scholarly journals Diagnostic Three Slides Pap Test Compared to Punch Biopsy and Endocervical Curettage in Confirmed HSIL+ Diagnosis

Diagnostics ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 942
Author(s):  
Roberta Rubeša-Mihaljević ◽  
Danijela Vrdoljak-Mozetič ◽  
Morana Dinter ◽  
Damjana Verša Ostojić ◽  
Snježana Štemberger-Papić ◽  
...  

Objective: The aim of the study was to evaluate the accuracy of the diagnostic Pap test (DPT) on three slides and punch biopsy and endocervical curettage (PB/ECC) compared with the final biopsy material in the detection of high-grade squamous intraepithelial lesion (HSIL). Materials and methods: Patients treated with conization after previous DPT and PB/ECC were analyzed. The findings of the DPT and PB/ECC as well as of the endocervical brush cytology and ECC were compared with the final conus histology. Results: 150 patients were analyzed, and final histology verified 145 cases of HSIL and 3 cancers. The percentage of confirmed HSIL cytology was 97%, while for PB/ECC it was 79% with 30/145 false negative results. The correlation between Pap test and PB/ECC showed that the diagnostic accuracy of DPT is significantly higher (p < 0.0001). Endocervical brush cytology confirmed HSIL+ in the endocervical canal in 83% and ECC in 35% of cases (p < 0.0001). Conclusion: The DPT on three slides enables better detection of HSIL compared to PB/ECC, particularly for lesions localized in the endocervical canal sampled with a cytobrush. A high quality DPT could represent a surrogate for PB/ECC and open the possibility of direct access to therapeutic procedure.

2018 ◽  
Vol 62 (2) ◽  
pp. 115-120
Author(s):  
Juliana Cristina Magalhães ◽  
Cinara Zago Silveira Ázara ◽  
Sulene Brito do Nascimento Tavares ◽  
Edna Joana Claudio Manrique ◽  
Rita Goreti Amaral

Objective: We aimed to evaluate the impact of implementing 100% rapid review (100% RR) as a quality control tool in cervical smear cytology. Design: A cross-sectional study was conducted in which cytology findings, false-negative results, and quality indicators were evaluated. The variables were analyzed in 2004, the year in which 100% RR was implemented, and again in 2013, i.e., 10 years on. Results: Detection of atypical squamous cells of undetermined significance (ASC-US) increased from 0.90% in 2004 to 2.47% in 2013 by routine screening. Detection of atypical squamous cells, cannot exclude a high-grade squamous intraepithelial lesion (ASC-H) increased from 13.33% in 2004 to 36.27% in 2013 by 100% RR. Detection of high-grade squamous intraepithelial lesion (HSIL) increased from 0.64% in 2004 to 4.29% in 2013 by routine screening, and increased from 0% in 2004 to 19.61% in 2013 by 100% RR. There was a significant increase (p = 0.00001) in the identification of false-negative results of ASC-US, low-grade squamous intraepithelial lesion, ASC-H, HSIL, and atypical glandular cells. All quality indicators had increased in 2013 when compared to 2004 results. Conclusions: Ten years after the implementation of the 100% RR method, improvements were found in the detection of atypia and precursor lesions and in quality indicators.


2019 ◽  
Vol 6 (4) ◽  
pp. 42-48
Author(s):  
S. V. Popov ◽  
R. G. Guseinov ◽  
I. N. Orlov ◽  
V. V. Protoshchak ◽  
O. N. Skryabin ◽  
...  

Introduction.Contemporary diagnosis of prostate cancer is crucial to the patient’s further fate. Difficulties in the histological verification of the final diagnosis and false-negative results of biopsy research are often associated with the similarity of the prostate adenocarcinoma`s micromorphological picture and its benign lesions.Purpose of the study.Comprehending the possibilities of immunohistochemical identification of tumor cells and the basal epithelial layer of prostate glandular structures in prostate cancer suspected cases.Materials and methods.A biopsy material was taken from 134 patients. Prostate adenocarcinoma was verified by routine histological examination in 72 samples, in 62 samples there were no signs of malignant transformation. Subsequently, immunohistochemical analysis of biopsy specimens was performed using antibodies to α-methylacyl-CoA racemase, nuclear p63 protein and high-molecular cytokeratin.Results.The AMACR-positive reaction of malignant cells and a negative reaction of the basal epithelium to nuclear p63 protein antibodies and high-molecular cytokeratin were detected during prostate adenocarcinoma.Conclusion.If prostate cancer is suspected, immunohistochemical assays with monoclonal antibodies to AMACR, p63 and high-molecular cytokeratin greatly facilitate the detection of adenocarcinoma.


1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


2020 ◽  
Vol 13 (1) ◽  
pp. 413-414 ◽  
Author(s):  
Mohamed Farouk Allam

Due to the international spread of COVID-19, the difficulty of collecting nasopharyngeal swab specimen from all suspected patients, the costs of RT-PCR and CT, and the false negative results of RT-PCR assay in 41% of COVID-19 patients, a scoring system is needed to classify the suspected patients in order to determine the need for follow-up, home isolation, quarantine or the conduction of further investigations. A scoring system is proposed as a diagnostic tool for suspected patients. It includes Epidemiological Evidence of Exposure, Clinical Symptoms and Signs, and Investigations (if available). This scoring system is simple, could be calculated in a few minutes, and incorporates the main possible data/findings of any patient.


2020 ◽  
Vol 18 ◽  
Author(s):  
Pegah Shakib ◽  
Mohammad Reza Zolfaghari

Background: Conventional laboratory culture-based methods for diagnosis of Streptococcus pneumoniae are time-consuming and yield false negative results. Molecular methods including real-time (RT)-PCR rapid methods and conventional PCR due to higher sensitivity and accuracy have been replaced instead traditional culture assay. The aim of the current study was to evaluate lytA gene for detection of Streptococcus pneumoniae in the cerebrospinal fluid of human patients with meningitis using real-time PCR assay. Material and Methods: In this cross-sectional study, a total of 30 clinical specimens were collected from patients in a period from September to December 2018. In order to evaluate the presence of lytA gene, conventional and real-time PCR methods were used without culture. Results: From 30 sputum samples five (16.66%) isolates were identified as S. pneumoniae by lytA PCR and sequencing. Discussion: In this research, an accurate and rapid real-time PCR method was used, which is based on lytA gene for diagnosis of bacteria so that it can be diagnosed. Based on the sequencing results, the sensitivity for detection of lytA gene was 100% (5/5).


Coronaviruses ◽  
2020 ◽  
Vol 01 ◽  
Author(s):  
Maria Silvia De Feo ◽  
Viviana Frantellizzi ◽  
Giuseppe De Vincentis

Background: We present the case of a 55-year-old woman, admitted to the Infectious Disease Department of Policlinico Umberto I, Rome, in mid-March 2020, with suspicion of COVID-19 infection. Objective: The rRT-PCR was negative and the following CT scan, performed to exclude false-negative results and help diagnosis, was inconclusive. Methods: It was decided to submit the patient to 99mTc-HMPAO-labelled leukocyte scan. Results: This exam led to the diagnosis of infective endocarditis. Conclusion: In the present pandemic scenario, 99mTc-HMPAO-labelled leukocyte scan represents a reliable imaging technique for differential diagnosis with COVID-19 in patients with confusing clinical signs, possible false-negative rRT-PCR results and inconclusive CT scan.


Author(s):  
Hyoung-Jin Moon ◽  
Won Lee ◽  
Ji-Soo Kim ◽  
Eun-Jung Yang ◽  
Hema Sundaram

Abstract Background Aspiration testing before filler injection is controversial. Some believe that aspiration can help prevent inadvertent intravascular injection, while others cite false-negative results and question its value given that the needle position always changes somewhat during injection procedures. Objectives To test the relation of false-negative results to the viscosity of the material within the needle lumen and determine whether a less viscous material within the needle lumen could decrease the incidence of false-negative results. Methods In vitro aspiration tests were performed using 30-G and 27-G needle gauges, two cross-linked hyaluronic acid fillers, normal saline bags pressurized at 140 and 10 mmHg to mimic human arterial and venous pressures, and three needle lumen conditions (normal saline, air, and filler). Testing was repeated three times under each study condition (72 tests in total). For in vivo correlation, aspiration tests were performed on femoral arteries and central auricular veins in three rabbits (4–5 aspirations per site, 48 tests in total). Results In vitro and in vivo testing using 30-G needles containing filler both showed false-negative results on aspiration testing. In vitro and in vivo testing using needles containing saline or air showed positive findings. Conclusions False-negative results from aspiration testing may be reduced by pre-filling the needle lumen with saline rather than a filler. The pressurized system may help overcome challenges of animal models with intravascular pressures significantly different from those of humans. The adaptability of this system to mimic various vessel pressures may facilitate physiologically relevant studies of vascular complications.


Viruses ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 730
Author(s):  
Magda Rybicka ◽  
Ewa Miłosz ◽  
Krzysztof Piotr Bielawski

At present, the RT-PCR test remains the gold standard for early diagnosis of SARS-CoV-2. Nevertheless, there is growing evidence demonstrating that this technique may generate false-negative results. Here, we aimed to compare the new mass spectrometry-based assay MassARRAY® SARS-CoV-2 Panel with the RT-PCR diagnostic test approved for clinical use. The study group consisted of 168 suspected patients with symptoms of a respiratory infection. After simultaneous analysis by RT-PCR and mass spectrometry methods, we obtained discordant results for 17 samples (10.12%). Within fifteen samples officially reported as presumptive positive, 13 were positive according to the MS-based assay. Moreover, four samples reported by the officially approved RT-PCR as negative were positive in at least one MS assay. We have successfully demonstrated superior sensitivity of the MS-based assay in SARS-CoV-2 detection, showing that MALDI-TOF MS seems to be ideal for the detection as well as discrimination of mutations within the viral genome.


Sign in / Sign up

Export Citation Format

Share Document