scholarly journals Development of a New Monoclonal Antibody against Brevetoxins in Oyster Samples Based on the Indirect Competitive Enzyme-Linked Immunosorbent Assay

Foods ◽  
2021 ◽  
Vol 10 (10) ◽  
pp. 2398
Author(s):  
Xiya Zhang ◽  
Mingyue Ding ◽  
Chensi Zhang ◽  
Yexuan Mao ◽  
Youyi Wang ◽  
...  

The consumption of shellfish contaminated with brevetoxins, a family of ladder-frame polyether toxins formed during blooms of the marine dinoflagellate Karenia brevis, can cause neurotoxic poisoning, leading to gastroenteritis and neurotoxic effects. To rapidly monitor brevetoxin levels in oysters, we generated a broad-spectrum antibody against brevetoxin 2 (PbTx-2), 1 (PbTx-1), and 3 (PbTx-3) and developed a rapid indirect competitive enzyme-linked immunosorbent assay (icELISA). PbTx-2 was reacted with carboxymethoxylamine hemihydrochloride (CMO) to generate a PbTx-2-CMO hapten and reacted with succinic anhydride (HS) to generate the PbTx-2-HS hapten. These haptens were conjugated to keyhole limpet hemocyanin (KLH) and bovine serum albumin (BSA) to prepare immunogen and coating antigen reagents, respectively, using the active ester method. After immunization and cell fusion, a broad-spectrum monoclonal antibody (mAb) termed mAb 1D3 was prepared. The 50% inhibitory concentration (IC50) values of the icELISA for PbTx-2, PbTx-1, and PbTx-3 were 60.71, 52.61, and 51.83 μg/kg, respectively. Based on the broad-spectrum mAb 1D3, an icELISA was developed to determine brevetoxin levels. Using this approach, the limit of detection (LOD) for brevetoxin was 124.22 μg/kg and recoveries ranged between 89.08% and 115.00%, with a coefficient of variation below 4.25% in oyster samples. These results suggest that our icELISA is a useful tool for the rapid monitoring of brevetoxins in oyster samples.

Planta Medica ◽  
2018 ◽  
Vol 84 (14) ◽  
pp. 1038-1044 ◽  
Author(s):  
Benyakan Pongkitwitoon ◽  
Seiichi Sakamoto ◽  
Rika Nagamitsu ◽  
Waraporn Putalun ◽  
Hiroyuki Tanaka ◽  
...  

AbstractHomoharringtonine (HHT), also known as omacetaxine, is a natural compound found in the genus Cephalotaxus and is a promising pharmaceutical drug used for the treatment of chronic or accelerated phase chronic myeloid leukemia. As a tool for the quantitative determination of HHT, a specific monoclonal antibody against HHT (MAb 6A1) was generated by conjugates prepared via sodium periodate-mediated oxidation. The developed indirect competitive enzyme-linked immunosorbent assay (icELISA) using MAb 6A1 was found to be highly specific and sensitive with a limit of detection for HHT of 48.8 ng/mL. Validation assays to evaluate precision and accuracy of the method were conducted by the use of intra- and inter-assay analysis, recovery test, and comparison analysis between the amounts of HHT determined by ELISA and high-performance liquid chromatography. These results revealed that the established icELISA using MAb 6A1 is specific, sensitive, and reliable enough to be applied to the qualitative analysis for HHT. Furthermore, the results of this study support the usefulness of sodium periodate as a reagent for the conjugation between Cephalotaxus alkaloids and proteins for producing specific antibodies.


1997 ◽  
Vol 78 (04) ◽  
pp. 1262-1267 ◽  
Author(s):  
Claudia C Folman ◽  
Albert E G K von dem Borne ◽  
Irma H J A M Rensink ◽  
Winald Gerritsen ◽  
C Ellen van der Schoot ◽  
...  

SummaryIn this report a sensitive enzyme-linked immunosorbent assay (ELISA) for the measurement of plasma thrombopoietin (Tpo) is described that is solely based on monoclonal antibodies (MoAbs).The assay has an intra and inter-assay variance of 5-7% and 7-13%, respectively. Native and recombinant human Tpo (rhTpo) were recognized equally well, no cross reactivity with other cytokines was found and rhTpo added to plasma and serum was completely recovered. With the ELISA, Tpo concentrations in EDTA-anticoagulated plasma of all controls (n = 193) could be determined, since the limit of detection (2 ± 0.8 A.U./ml, mean ± sd) was lower than the concentration found in controls (11 ± 8 A.U./ml, mean ± sd; 2.5th-97.5th percentile: 4-32 A.U./ml). Tpo levels in serum were on average 3.4 times higher than in plasma.We showed in vivo that Tpo is bound by platelets, as in thrombocytopenic patients (n = 5) a platelet transfusion immediately led to a drop in plasma Tpo level, whereas in patients receiving chemotherapy the induced thrombocytopenia was followed by a rise in plasma Tpo levels.In summary, these results indicate that this ELISA is a reliable tool for Tpo measurements and is applicable for large scale studies.


1997 ◽  
Vol 60 (8) ◽  
pp. 973-977 ◽  
Author(s):  
ANA I. HAZA ◽  
PALOMA MORALES ◽  
ROSARIO MARTÍIN ◽  
TERESA GARCÍIA ◽  
GONZALO ANGUITA ◽  
...  

A stable hybridoma cell line (B2B) has been produced that secretes a monoclonal antibody (MAb) specific for goat's milk αS2-casein. The MAb B2B was used in two enzyme-linked immunosorbent assay (ELISA) formats for the detection and quantification of the presence of goat's milk in ewe's milk. In the indirect ELISA format the limit of detection was 0.5 to 15% (vol/vol) substitution of goat's milk for ewe's milk. Afterwards, a competitive indirect ELISA was successfully developed for the detection of 0.25 to 15% (vol/vol) of goat's milk in ewe's milk. This competitive indirect ELISA is a very sensitive assay; it can be performed in less than 5 h and is not influenced by the heat treatment of milk.


2015 ◽  
Vol 72 (10) ◽  
pp. 1682-1691 ◽  
Author(s):  
Kun Zeng ◽  
Yanmin Zou ◽  
Jianxia Liu ◽  
Wei Wei ◽  
Meng Zhang ◽  
...  

A sensitive, competitive indirect enzyme-linked immunosorbent assay (ELISA) was developed for the detection of triclocarban (TCC) in waters and sediments. Haptens were synthesized by derivatizing the paraposition of a phenyl moiety of TCC. The synthesized hapten was then coupled to bovine thyroglobulin to be used as an immunogen, based on which, a high affinity monoclonal antibody 4D5 was produced with the hybridoma technique. Under the optimized conditions, using the monoclonal antibody, excellent performances of the assay were obtained: satisfactory sensitivity (IC50 (50% inhibition concentration) value, 0.43 ng/mL; limit of detection, 0.05 ng/mL); good linear range (0.05–10 ng/mL); and satisfactory accuracy (recoveries 70.7–107% in waters; 74.8–98.3% in sediments). Furthermore, TCC was found with the concentration ranging from not detected to 422.12 ng/L in waters and from 6.68 ng/g to 78.67 ng/g in sediments in Yunliang River, Ancient Canal and Hongqiao Port in Zhenjiang City. In conclusion ELISA could be applied for monitoring TCC in aquatic environments.


Molecules ◽  
2021 ◽  
Vol 26 (14) ◽  
pp. 4243
Author(s):  
Yong Xie ◽  
Yarong Wang ◽  
Xueling Yan ◽  
Lu Gan ◽  
Tao Le

To monitor the illegal used of furaltadone, a highly sensitive indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) and fluorescence-linked immunosorbent assay (FLISA) based on a monoclonal antibody (mAb) were developed for the detection of 3-amino-5-methylmorpholino-2-oxazolidinone (AMOZ), the major metabolite of furaltadone in animal tissues. The highly specific mAb, which was very sensitive to a nitrophenyl derivative of AMOZ (2-NP-AMOZ) with IC50 values of 0.11 and 0.09 ng/mL for ic-ELISA and FLISA, respectively, was selected for the development of immunoassays. For both the ic-ELISA and FLISA for AMOZ-spiked experiments, acceptable recovery rates of 81.1–105.3% and coefficients of variation of 4.7–9.8% were obtained. In addition, results from both ic-ELISA and FLISA methods for spiked samples’ data showed excellent correlation coefficients ranging from 0.9652 to 0.9927. Meanwhile, the proposed ic-ELISA and FLISA for thirty spiked samples were confirmed by standard LC-MS/MS with high correlation coefficients of 0.9911 and 0.9921, respectively. These results suggest that the developed ic-ELISA and FLISA are valid and cost-effective tools for high-throughput monitoring methods for AMOZ residues in animal tissues.


2013 ◽  
Vol 2013 ◽  
pp. 1-4 ◽  
Author(s):  
Yanfei Wang ◽  
Mingqiang Zou ◽  
Yi Han ◽  
Fan Zhang ◽  
Jinfeng Li ◽  
...  

With the monoclonal antibody against kanamycin being prepared successfully, a bead-based indirect competitive fluorescent immunoassay was developed to detect kanamycin in milk. The fact that there was no significant cross-reaction with other aminoglycoside antibiotics implied that the monoclonal antibody was highly specific for kanamycin. The limit of detection (LOD) and the 50% inhibition concentration (IC50) in raw milk were 3.2 ng/mL and 52.5 ng/mL, respectively. Using the method developed in this study, the kanamycin concentrations were monitored in raw milk after the intramuscular administration of kanamycin in sick cows. Compared to the conventional enzyme-linked immunosorbent assay (ELISA), the method using the suspension array system was more sensitive. The results obtained in the present study showed a good correlation with that of the ELISA.


Sign in / Sign up

Export Citation Format

Share Document