scholarly journals LTspice Electro-Thermal Model of Joule Heating in High Density Polyethylene Optical Fiber Microducts

Electronics ◽  
2019 ◽  
Vol 8 (12) ◽  
pp. 1453 ◽  
Author(s):  
Shazad Akram ◽  
Kent Bertilsson ◽  
Johan Siden

At present, optical fiber microducts are joined together by mechanical type joints. Mechanical joints are bulky, require more space in multiple duct installations, and have poor water sealing capability. Optical fiber microducts are made of high-density polyethylene which is considered best for welding by remelting. Mechanical joints can be replaced with welded joints if the outer surface layer of the optical fiber microduct is remelted within one second and without thermal damage to the inner surface of the optical fiber duct. To fulfill these requirements, an electro-thermal model of Joule heat generation using a copper coil and heat propagation inside different layers of optical fiber microducts was developed and validated. The electro-thermal model is based on electro-thermal analogy that uses the electrical equivalent to thermal parameters. Depending upon the geometric shape and material properties of the high-density polyethylene, low-density polyethylene, and copper coil, the thermal resistance and thermal capacitance values were calculated and connected to the Cauer RC-ladder configuration. The power input to Joule heating coil and thermal convection resistance to surrounding air were also calculated and modelled. The calculated thermal model was then simulated in LTspice, and real measurements with 50 µm K-type thermocouples were conducted to check the validity of the model. Due to the non-linear transient thermal behavior of polyethylene and variations in the convection resistance values, the calculated thermal model was then optimized for best curve fitting. Optimizations were conducted for convection resistance and the power input model only. The calculated thermal parameters of the polyethylene layers were kept intact to preserve the thermal model to physical structure relationship. Simulation of the optimized electro-thermal model and actual measurements showed to be in good agreement.

Electronics ◽  
2021 ◽  
Vol 10 (6) ◽  
pp. 743
Author(s):  
Shazad Akram ◽  
Johan Sidén ◽  
Kent Bertilsson

Optical fiber microducts are joined together by mechanical joints. These mechanical joints are bulky, require more space per joint, and are prone to air pressure leakage and water seepage during service. A battery powered electrofusion welding system with a resistive-type joint has been recently developed to replace mechanical joints. These resistive-type electrofusion joints require physical connectors for power input. Due to a different installation environment, the power input connectors of resistive optical fiber microduct joints may corrode over time. This corrosion of connectors will eventually cause water seepage or air pressure leakage in the long run. Moreover, due to connector corrosion, resistive-type optical fiber microduct joints cannot be re-heated in future if the need arises. In this study, an inductively coupled electrofusion-type joint was proposed and investigated. This inductive-type electrofusion joint is not prone to long-term corrosion risk, due to the absence of power connectors. Inductive-type electrofusion joints can be re-heated again for resealing or removal in the long run, as no metal part is exposed to the environment. The battery powered inductive welding system can be easily powered with a 38 volts 160 watt-hour battery. The inductive-type electrofusion joint was welded within one second, and passed a 300-newton pull strength test and a 10-bar air pressure leakage test. It was demonstrated that the power input requirement for inductive electrofusion joints is 64% higher than that of resistive electrofusion joints. However, these inductive joints are relatively easy to manufacture, inexpensive, have no air leakage, and no water seepage risk in highly corrosive environments.


2003 ◽  
Vol 774 ◽  
Author(s):  
Susan M. Rea ◽  
Serena M. Best ◽  
William Bonfield

AbstractHAPEXTM (40 vol% hydroxyapatite in a high-density polyethylene matrix) and AWPEX (40 vol% apatite-wollastonite glass ceramic in a high density polyethylene matrix) are composites designed to provide bioactivity and to match the mechanical properties of human cortical bone. HAPEXTM has had clinical success in middle ear and orbital implants, and there is great potential for further orthopaedic applications of these materials. However, more detailed in vitro investigations must be performed to better understand the biological interactions of the composites and so the bioactivity of each material was assessed in this study. Specifically, the effects of controlled surface topography and ceramic filler composition on apatite layer formation in acellular simulated body fluid (SBF) with ion concentration similar to those of human blood plasma were examined. Samples were prepared as 1 cm × 1 cm × 1 mm tiles with polished, roughened, or parallel-grooved surface finishes, and were incubated in 20 ml of SBF at 36.5 °C for 1, 3, 7, or 14 days. The formation of a biologically active apatite layer on the composite surface after immersion was demonstrated by thin-film x-ray diffraction (TF-XRD), environmental scanning electron microscopy (ESEM) imaging and energy dispersive x-ray (EDX) analysis. Variations in sample weight and solution pH over the period of incubation were also recorded. Significant differences were found between the two materials tested, with greater bioactivity in AWPEX than HAPEXTM overall. Results also indicate that within each material the surface topography is highly important, with rougher samples correlated to earlier apatite formation.


Sign in / Sign up

Export Citation Format

Share Document