scholarly journals Lightning Protection of the Explosion Airflow Arc-Quenching Gap for 110 kV Transmission Lines

Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 5126
Author(s):  
Dong Wu ◽  
Ju-feng Wang

With the increase in the voltage level and number of transmission lines, the probability of lightning strikes on transmission lines is significantly increased, while lightning breakage accidents occur frequently. Therefore, an explosion airflow arc-quenching gap for 110 kV transmission lines was developed based on the idea of rapid extinction. A mathematical model of the detonation wave based on the CJ (Chapman–Jouget) detonation wave theory was developed to calculate the detonation air pressure and analyze its influencing factors. ANSYS software and the magnetohydrodynamic (MHD) model were used to simulate the process of detonation airflow coupled with an arc, and the simulation results indicated that the power frequency arc was evidently suppressed with the influence of airflow, which can effectively prevent arcing. A combined impulse and power frequency test and arc-quenching tests were performed to verify the effectiveness of the arc-quenching gap. The results of the combined test indicated that the arc burn time was 0.1 ms and that no power frequency continuous current was displayed. The results ensured the accuracy of the simulation model. The results of the arc-quenching tests proved that the explosion airflow can extinguish a power frequency arc with an amplitude of 40 kA in half of a power frequency arc cycle.

Energies ◽  
2019 ◽  
Vol 12 (3) ◽  
pp. 445 ◽  
Author(s):  
Xianshan Guo ◽  
Ying Fu ◽  
Jingqiu Yu ◽  
Zheng Xu

The modeling of the Ultra-High Voltage (UHV) tower plays an important role in lightning protection analysis of transmission lines because the model used will directly affect the reliability of the results. Moreover, the higher the voltage level is, the more prominent the impact becomes. This paper first analyzes the inapplicability of the Hara multi-segment multi-surge impedance model for the ±1100 kV UHV towers, and then builds a non-uniform transmission line model of the tower. Secondly, the multi-segment multi-surge impedance model is used to study the influence of the tower’s spatial structure changes on its electromagnetic transient characteristics. It is concluded that the more accurately the nominal height of the tower is modeled, the more accurately its electromagnetic transient response is reflected. Finally, the lightning electromagnetic transient responses of the tower with the non-uniform transmission line model and with the multi-segment multi-surge impedance model are compared and analyzed, which shows that the non-uniform transmission line model is more in line with the actual situation under the lightning strikes.


2021 ◽  
Vol 2 (2) ◽  
pp. 36-43
Author(s):  
Evgeniy P. FIGURNOV ◽  
◽  
Yury I. ZHARKOV ◽  
Valeriy I. KHARCHEVNIKOV ◽  
◽  
...  

Methodology provided summarizes published, original and foreign theoretic and experimental data on the subject of heating and cooling of standard and shaped conductors of overhead power transmission line and uses those of them which are most affected to fundamental heat-transfer laws. Computation surface area of standard and shaped wire formulas are given. The common formula of convection heat transfer coefficient is provided, based on wind speed and direction, concerning antiicing mode. Parameters of this formula do not coincide with those existing, as they are based on experimental data on standard and shaped conductors but not on round tubes. Formula of computation of heat transfer power under the influence of solar radiation is given. Summarized formula of admissible continuous current computation is given, all the components have detailed description in the article.


2018 ◽  
Vol 197 ◽  
pp. 11001
Author(s):  
Aristo Adi Kusuma ◽  
Putu Agus Aditya Pramana ◽  
Brian Bramantyo S.D.A. Harsono ◽  
Buyung Sofiarto Munir

Based on Java-Bali grid disturbance data, the 66kV transmission lines that is close to or intersect with 150kV or 500kV transmission line is often experienced earth fault due to insulator flashover. The insulator flashover can be caused by indirect lightning strike since lightning strikes tend to strike higher structure. Therefore, this paper will determine the effect of indirect lightning strike on 150kV or 500kV transmission line to 66kV transmission line by modeling and simulation using application of transient analysis. Variation of lightning peak current magnitude and gap between 66kV transmission line and transmission line with higher voltage is performed during simulation. The range of peak current magnitude follows the data from lightning detection systems, while the value of gap follows the data from actual condition. It is found that higher current peak and closer gap will cause higher transient overvoltage on insulator of 66kV transmission line thus insulator flashover may occur more frequent. Addition of earth wire on 66kV transmission line and gap between each transmission by organizing the sag of conductor can be performed to minimize the insulator flashover.


2014 ◽  
Vol 29 (spe) ◽  
pp. 31-40 ◽  
Author(s):  
Ana Paula Paes dos Santos ◽  
José Ricardo Santos de Souza ◽  
Everaldo Barreiros de Souza ◽  
Alexandre de Melo Casseb do Carmo ◽  
Wanda Maria do Nascimento Ribeiro

Operational records of power outages of the electric energy distribution systems in eastern Amazonia presented a large number of events attributed to lightning strikes, during the 2006 to 2009 period. The regional electricity concessionary data were compared to actual lightning observations made by SIPAM's LDN system, over two areas where operational sub systems of transmission lines are installed. Statistical relations were drawn between the monthly lightning occurrence density and the number of power outages of the electric systems for both areas studied. The results showed that, although with some delays between these variables peaks, the number of power disruptions has a tendency to follow the behavior of the lightning occurrence densities variations. The numerical correlations were positive and may be useful to the transmission lines maintenance crews at least for the Belém-Castanhal electricity distribution sub system. Evidence was found, that the SST's over certain areas of the Pacific and Atlantic Oceans, influence convection over the area of interest, and may help to prognosticate the periods of intense electric storms, requiring repair readiness for the regional electric systems.


With rapid industrial and commercial growth and flourishing population, power demand is increasing rapidly. Modern methods of UHV transmission lines are important to transmit bulk amount of power more efficiently in comparison to earlier methods of transmission. 1200 KV UHV transmission line is India future and therefore forthcoming project to tackle this situation. However as line to line voltage level increases, complexity of the transmission line increases. But, with higher level of line to line voltage, complexity of transmission line increases. ROW is one of the major concerns with transmission lines. Many parameters need to take care in designing; one of them is a magnetic field distribution at surroundings of transmission line. India has initiated to expand its UHV range to 1200kv. Paper suggest magnetic field of three configurations of the 1200KV line. Horizontal and vertical configuration test lines have been installed. Analysis has been done by two methods finite element method and (Method of images) analytical method. FEM is used to solve partial differential equations. Results from both methods have been compared. 3D electric field analysis of configuration also performed. Plotted results are compared with ICNIRP standards and safety limits defined. Adverse effects of excess magnetic field is also discussed. Biological effects of electromagnetic field on people, animals and plants are also discussed. Thus paper aimed at magnetic field calculation and verification with respect to standard. It also helps to utilize less right of way. The subject is under broad development due to its advantages over lower voltage levels and holds significance in future as well.