scholarly journals The Pulmonary Artery Catheter in the Perioperative Setting: Should It Still Be Used?

Diagnostics ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 177
Author(s):  
Thomas Senoner ◽  
Corinna Velik-Salchner ◽  
Helmuth Tauber

The pulmonary artery catheter (PAC) was introduced into clinical practice in the 1970s and was initially used to monitor patients with acute myocardial infarctions. The indications for using the PAC quickly expanded to critically ill patients in the intensive care unit as well as in the perioperative setting in patients undergoing major cardiac and noncardiac surgery. The utilization of the PAC is surrounded by multiple controversies, with literature claiming its benefits in the perioperative setting, and other publications showing no benefit. The right interpretation of the hemodynamic parameters measured by the PAC and its clinical implications are of the utmost essence in order to guide a specific therapy. Even though clinical trials have not shown a reduction in mortality with the use of the PAC, it still remains a valuable tool in a wide variety of clinical settings. In general, the right selection of the patient population (high-risk patients with or without hemodynamic instability undergoing high-risk procedures) as well as the right clinical setting (centers with experience and expertise) are essential in order for the patient to benefit most from PAC use.

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Hoon Choi ◽  
Joon Pyo Jeon ◽  
Jaewon Huh ◽  
Youme Kim ◽  
Wonjung Hwang

Abstract Background Pulmonary artery catheter insertion is a routine practice in high-risk patients undergoing cardiac surgery. However, pulmonary artery catheter insertion is associated with numerous complications that can be devastating to the patient. Incorrect placement is an overlooked complication with few case reports to date. Case presentation An 18-year-old male patient underwent elective mitral valve replacement due to severe mitral valve regurgitation. The patient had a history of synovial sarcoma, and Hickman catheter had been inserted in the right internal jugular vein for systemic chemotherapy. We made multiple attempts to position the pulmonary artery catheter in the correct position but failed. A chest radiography revealed that the pulmonary artery catheter was bent and pointed in the cephalad direction. Removal of the pulmonary artery catheter was successful, and the patient was discharged 10 days after the surgery without complications. Conclusions To prevent misplacement of the PAC, clinicians should be aware of multiple risk factors in difficult PAC placement, and be prepared to utilize adjunctive methods, such as TEE and fluoroscopy.


2015 ◽  
Vol 29 (1) ◽  
pp. 76-81 ◽  
Author(s):  
Yuting Chiang ◽  
Leila Hosseinian ◽  
Amanda Rhee ◽  
Shinobu Itagaki ◽  
Paul Cavallaro ◽  
...  

2020 ◽  
Vol 46 (08) ◽  
pp. 895-907
Author(s):  
Nina D. Anfinogenova ◽  
Oksana Y. Vasiltseva ◽  
Alexander V. Vrublevsky ◽  
Irina N. Vorozhtsova ◽  
Sergey V. Popov ◽  
...  

AbstractPrompt diagnosis of pulmonary embolism (PE) remains challenging, which often results in a delayed or inappropriate treatment of this life-threatening condition. Mobile thrombus in the right cardiac chambers is a neglected cause of PE. It poses an immediate risk to life and is associated with an unfavorable outcome and high mortality. Thrombus residing in the right atrial appendage (RAA) is an underestimated cause of PE, especially in patients with atrial fibrillation. This article reviews achievements and challenges of detection and management of the right atrial thrombus with emphasis on RAA thrombus. The capabilities of transthoracic and transesophageal echocardiography and advantages of three-dimensional and two-dimensional echocardiography are reviewed. Strengths of cardiac magnetic resonance imaging (CMR), computed tomography, and cardiac ventriculography are summarized. We suggest that a targeted search for RAA thrombus is necessary in high-risk patients with PE and atrial fibrillation using transesophageal echocardiography and/or CMR when available independently on the duration of the disease. High-risk patients may also benefit from transthoracic echocardiography with right parasternal approach. The examination of high-risk patients should involve compression ultrasonography of lower extremity veins along with the above-mentioned technologies. Algorithms for RAA thrombus risk assessment and protocols aimed at identification of patients with RAA thrombosis, who will potentially benefit from treatment, are warranted. The development of treatment protocols specific for the diverse populations of patients with right cardiac thrombosis is important.


2019 ◽  
Vol 152 (Supplement_1) ◽  
pp. S11-S12
Author(s):  
Katherine Turner ◽  
Tanya Harnish ◽  
Zahra Madani ◽  
Erin Kaleta ◽  
Christine Snozek

Abstract Cardiac troponin T (cTnT) assays are used for the diagnosis of acute myocardial infarctions and require serial measurements. Hemolysis is a common analytical interference for cTnT immunoassays, causing a false decrease in analyte concentration. Recollection of specimens that do not meet the recommended hemolysis threshold (H-index = 100) causes reporting delays and mistiming of serial measurements. This has been particularly disruptive to our emergency department and creates significant risk for patients whose diagnosis could be delayed by recollection due to hemolysis. Here we aimed to reevaluate the limits for acceptable hemolysis by determining the magnitude of cTnT concentration depression from hemolysis to evaluate whether more detailed thresholds could be established. To quantify the effects of hemolysis on cTnT, patient pools were prepared from residual serum with cTnT concentrations ranging from 10 to 100 ng/L and spiked with hemolysate prepared from lysed red blood cells to create H-indices ranging from 120 to 200. Samples were run in triplicate by the Elecsys Troponin T Gen. 5 STAT assay. Results demonstrated consistent percent decreases in cTnT across all concentrations tested for each level of hemolysis. The mean percent changes in cTnT concentrations in the presence of hemolysis for H-indices of 120, 140, 160, 180, and 200 were –3.4 ± 1.3%, –4.1 ± 1.2%, –6.3 ± 1.2%, –8.0 ± 1.7%, and –10.7 ± 1.22%, respectively. The observed decrease in cTnT was linearly related to the H index; predicted differences at higher H-indices (>200) agreed well with prior publications evaluating greater degrees of hemolysis. In our practice, a 2-hour delta ≥10 ng/L is considered significant for acute cardiac injury, <4 ng/L is a nonsignificant delta, and a delta of 4 to 9 ng/L is considered indeterminate. Baseline cTnT results of ≥100 ng/L result in immediate triage to cardiology. Approximately one-third of our patients with cTnT testing have baseline results within the reference range (≤15 ng/L males, ≤10 ng/L females). Based on the spiking data, H-index cutoffs were chosen to minimize recollections for low-risk and high-risk patients. Cutoffs for intermediate cTnT results were more restrictive to ensure delta interpretation would not change significantly. This resulted in a H-index of 300 for samples ≤8 ng/L, 200 for 9 to 40 ng/L, 160 for 41 to 70 ng/L, 140 for 71 to 99 ng/L, and 300 for ≥100 ng/L. These data quantify the percent change for cTnT in the presence of varying levels of hemolysis. At lower cTnT values, a larger degree of hemolysis can be tolerated because the percentage of depression results in a small absolute change, thus leading to less impact on the delta. The tiered H-index cutoffs allow minimal disruption to patient care for low- and high-risk patients, while maintaining the integrity of serial measurements for those with intermediate cTnT concentrations. Therefore, laboratories may consider releasing some hemolyzed cTnT specimens with a comment to decrease redraws and mistiming of serial measurements.


2020 ◽  
Vol 41 (4) ◽  
pp. 837-842
Author(s):  
Paulo Valderrama ◽  
Francisco Garay ◽  
Daniel Springmüller ◽  
Yeny Briones ◽  
Daniel Aguirre ◽  
...  

2019 ◽  
Vol 68 (01) ◽  
pp. 030-037 ◽  
Author(s):  
Antonia Schulz ◽  
Nicodème Sinzobahamvya ◽  
Mi-Young Cho ◽  
Wolfgang Böttcher ◽  
Oliver Miera ◽  
...  

Background This study reports midterm results of high-risk patients with hypoplastic left ventricle treated with initial bilateral pulmonary artery banding (PAB) before secondary Norwood procedure (NP). Methods Retrospective study of 17 patients admitted between July 2012 and February 2017 who underwent this treatment strategy because diagnosis or clinical status was associated with high risk for NP. Survival was compared with that of patients who underwent primary NP. Results Mean Aristotle comprehensive complexity score for NP would have been 19.7 ± 2.6. Risk factors included obstructed pulmonary venous return (n = 9), body weight < 2.5 kg (n = 7), total anomalous pulmonary venous connection (n = 3), and necrotizing enterocolitis (n = 1). Ten patients had a score ≥ 19.5. Early survival after PAB was 82.4% (14/17). NP was performed in 14 patients after improvement of clinical condition at a median age of 56 days and a weight ≥2,500 g. There was no 30-day mortality, but one interstage death. One patient died later after Glenn operation. One-year survival after primary PAB followed by NP was 70.6 ± 11.1%. During the same period, 35 patients with overall lower risk factors underwent primary NP; early postoperative survival and 1-year survival were 88.6 ± 5.4% and 68.6 ± 7.8%, respectively. There was no significant difference in survival between the two groups (p = 0.83) despite higher risk in the secondary Norwood group (p <0.0001). Conclusions PAB before NP in high-risk patients constituted salvage management. Primary PAB provided enough time for stabilization and control of most risk factors. It allowed midterm survival equivalent to the survival after primary NP in lower risk neonates.


Sensors ◽  
2020 ◽  
Vol 20 (10) ◽  
pp. 2902 ◽  
Author(s):  
Mehrdad Davoudi ◽  
Seyyed Mohammadreza Shokouhyan ◽  
Mohsen Abedi ◽  
Narges Meftahi ◽  
Atefeh Rahimi ◽  
...  

The successful clinical application of patient-specific personalized medicine for the management of low back patients remains elusive. This study aimed to classify chronic nonspecific low back pain (NSLBP) patients using our previously developed and validated wearable inertial sensor (SHARIF-HMIS) for the assessment of trunk kinematic parameters. One hundred NSLBP patients consented to perform repetitive flexural movements in five different planes of motion (PLM): 0° in the sagittal plane, as well as 15° and 30° lateral rotation to the right and left, respectively. They were divided into three subgroups based on the STarT Back Screening Tool. The sensor was placed on the trunk of each patient. An ANOVA mixed model was conducted on the maximum and average angular velocity, linear acceleration and maximum jerk, respectively. The effect of the three-way interaction of Subgroup by direction by PLM on the mean trunk acceleration was significant. Subgrouping by STarT had no main effect on the kinematic indices in the sagittal plane, although significant effects were observed in the asymmetric directions. A significant difference was also identified during pre-rotation in the transverse plane, where the velocity and acceleration decreased while the jerk increased with increasing asymmetry. The acceleration during trunk flexion was significantly higher than that during extension, in contrast to the velocity, which was higher in extension. A Linear Discriminant Analysis, utilized for classification purposes, demonstrated that 51% of the total performance classifying the three STarT subgroups (65% for high risk) occurred at a position of 15° of rotation to the right during extension. Greater discrimination (67%) was obtained in the classification of the high risk vs. low-medium risk. This study provided a smart “sensor-based” practical methodology for quantitatively assessing and classifying NSLBP patients in clinical settings. The outcomes may also be utilized by leveraging cost-effective inertial sensors, already available in today’s smartphones, as objective tools for various health applications towards personalized precision medicine.