scholarly journals Experimental Performance of a Two-Phase Ejector: Nozzle Geometry and Subcooling Effects

Inventions ◽  
2020 ◽  
Vol 5 (2) ◽  
pp. 23
Author(s):  
Khaled Ameur ◽  
Zine Aidoun ◽  
Mehdi Falsafioon

This paper presents the results of an experimental study on a two-phase ejector. The main objective is to assess the effects of the nozzle’s divergent and the throat diameter on performance under various working conditions. Under the same conditions, ejector operation with a convergent nozzle, results in higher critical primary mass flow rate and lower critical pressure than with a convergent-divergent nozzle version. Experiments show as well that the flow expansion is higher in the convergent-divergent nozzle. The throat diameter turns out to have an important impact only on the amount of the critical mass flow rate. The nozzle geometry has no impact on its optimal position in the ejector. Globally, the ejector with the convergent-divergent nozzle provides a higher entrainment ratio, due to a reduced primary mass flow rate and an increased secondary flow induction. Tests also show that the ejector with a lower throat diameter provides a higher entrainment ratio, due to better suction with less primary flow. Unlike the convergent-divergent nozzle, the convergent nozzle permits an entrainment ratio almost insensitive to a wide range of primary inlet sub-cooling levels. Primary and secondary mass flow rates increase proportionally with the subcooling level and result in a quasi-constant entrainment ratio.

Author(s):  
Jiarui Zhang ◽  
Zhixun Xia ◽  
Liya Huang ◽  
Likun Ma

To predict engine performance and further instruct the integral engine design, a more reasonable and accurate numerical model of the two-phase underwater ramjet was introduced in this article by considering the bubble formation process. Two-fluid model was used to examine the bubbly flow in the nozzle and its mathematical model was solved by a fourth-order Runge–Kutta method. Subsequently, the influences of vessel velocity, gas mass flow rate, navigational depth, and orifice diameter of the bubble injector on the performance of the engine were discussed. Results show that, compared with convergent nozzle, Laval nozzle is proved to improve the thrust of the engine, especially at relatively high velocity and gas mass flow rate. With the other conditions fixed, there is an optimum vessel velocity for the ramjet, in which maximum thrust is generated. And a smaller orifice diameter always promotes the engine performance, while this promotion is negligible when the orifice diameter is smaller than 1 mm. Besides, increasing backpressure will cause serious performance drop, which means that the the two-phase underwater ramjet is only efficient for shallow depths.


2017 ◽  
Vol 25 (04) ◽  
pp. 1730004 ◽  
Author(s):  
Mehdi Rasti ◽  
Ji Hwan Jeong

Capillary tubes are widely used as expansion devices in small-capacity refrigeration systems. Since the refrigerant flow through the capillary tubes is complex, many researchers presented empirical dimensionless correlations to predict the refrigerant mass flow rate. A comprehensive review of the dimensionless correlations for the prediction of refrigerants mass flow rate through straight and coiled capillary tubes depending on their geometry and adiabatic or diabatic capillary tubes depending on the flow configurations has been discussed. A comprehensive review shows that most of previous dimensionless correlations have problems such as discontinuity at the saturated lines or ability to predict the refrigerant mass flow rate only for the capillary tube subcooled inlet condition. The correlations suggested by Rasti et al. and Rasti and Jeong appeared to be general and continuous and these correlations can be used to predict the refrigerant mass flow rate through all the types of capillary tubes with wide range of capillary tube inlet conditions including subcooled liquid, two-phase mixture, and superheated vapor conditions.


1998 ◽  
Vol 120 (3) ◽  
pp. 605-612 ◽  
Author(s):  
I. G. Hassan ◽  
H. M. Soliman ◽  
G. E. Sims ◽  
J. E. Kowalski

Experimental data are presented for the mass flow rate and quality of two-phase (air-water) discharge through a small branch (6.35 mm i.d.) located on the side of a large reservoir under stratified conditions. These data correspond to different values of the interface level between the onsets of gas and liquid entrainments for test-section pressures ranging from 316 to 517 kPa, test-section-to-separator pressure differences ranging from 40 to 235 kPa, and different hydraulic resistances of the line connecting the test section and separator. Influences of these independent variables on the mass flow rate and quality are discussed and normalized plots are presented showing that the data can be collapsed for a wide range of conditions. Comparisons are made with previous investigations and new empirical correlations are formulated and shown to be capable of predicting the present data with good accuracy.


2010 ◽  
Vol 132 (4) ◽  
Author(s):  
Yoon Jo Kim ◽  
Yogendra K. Joshi ◽  
Andrei G. Fedorov ◽  
Young-Joon Lee ◽  
Sung-Kyu Lim

It is now widely recognized that the three-dimensional (3D) system integration is a key enabling technology to achieve the performance needs of future microprocessor integrated circuits (ICs). To provide modular thermal management in 3D-stacked ICs, the interlayer microfluidic cooling scheme is adopted and analyzed in this study focusing on a single cooling layer performance. The effects of cooling mode (single-phase versus phase-change) and stack/layer geometry on thermal management performance are quantitatively analyzed, and implications on the through-silicon-via scaling and electrical interconnect congestion are discussed. Also, the thermal and hydraulic performance of several two-phase refrigerants is discussed in comparison with single-phase cooling. The results show that the large internal pressure and the pumping pressure drop are significant limiting factors, along with significant mass flow rate maldistribution due to the presence of hot-spots. Nevertheless, two-phase cooling using R123 and R245ca refrigerants yields superior performance to single-phase cooling for the hot-spot fluxes approaching ∼300 W/cm2. In general, a hybrid cooling scheme with a dedicated approach to the hot-spot thermal management should greatly improve the two-phase cooling system performance and reliability by enabling a cooling-load-matched thermal design and by suppressing the mass flow rate maldistribution within the cooling layer.


2005 ◽  
Vol 127 (5) ◽  
pp. 1029-1037 ◽  
Author(s):  
L. O. Schunk ◽  
G. F. Nellis ◽  
J. M. Pfotenhauer

Growing interest in larger scale pulse tubes has focused attention on optimizing their thermodynamic efficiency. For Stirling-type pulse tubes, the performance is governed by the phase difference between the pressure and mass flow, a characteristic that can be conveniently adjusted through the use of inertance tubes. In this paper we present a model in which the inertance tube is divided into a large number of increments; each increment is represented by a resistance, compliance, and inertance. This model can include local variations along the inertance tube and is capable of predicting pressure, mass flow rate, and the phase between these quantities at any location in the inertance tube as well as in the attached reservoir. The model is verified through careful comparison with those quantities that can be easily and reliably measured; these include the pressure variations along the length of the inertance tube and the mass flow rate into the reservoir. These experimental quantities are shown to be in good agreement with the model’s predictions over a wide range of operating conditions. Design charts are subsequently generated using the model and are presented for various operating conditions in order to facilitate the design of inertance tubes for pulse tube refrigerators. These design charts enable the pulse tube designer to select an inertance tube geometry that achieves a desired phase shift for a given level of acoustic power.


2018 ◽  
Vol 8 (9) ◽  
pp. 1413 ◽  
Author(s):  
Dan Yao ◽  
Kwongi Lee ◽  
Minho Ha ◽  
Cheolung Cheong ◽  
Inhiug Lee

A new pump, called the hybrid airlift-jet pump, is developed by reinforcing the advantages and minimizing the demerits of airlift and jet pumps. First, a basic design of the hybrid airlift-jet pump is schematically presented. Subsequently, its performance characteristics are numerically investigated by varying the operating conditions of the airlift and jet parts in the hybrid pump. The compressible unsteady Reynolds-averaged Navier-Stokes equations, combined with the homogeneous mixture model for multiphase flow, are used as the governing equations for the two-phase flow in the hybrid pump. The pressure-based methods combined with the Pressure-Implicit with Splitting of Operators (PISO) algorithm are used as the computational fluid dynamics techniques. The validity of the present numerical methods is confirmed by comparing the predicted mass flow rate with the measured ones. In total, 18 simulation cases that are designed to represent the various operating conditions of the hybrid pump are investigated: eight of these cases belong to the operating conditions of only the jet part with different air and water inlet boundary conditions, and the remaining ten cases belong to the operating conditions of both the airlift and jet parts with different air and water inlet boundary conditions. The mass flow rate and the efficiency are compared for each case. For further investigation into the detailed flow characteristics, the pressure and velocity distributions of the mixture in a primary pipe are compared. Furthermore, a periodic fluctuation of the water flow in the mass flow rate is found and analyzed. Our results show that the performance of the jet or airlift pump can be enhanced by combining the operating principles of two pumps into the hybrid airlift-jet pump, newly proposed in the present study.


Author(s):  
Nan Liang ◽  
Changqing Tian ◽  
Shuangquan Shao

As one kind of fluid machinery related to the two-phase flow, the refrigeration system encounters more problems of instability. It is essential to ensure the stability of the refrigeration systems for the operation and efficiency. This paper presents the experimental investigation on the static and dynamic instability in an evaporator of refrigeration system. The static instability experiments showed that the oscillatory period and swing of the mixture-vapor transition point by observation with a camera through the transparent quartz glass tube at the outlet of the evaporator. The pressure drop versus mass flow rate curves of refrigerant two phase flow in the evaporator were obtained with a negative slope region in addition to two positive slope regions, thus making the flow rate a multi-valued function of the pressure drop. For dynamic instabilities in the evaporation process, three types of oscillations (density wave type, pressure drop type and thermal type) were observed at different mass flow rates and heat fluxes, which can be represented in the pressure drop versus mass flow rate curves. For the dynamic instabilities, density wave oscillations happen when the heat flux is high with the constant mass flow rate. Thermal oscillations happen when the heat flux is correspondingly low with constant mass flow rate. Though the refrigeration system do not have special tank, the accumulator and receiver provide enough compressible volume to induce the pressure drop oscillations. The representation and characteristic of each oscillation type were also analyzed in the paper.


Sign in / Sign up

Export Citation Format

Share Document