scholarly journals Secure Load Frequency Control of Smart Grids under Deception Attack: A Piecewise Delay Approach

Energies ◽  
2019 ◽  
Vol 12 (12) ◽  
pp. 2266 ◽  
Author(s):  
Fei Zhao ◽  
Jinsha Yuan ◽  
Ning Wang ◽  
Zhang Zhang ◽  
Helong Wen

The problem of secure load frequency control of smart grids is investigated in this paper. The networked data transmission within the smart grid is corrupted by stochastic deception attacks. First, a unified Load frequency control model is constructed to account for both network-induced effects and deception attacks. Second, with the Lyapunov functional method, a piecewise delay analysis is conducted to study the stability of the established model, which is of less conservativeness. Third, based on the stability analysis, a controller design method is provided in terms of linear matrix inequalities. Finally, a case study is carried out to demonstrate the derived results.

This paper present’s the study of Load Frequency Control (LFC) with certain nonlinear parameters at different communication delay latencies. The main aim is to maintain the stability of power system in all the adverse conditions including time delays in the network. Here, the stability of the system is demonstrated using Lyapuonav stability theorem in the presence of Delay’s and Linear Matrix Inequalities (LMI). Time delays are taken in the network. These delay latencies are linearized using the rational approximation method. Here Padé approximation is used with different time delay values. The problem is formulated using a decentralized LFC approach for a power system containing a single area. Simulation results carried out with different delay latency values integrated with the Load frequency control LMI and rigorous analysis is performed to test the robustness of the proposed strategy


Energies ◽  
2020 ◽  
Vol 13 (8) ◽  
pp. 2101
Author(s):  
Bi-Ying Chen ◽  
Xing-Chen Shangguan ◽  
Li Jin ◽  
Dan-Yun Li

This paper aims at developing a novel stability criterion to access the influence of the time-varying delay on the stability of power systems equipped with a proportional-integral (PI)-based load frequency control (LFC). The model of the LFC scheme considering time-varying communication delays is established at first. Then, an improved stability condition related to the information of delay bounds is deduced by constructing an augmented Lyapunov–Krasovski functional and using a matrix inequality, and it is expressed as linear matrix inequalities (LMIs) for easily checking. Finally, case studies for one-area and two-area LFC systems are carried out to show the relationship between delay margins ensuring the stability and the PI gains of the LFC, and also verify the superiority of proposed stability criterion compared with the previous ones.


Electronics ◽  
2020 ◽  
Vol 9 (4) ◽  
pp. 593
Author(s):  
Kun Yuan ◽  
Zhetong Ding ◽  
Yaping Li ◽  
Mingyu Huang ◽  
Kaifeng Zhang

Recently, demand-side resources (DSRs) have proceeded to participate in frequency control of the power systems. Compared with traditional generation-side resources, DSRs have unique intermittent characteristics. Taking aggregation of air conditions as an example, they must take a break after providing power support for a period of time considering the user comfort. This behavior, known as the intermittent characteristic, obviously affects the stability of the power systems. Therefore, this paper designs a corresponding controller for DSRs based on the intermittent control method. The designed controller is incorporated into the traditional load frequency control (LFC) system. The time delay is also considered. A rigorous stability proof and the robust H ∞ performance analysis is presented for the new LFC system. Then, the sufficient robust frequency stabilization result is presented in terms of linear matrix inequalities (LMIs). Finally, a two-area power system is provided to illustrate the obtained results. The results show that the designed intermittent controller can mitigate the impact of intermittent characteristics of DSRs.


2017 ◽  
Vol 137 (6) ◽  
pp. 834-844
Author(s):  
Ryo Hotchi ◽  
Kotaro Hashikura ◽  
Akira Kojima ◽  
Taisuke Masuta

Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1581
Author(s):  
Deepak Kumar Gupta ◽  
Amitkumar V. Jha ◽  
Bhargav Appasani ◽  
Avireni Srinivasulu ◽  
Nicu Bizon ◽  
...  

The automatic load frequency control for multi-area power systems has been a challenging task for power system engineers. The complexity of this task further increases with the incorporation of multiple sources of power generation. For multi-source power system, this paper presents a new heuristic-based hybrid optimization technique to achieve the objective of automatic load frequency control. In particular, the proposed optimization technique regulates the frequency deviation and the tie-line power in multi-source power system. The proposed optimization technique uses the main features of three different optimization techniques, namely, the Firefly Algorithm (FA), the Particle Swarm Optimization (PSO), and the Gravitational Search Algorithm (GSA). The proposed algorithm was used to tune the parameters of a Proportional Integral Derivative (PID) controller to achieve the automatic load frequency control of the multi-source power system. The integral time absolute error was used as the objective function. Moreover, the controller was also tuned to ensure that the tie-line power and the frequency of the multi-source power system were within the acceptable limits. A two-area power system was designed using MATLAB-Simulink tool, consisting of three types of power sources, viz., thermal power plant, hydro power plant, and gas-turbine power plant. The overall efficacy of the proposed algorithm was tested for two different case studies. In the first case study, both the areas were subjected to a load increment of 0.01 p.u. In the second case, the two areas were subjected to different load increments of 0.03 p.u and 0.02 p.u, respectively. Furthermore, the settling time and the peak overshoot were considered to measure the effect on the frequency deviation and on the tie-line response. For the first case study, the settling times for the frequency deviation in area-1, the frequency deviation in area-2, and the tie-line power flow were 8.5 s, 5.5 s, and 3.0 s, respectively. In comparison, these values were 8.7 s, 6.1 s, and 5.5 s, using PSO; 8.7 s, 7.2 s, and 6.5 s, using FA; and 9.0 s, 8.0 s, and 11.0 s using GSA. Similarly, for case study II, these values were: 5.5 s, 5.6 s, and 5.1 s, using the proposed algorithm; 6.2 s, 6.3 s, and 5.3 s, using PSO; 7.0 s, 6.5 s, and 10.0 s, using FA; and 8.5 s, 7.5 s, and 12.0 s, using GSA. Thus, the proposed algorithm performed better than the other techniques.


Sign in / Sign up

Export Citation Format

Share Document