scholarly journals Effect of Rotation and Hole Arrangement in Cold Bridge-Type Impingement Cooling Systems

Author(s):  
Lorenzo Cocchi ◽  
Alessio Picchi ◽  
Bruno Facchini

Experimental activity has been performed to study different impingement cooling schemes in static and rotating conditions. Geometry replicates a leading-edge cold bridge system, including a radial supply channel and five rows of film-cooling and showerhead holes. Two impingement geometries have been studied, with different numbers of holes and diameters but with equal overall passage area. Reynolds numbers up to 13,800 and rotation numbers up to 0.002 have been investigated (based on an equivalent slot width). Tests have been performed using a novel implementation of transient heat transfer technique, which allows correct replication of the sign of buoyancy forces by flowing ambient temperature air into a preheated test article. Results show that complex interactions occur between the different features of the system, with a particularly strong effect of jet supply condition. Rotation further interacts with these phenomena, generally leading to a slight decrease in heat transfer.

Author(s):  
Carol E. Bryant ◽  
Connor J. Wiese ◽  
James L. Rutledge ◽  
Marc D. Polanka

Gas turbine hot gas path components are protected through a combination of internal cooling and external film cooling. The coolant typically travels through internal passageways, which may involve impingement on the internal surface of a turbine component, before being ejected as film cooling. Internal cooling effects have been studied in facilities that allow measurement of heat transfer coefficients within models of the internal cooling paths, with large heat transfer coefficients generally desirable. External film cooling is typically evaluated through measurements of the adiabatic effectiveness and its effect on the external heat transfer coefficient. Efforts aimed at improving cooling are often focused on either only the internal cooling or the film cooling; however, the common coolant flow means the internal and external cooling schemes are linked and the coolant holes themselves provide another convective path for heat transfer to the coolant. Recently, measurements of overall cooling effectiveness using matched Biot number turbine component models allow evaluation of the nondimensional wall temperature achieved for the fully cooled component. However, the relative contributions of internal cooling, external cooling, and convection within the film cooling holes is not well understood. Large scale, matched Biot number experiments, complemented by CFD simulations, were performed on a fully film cooled cylindrical leading edge model to evaluate the effects of various alterations in the cooling design on the overall effectiveness. The relative influence of film cooling and cooling within the holes was evaluated by selectively disabling individual holes and quantifying how the overall effectiveness changed. Several internal impingement cooling schemes in addition to a baseline case without impingement cooling were also tested. In general, impingement cooling is shown to have a negligible influence on the overall effectiveness in the showerhead region. This indicates that the cost and pressure drop penalties for implementing impingement cooling may not be compensated by an increase in thermal performance. Instead, the internal cooling provided by convection within the holes themselves was shown, along with external film cooling, to be a dominant contribution to the overall cooling effectiveness. Indeed, the numerous holes within the showerhead region impede the ability of internal surface cooling schemes to influence the outside surface temperature. The results of this research may allow improved focus of future efforts on the forms of cooling with the greatest potential to improve cooling performance.


2020 ◽  
Vol 142 (4) ◽  
Author(s):  
Simone Paccati ◽  
Lorenzo Cocchi ◽  
Lorenzo Mazzei ◽  
Antonio Andreini

Abstract This work presents the results of a numerical analysis performed on a gas turbine leading edge cooling system. The investigation was carried out in order to provide a detailed interpretation of the outcomes of a parallel experimental campaign. The cooling geometry consists of a cold bridge-type impingement system: a radial channel feeds an array of holes, which in turn generate impingement jets cooling down the inner side of the leading edge surface. Coolant is extracted by five rows of holes, replicating film cooling and showerhead systems. Two impingement geometries were considered, presenting different holes arrangements and diameters but sharing the same overall passage area, in order to highlight the effect of different coolant distributions inside the leading edge cavity. For both geometries, a single test point was investigated in static and rotating conditions, with an equivalent slot Reynolds number of around 8200 and feeding conditions corresponding to the midspan radial section of the blade. Both steady Reynolds averaged Navier Stokes (RANS) approach and scale adaptive simulation (SAS) were tested. Due to the strong unsteadiness of the flow field, the latter proved to be superior: as a consequence, the SAS approach was adopted to study every case. A fairly good agreement was observed between the measured and computed heat transfer distributions, which allowed to exploit the numerical results to get a detailed description of the phenomena associated with the different cases. Results reveal that the two holes arrangements lead to strongly different heat transfer patterns, related to the specific flow phenomena occurring inside the leading edge cavity and to the mutual influence of the various system features. Rotational effects also appear to interact with the supply condition, altering the jet lateral spreading and the overall heat transfer performance.


Author(s):  
Thomas E. Dyson ◽  
David G. Bogard ◽  
Sean D. Bradshaw

Computational simulations using RANS and the k-ω SST turbulence model were performed to complement experimental measurements of overall cooling effectiveness and adiabatic film effectiveness for a film cooled turbine vane airfoil. Particular attention was placed on the showerhead. The design made use of five rows of showerhead holes and a single gill row on both pressure and suction sides. The simulated geometry also included the internal impingement cooling configuration. Internal and external boundary conditions were matched to experiments using the same vane model. To correctly simulate conjugate heat transfer effects, the experimental vane model was constructed to match the Biot number for engine conditions. Computational predictions of the overall and adiabatic effectiveness were compared to experimental measurements from both the conducting vane and a model constructed from low conductivity foam. The results show that the k-ω SST RANS model over-predicts both adiabatic and overall effectiveness due in part to limited jet diffusion. The simulations were also used to investigate heat transfer augmentation, which is difficult to measure experimentally in the showerhead region. The results showed substantial augmentation of 1.5 or more over large portions of the leading edge, with many areas exceeding 2.0. However, the simulations also showed a reduction in heat transfer (i.e., hf/h0 < 1) for locations beneath the coolant jets. This result was likely due to Taw being an inappropriate driving temperature for separated jets.


Author(s):  
Scott R. Nowlin ◽  
David R. H. Gillespie ◽  
Peter T. Ireland ◽  
Ralf Knoche ◽  
T. Robert Kingston

In this paper, the authors develop a novel method of obtaining regionally-averaged heat transfer coefficients in flowfields characterized by three temperatures using the well-known transient calorimeter technique. The technique is used to determine heat transfer in aluminum models of idealized turbine blade leading edges cooled through internal surface impingement, film cooling feed passages, and external convective film cooling. The external surface is subject to a stagnating mainstream crossflow. Importantly, the contributions to heating from the external flow and cooling from the internal flow can be separately resolved solely by heating the internal flow. Results for a basic showerhead geometry and an advanced intersecting-passage cooling configuration are presented for a range of internal and external Reynolds numbers. The intersecting-passage model shows little improvement in heat transfer coefficient over the showerhead for the flow conditions tested; however, the total cooling carried out is improved by the increase in exposed surface area. The technique’s uncertainties are fully assessed.


Author(s):  
Luca Andrei ◽  
Carlo Carcasci ◽  
Riccardo Da Soghe ◽  
Bruno Facchini ◽  
Francesco Maiuolo ◽  
...  

An experimental survey on a state of the art leading edge cooling scheme was performed to evaluate heat transfer coefficients (HTC) on a large scale test facility simulating an high pressure turbine airfoil leading edge cavity. Test section includes a trapezoidal supply channel with three large racetrack impingement holes. On the internal surface of the leading edge, four big fins are placed in order to confine impingement jets. The coolant flow impacts the leading edge internal surface and it is extracted from the leading edge cavity through 24 showerhead holes and 24 film cooling holes. The aim of the present study is to investigate the combined effects of jet impingement and mass flow extraction on the internal heat transfer of the leading edge. A non uniform mass flow extraction was also imposed to reproduce the effects of pressure side and suction side external pressure. Measurements were performed by means of a transient technique using narrow band Thermo-chromic Liquid Crystals (TLC). Jet Reynolds number and crossflow conditions into the supply channel were varied in order to cover the typical engine conditions of these cooling systems (Rej = 10000–40000). Experiments were compared with a numerical analysis on the same test case in order to better understand flow interaction inside the cavity. Results are reported in terms of detailed 2D maps, radial-wise and span-wise averaged values of Nusselt number.


2013 ◽  
Vol 135 (3) ◽  
Author(s):  
Luca Andrei ◽  
Carlo Carcasci ◽  
Riccardo Da Soghe ◽  
Bruno Facchini ◽  
Francesco Maiuolo ◽  
...  

An experimental survey on a state of the art leading edge cooling scheme was performed to evaluate heat transfer coefficients (HTC) on a large scale test facility simulating a high pressure turbine airfoil leading edge cavity. The test section includes a trapezoidal supply channel with three large racetrack impingement holes. On the internal surface of the leading edge, four big fins are placed in order to confine impingement jets. The coolant flow impacts the leading edge internal surface, and it is extracted from the leading edge cavity through 24 showerhead holes and 24 film cooling holes. The aim of the present study is to investigate the combined effects of jet impingement and mass flow extraction on the internal heat transfer of the leading edge. A nonuniform mass flow extraction was also imposed to reproduce the effects of the pressure side and suction side external pressure. Measurements were performed by means of a transient technique using narrow band thermochromic liquid crystals (TLCs). Jet Reynolds number and crossflow conditions into the supply channel were varied in order to cover the typical engine conditions of these cooling systems (Rej=10,000-40,000). Experiments were compared with a numerical analysis on the same test case in order to better understand flow interaction inside the cavity. Results are reported in terms of detailed 2D maps, radial-wise, and span-wise averaged values of Nusselt number.


Author(s):  
S. Paccati ◽  
L. Cocchi ◽  
L. Mazzei ◽  
A. Andreini

Abstract This work presents the results of a numerical analysis performed on a gas turbine leading edge cooling system. The investigation was carried out in order to provide a detailed interpretation of the outcomes of a parallel experimental campaign. The cooling geometry consists of a cold bridge type impingement system: a radial channel feeds an array of holes, which in turn generate impingement jets cooling down the inner side of the leading edge surface. Coolant is extracted by five rows of holes, replicating film cooling and showerhead systems. Two impingement geometries were considered, presenting different holes arrangements and diameters but sharing the same overall passage area, in order to highlight the effect of different coolant distributions inside the leading edge cavity. For both geometries a single test point was investigated in static and rotating conditions, with an equivalent slot Reynolds number of around 8200 and feeding conditions corresponding to the midspan radial section of the blade. Both steady RANS approach and Scale Adaptive Simulation (SAS) were tested. Due to the strong unsteadiness of the flow field, the latter proved to be superior: as a consequence, SAS approach was adopted to study every case. A fairly good agreement was observed between the measured and computed heat transfer distributions, which allowed to exploit the numerical results to get a detailed description of the phenomena associated with the different cases. Results reveal that the two holes arrangements lead to strongly different heat transfer patterns, related to the specific flow phenomena occurring inside the leading edge cavity and to the mutual influence of the various system features. Rotational effects also appear to interact with the supply condition, altering the jet lateral spreading and the overall heat transfer performance.


Author(s):  
Szu-Chi Huang ◽  
Yao-Hsien Liu

Heat transfer in a leading edge, triangular shaped cooling channel with three channel orientations under high rotation numbers is experimentally studied. Continuous ribs and V-shaped ribs, both at 45° rib angle of attack, are applied on the leading and trailing surfaces. For each rib case, three channel orientations (90°, 67.5°, and 45°) with respect to the plane of rotation are tested. The rib height to hydraulic diameter ratio (e/Dh) is 0.085 and the rib pitch to height ratio (P/e) is 9. Reynolds numbers are from 15000 to 25000, and the rotation numbers are from 0 to 0.65. Results show that the heat transfer variation is influenced by the combined effects of rib configuration and channel orientation. Effect of channel orientation influences local heat transfer distribution inside this triangular channel, and heat transfer is enhanced gradually on the leading surface when the channel orientation varies from 90° to 45° for both ribbed cases in this study.


1999 ◽  
Vol 121 (3) ◽  
pp. 558-568 ◽  
Author(s):  
M. B. Kang ◽  
A. Kohli ◽  
K. A. Thole

The leading edge region of a first-stage stator vane experiences high heat transfer rates, especially near the endwall, making it very important to get a better understanding of the formation of the leading edge vortex. In order to improve numerical predictions of the complex endwall flow, benchmark quality experimental data are required. To this purpose, this study documents the endwall heat transfer and static pressure coefficient distribution of a modern stator vane for two different exit Reynolds numbers (Reex = 6 × 105 and 1.2 × 106). In addition, laser-Doppler velocimeter measurements of all three components of the mean and fluctuating velocities are presented for a plane in the leading edge region. Results indicate that the endwall heat transfer, pressure distribution, and flowfield characteristics change with Reynolds number. The endwall pressure distributions show that lower pressure coefficients occur at higher Reynolds numbers due to secondary flows. The stronger secondary flows cause enhanced heat transfer near the trailing edge of the vane at the higher Reynolds number. On the other hand, the mean velocity, turbulent kinetic energy, and vorticity results indicate that leading edge vortex is stronger and more turbulent at the lower Reynolds number. The Reynolds number also has an effect on the location of the separation point, which moves closer to the stator vane at lower Reynolds numbers.


Author(s):  
Shang-Feng Yang ◽  
Je-Chin Han ◽  
Salam Azad ◽  
Ching-Pang Lee

This paper experimentally investigates the effect of rotation on heat transfer in typical turbine blade serpentine coolant passage with ribbed walls at low Mach numbers. To achieve the low Mach number (around 0.01) condition, pressurized Freon R-134a vapor is utilized as the working fluid. The flow in the first passage is radial outward, after the 180 deg tip turn the flow is radial inward to the second passage, and after the 180 deg hub turn the flow is radial outward to the third passage. The effects of rotation on the heat transfer coefficients were investigated at rotation numbers up to 0.6 and Reynolds numbers from 30,000 to 70,000. Heat transfer coefficients were measured using the thermocouples-copper-plate-heater regional average method. Heat transfer results are obtained over a wide range of Reynolds numbers and rotation numbers. An increase in heat transfer rates due to rotation is observed in radially outward passes; a reduction in heat transfer rate is observed in the radially inward pass. Regional heat transfer coefficients are correlated with Reynolds numbers for nonrotation and with rotation numbers for rotating condition, respectively. The results can be useful for understanding real rotor blade coolant passage heat transfer under low Mach number, medium–high Reynolds number, and high rotation number conditions.