and 10 fold cross validation. Twenty five patients were included in the study. Of these, 15 (60%) were found to have one or more deterioration events (arrest, CPR, unplanned intubation), with 24 total events observed during the interstage period. Characteristics associated with imminent deterioration were low SpO2 and depressed ST segment. Changes in physiological dynamics could be detected 1-2 hours before overt deterioration occurs (ROC area = 0.89) (Figure 1). This altered physiological state remains for ~96 hours after deterioration. In conclusion, it is possible to identify clinical deterioration in HLHS patients during their interstage period ~1-2 hours before overt deterioration occurs, providing an opportunity for early, life-saving intervention to be administered.


2007 ◽  
Vol 16 (1) ◽  
pp. 119-122 ◽  
Author(s):  
Patrick Ledda

In the natural world, the human eye is confronted with a wide range of colors and luminances. A surface lit by moonlight might have a luminance level of around 10−3 cd/m2, while surfaces lit during a sunny day could reach values larger than 105 cd/m2. A good quality CRT (cathode ray tube) or LCD (liquid crystal display) monitor is only able to achieve a maximum luminance of around 200 to 300 cd/m2 and a contrast ratio of not more than two orders of magnitude. In this context the contrast ratio or dynamic range is defined as the ratio of the highest to the lowest luminance. We call high dynamic range (HDR) images, those images (or scenes) in which the contrast ratio is larger than what a display can reproduce. In practice, any scene that contains some sort of light source and shadows is HDR. The main problem with HDR images is that they cannot be displayed, therefore although methods to create them do exist (by taking multiple photographs at different exposure times or using computer graphics 3D software for example) it is not possible to see both bright and dark areas simultaneously. (See Figure 1.) There is data that suggests that our eyes can see detail at any given adaptation level within a contrast of 10,000:1 between the brightest and darkest regions of a scene. Therefore an ideal display should be able to reproduce this range. In this review, we present two high dynamic range displays developed by Brightside Technologies (formerly Sunnybrook Technologies) which are capable, for the first time, of linearly displaying high contrast images. These displays are of great use for both researchers in the vision/graphics/VR/medical fields as well as professionals in the VFX/gaming/architectural industry.


2015 ◽  
Vol 61 (225) ◽  
pp. 89-100 ◽  
Author(s):  
Cameron Lewis ◽  
Sivaprasad Gogineni ◽  
Fernando Rodriguez-Morales ◽  
Ben Panzer ◽  
Theresa Stumpf ◽  
...  

AbstractWe have built and operated an ultra-wideband UHF pulsed-chirp radar for measuring firn stratigraphy from airborne platforms over the ice sheets of Greenland and West Antarctica. Our analysis found a wide range of capabilities, including imaging of post firn–ice transition horizons and sounding of shallow glaciers and ice shelves. Imaging of horizons to depths exceeding 600 m was possible in the colder interior regions of the ice sheet, where scattering from the ice surface and inclusions was minimal. The radar’s high sensitivity and large dynamic range point to loss tangent variations as the dominant mechanism for these englacial reflective horizons. The radar is capable of mapping interfaces with reflection coefficients as low as −80 dB near the firn–ice transition and as low as −64 dB at depths of 600 m. We found that firn horizon reflectivity strongly mirrored density variance, a result of the near-unity interfacial transmission coefficients. Zones with differing compaction mechanisms were also apparent in the data. We were able to sound many ice shelves and areas of shallow ice. We estimated ice attenuation rates for a few locations, and our attenuation estimates for the Ross Ice Shelf, West Antarctica, appear to agree well with earlier reported results.


Sign in / Sign up

Export Citation Format