scholarly journals Investigation of an Inclined Heat Pipe Heat Exchanger as a Passive Cooling Mechanism on a Photovoltaic Panel

Energies ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 7828
Author(s):  
Samiya Aamir Al-Mabsali ◽  
Jay Pillo Candido ◽  
Hassam Nasarullah Chaudhry ◽  
Mehreen Saleem Gul

An investigation on the heat transfer coefficient (HTC) of a heat pipe heat exchanger (HPHE) was carried out while being installed as a cooling mechanism on photovoltaic panels. The Ecohouse at the University of Technology and Applied Sciences in Muscat, Oman, was used as the case study. The experiment monitored the effect of temperature variations on PV-HPHE-induced power generation. The heat pipes were arranged in a double-sided condenser in a spanwise manner with spacing 50 mm in the center with an inclination angle of 3°. J-type thermocouples (exposed wire, polytetrafluoroethylene (PTFE) insulated) with a tip diameter of 1.5 mm were used. The results indicated mean values of HTC that were measured at 2.346 W/m2 K. The findings showed that the HTC values possessed a minimal standard error from the effect of variations of the ambient temperature. The mean HTC value of 2.346 W/m2 K can be used in the succeeding experiments using the same novel PV-HPHE setup. Additional results showed the recorded variations from the mean value of the HTC effect on the HPHE heat flow generation, which resulted in a 29% increase in power performance efficiency using PV-HPHE.

2019 ◽  
Author(s):  
Sakil Hossen ◽  
AKM M. Morshed ◽  
Amitav Tikadar ◽  
Azzam S. Salman ◽  
Titan C. Paul

2007 ◽  
Vol 2 (3) ◽  
pp. 86-95
Author(s):  
R. Sudhakaran ◽  
◽  
V. Sella Durai ◽  
T. Kannan ◽  
P.S. Sivasakthievel ◽  
...  

2004 ◽  
Vol 35 (2) ◽  
pp. 119-137 ◽  
Author(s):  
S.D. Gurney ◽  
D.S.L. Lawrence

Seasonal variations in the stable isotopic composition of snow and meltwater were investigated in a sub-arctic, mountainous, but non-glacial, catchment at Okstindan in northern Norway based on analyses of δ18O and δD. Samples were collected during four field periods (August 1998; April 1999; June 1999 and August 1999) at three sites lying on an altitudinal transect (740–970 m a.s.l.). Snowpack data display an increase in the mean values of δ18O (increasing from a mean value of −13.51 to −11.49‰ between April and August), as well as a decrease in variability through the melt period. Comparison with a regional meteoric water line indicates that the slope of the δ18O–δD line for the snowpacks decreases over the same period, dropping from 7.49 to approximately 6.2.This change points to the role of evaporation in snowpack ablation and is confirmed by the vertical profile of deuterium excess. Snowpack seepage data, although limited, also suggest reduced values of δD, as might be associated with local evaporation during meltwater generation. In general, meltwaters were depleted in δ18O relative to the source snowpack at the peak of the melt (June), but later in the year (August) the difference between the two was not statistically significant. The diurnal pattern of isotopic composition indicates that the most depleted meltwaters coincide with the peak in temperature and, hence, meltwater production.


Author(s):  
Yuko Komuro ◽  
Yuji Ohta

Conventionally, the strength of toe plantar flexion (STPF) is measured in a seated position, in which not only the target toe joints but also the knee and particularly ankle joints, are usually restrained. We have developed an approach for the measurement of STPF which does not involve restraint and considers the interactions of adjacent joints of the lower extremities. This study aimed to evaluate this new approach and comparing with the seated approach. A thin, light-weight, rigid plate was attached to the sole of the foot in order to immobilize the toe area. Participants were 13 healthy young women (mean age: 24 ± 4 years). For measurement of STPF with the new approach, participants were instructed to stand, raise the device-wearing leg slightly, plantar flex the ankle, and push the sensor sheet with the toes to exert STPF. The sensor sheet of the F-scan II system was inserted between the foot sole and the plate. For measurement with the seated approach, participants were instructed to sit and push the sensor with the toes. They were required to maintain the hip, knee, and ankle joints at 90°. The mean values of maximum STPF of the 13 participants obtained with each approach were compared. There was no significant difference in mean value of maximum STPF when the two approaches were compared (new: 59 ± 23 N, seated: 47 ± 33 N). The coefficient of variation of maximum STPF was smaller for data obtained with the new approach (new: 39%, seated: 70%). Our simple approach enables measurement of STPF without the need for the restraints that are required for the conventional seated approach. These results suggest that the new approach is a valid method for measurement of STPF.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 589
Author(s):  
Qilu Chen ◽  
Yutao Shi ◽  
Zhi Zhuang ◽  
Li Weng ◽  
Chengjun Xu ◽  
...  

Heat pipe heat exchangers (HPHEXs) are widely used in various industries. In this paper, a novel model of a liquid–liquid heat pipe heat exchanger in a countercurrent manner is established by considering the evaporation and condensation thermal resistances inside the heat pipes (HPs). The discrete method is added to the HPHEX model to determine the thermal resistances of the HPs and the temperature change trend of the heat transfer fluid in the HPHEX. The established model is verified by the HPHEX structure and experimental data in the existing literature and demonstrates numerical results that agree with the experimental data to within a 5% error. With the current model, the investigation compares the effectiveness and minimum vapor temperature of the HPHEX with three types of HP diameters, different mass flow rates, and different H* values. For HPs with a diameter of 36 mm, the effectiveness of each is improved by about 0.018 to 0.029 compared to HPs with a diameter of 28 mm. The results show that the current model can predict the temperature change trend of the HPHEX well; in addition, the effects of different structures on the effectiveness and minimum vapor temperature are obtained, which improve the performance of the HPHEX.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 1079.1-1079
Author(s):  
I. Yoshii

Background:Boolean remission criteria is one most popular and stringent criteria in treating patient with rheumatoid arthritis (RA), because it may guarantees a stable clinical course after attaining remission.Objectives:Impact of time span from initiation to achieving Boolean remission on maintaining disease activity, daily activities, and quality of life after attaining Boolean remission was investigated from daily clinical practice data.Methods:685 patients with RA since August 2010 under the T2T strategy were treated. They were monitored for their TJC, SJC, PGA, EGA, CRP, and disease activity indices such as CDAI, SDAI, DAS28, and Boolean criteria at every visit. HAQ-DI score, pain score using visual analog scale (PS-VAS), and EQ-5D were also monitored, and the quality of life score (QOLS) calculated from EQ-5D was determined at every visit from the time of diagnosis (baseline).Of 685 patients, 465 patients had achieved Boolean remission >1 times, and were consecutively followed up for >3 years. These patients were enrolled in the study. Time span from the first visit to first Boolean remission was calculated. The relationship between the time span and each of background parameters, and the relationship between the time span and each of the mean values of the SDAI score, HAQ score, PS-VAS, SHS, and QOLS at the first Boolean remission and thereafter was evaluated statistically.Patients were subsequently divided into the G ≤ 6 and G > 6 groups based on the achievement of first Boolean remission within two groups: time span G ≤ 6 months and G > 6 months. The two groups were compared with regard to the SDAI score, HAQ score, PS-VAS, SHS, and QOLS at first visit and at the time of first Boolean remission, and the mean values of these parameters after remission were evaluated statistically. Moreover, changes of these parameters and the mean Boolean remission rate after the first remission, and SDAI remission rate at the first Boolean remission to thereafter were compared between the two groups statistically.Results:Out of 465 patients, females comprised 343 (73.7%), and the mean age was 67.8 years (range, from 21–95 years). The mean disease duration at first visit was 6.1 years (range, from 1 months–45 years). The mean follow up length was 88.1 months (range: 36–122 months; median: 85 months) and mean time span from the first visit to the first Boolean remission was 8.1 months. The mean SDAI score, HAQ score, PS-VAS, and the QOLS at first visit were 13.3, 0.467, 33.2, and 0.834, respectively. Among the study parameters, PS-VAS and QOLS were significantly correlated with the time span. For parameters at the first Boolean remission, HAQ-DI score, PS-VAS, and QOLS demonstrated significant correlation with the time span, whereas SDAI, HAQ-DI score, PS-VAS, SHS, and QOLS after the Boolean remission demonstrated significant correlation with the time span.The comparison between the G ≤ 6 and the G > 6 groups revealed that the disease duration, HAQ score, and PS-VAS at baseline in the G > 6 were significantly higher than that in the G ≤ 6 group, and QOLS in the G ≤ 6 group was significantly higher than that in the G > 6 group at baseline. Similarly, the HAQ score and PS-VAS at the first Boolean remission in the G > 6 group were significantly higher than that in the G ≤ 6 group, whereas QOLS in the G ≤ 6 group demonstrated no significant difference compared with that in the G > 6 group.The mean value of the SDAI score after the first Boolean remission in the G > 6 group was significantly higher than that in the G ≤ 6 group. Similarly, the SDAI score, HAQ score, and PS-VAS after the first Boolean remission in the G > 6 group were also significantly higher than those in the G ≤ 6 group, and the mean value of the QOLS in the G ≤ 6 group were significantly higher than that in the G > 6 group. The Boolean remission rate and SDAI remission rate after the first Boolean remission were significantly higher in the G ≤ 6 group than those in the G > 6 group.Conclusion:Attaining Boolean remission ≤ 6 months for RA has significant benefit for more stable disease control, that leads good maintenance of ADL.Disclosure of Interests:None declared


Sign in / Sign up

Export Citation Format

Share Document