scholarly journals Interobserver Agreement and Plane-Dependent Intraobserver Variability of Shear Wave Sonoelastography in the Differential Diagnosis of Ectopic Thymus Tissue

2021 ◽  
Vol 10 (2) ◽  
pp. 214
Author(s):  
Zbigniew Adamczewski ◽  
Magdalena Stasiak ◽  
Bartłomiej Stasiak ◽  
Magdalena Adamczewska ◽  
Andrzej Lewiński

Shear wave elastography (SWE) has been demonstrated to be a useful tool in the differential diagnosis of ectopic thymus tissues (ETs), providing quantitative values of the shear wave stiffness (SWS) of both ETs and adjacent thyroid tissue. However, no data are available on the potential influence of the imaging plane (transverse vs. longitudinal) on the obtained SWS and shear wave ratio (SWR) values in SWE of these tissues. Moreover, no reports on the interobserver repeatability of SWE were published in regard to ETs. The aim of this study has been to evaluate the potential influence of the examination plane—transverse vs. longitudinal—on the SWS and SWR results, as well as to determine whether SWE of ETs is subjected to interobserver variability. SWE was demonstrated to have high inter- and intraobserver agreement in the evaluation of ETs and adjacent thyroid tissue. Significant differences between SWS values, but not SWR values, obtained in the transverse and longitudinal planes were observed. This phenomenon is probably a result of anisotropy-related artifacts and does not reduce the reliability of the method. SWE operators should be aware of the presence of plane-dependent artifacts to properly interpret the obtained results.

2020 ◽  
Vol 9 (12) ◽  
pp. 3816 ◽  
Author(s):  
Magdalena Stasiak ◽  
Zbigniew Adamczewski ◽  
Renata Stawerska ◽  
Bartłomiej Stasiak ◽  
Andrzej Lewiński

The ultrasound (US) pattern of intrathyroidal ectopic thymus (IET) can resemble papillary thyroid carcinoma (PTC) while the extrathyroidal ectopic thymus (EET) can mimic pathological lymph nodes. Recently, the usefulness of strain elastography (SE) was demonstrated in the differential diagnosis, however this method has several limitations. The aim of the current study was to assess the usefulness of shear wave elastography (SWE) in this field. The US, SE, and SWE were performed in 31 children with 53 ectopic thymuses (ETs) and quantitative values of SWE parameters were calculated, so as to generate potential normative values of ET elasticity and of the shear wave ratio (SWR). The mean SWRIET was 0.89 ± 0.21 and the mean shear wave stiffness (SWS) was 7.47 ± 1.93 kPa. The mean SWREET was 0.84 ± 0.15 and the mean SWSEET was 11.28 ± 2.58 kPa. The results have proven that the stiffness of ETs is lower or equal to the thyroid’s. SWE was demonstrated to be a useful diagnostic method for ET evaluation. Therefore, the application of SWE in ET diagnosis allows more accurate evaluation of ET-like lesions and, in many cases, allows one to avoid invasive procedures, simultaneously providing a precise monitoring method based on combined US and SWE evaluation.


2019 ◽  
Vol 8 (4) ◽  
pp. 37-44 ◽  
Author(s):  
E. V. Kovaleva ◽  
T. Yu. Danzanova ◽  
G. T. Sinyukova ◽  
P. I. Lepedatu ◽  
E. A. Gudilina ◽  
...  

In this article, based on two clinical examples, the possibilities of multiparametric ultrasound in the differential diagnosis of metastatic and lymphoproliferative changes in lymph nodes in primary-multiple malignant tumors, including breast cancer and lym - phoma, are evaluated. Multiparameteric ultrasound includes B-mode, color and energy Doppler imaging, strain elastography, shear wave elastography and contrast-enhanced ultrasound (CEUS). Standardization and reproducibility of these ultrasound techniques will allow to objectify the study, obtaining specific indicators of shear wave velocity in the zones of interest and specific signs of contrast enhancement, which can be used as impor tant differential diagnostic tool in oncology.


2018 ◽  
Vol 70 (3) ◽  
pp. 347-354 ◽  
Author(s):  
Shui-Qing Liu ◽  
Yan-Ping Liu ◽  
Bang-Guo Zhou ◽  
Xiao-Hong Deng ◽  
Xiao-Long Li ◽  
...  

2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Ioana Golu ◽  
Ioan Sporea ◽  
Lavinia Moleriu ◽  
Anca Tudor ◽  
Marioara Cornianu ◽  
...  

Background and Aims. 2D-shear wave elastography (2D-SWE) is a relatively new elastographic technique. The aim of the present study is to determine the values of the elasticity indexes (EI) measured by 2D-SWE in parathyroid benign lesions (adenomas or hyperplasia) and to establish if this investigation is helpful for the preoperative identification of the parathyroid adenoma. Material and Methods. The study groups were represented by 22 patients with primary or tertiary hyperparathyroidism, diagnosed by specific tests, and 43 healthy controls, in whom the thyroid parenchyma was evaluated, in order to compare the EI of the thyroid tissue with those of the parathyroid lesions. Results. The mean EI measured by 2D-SWE in the parathyroid lesions was 10.2 ± 4.9 kPa, significantly lower than that of the normal thyroid parenchyma (19.5 ± 7.6 kPa; p=0.007), indicating soft tissue. For a cutoff value of 12.5 kPa, the EI assessed by 2D-SWE had a sensitivity of 93% and a specificity of 86% (AUC = 0.949; p<0.001) for predicting parathyroid lesions. Conclusion. A value lower than 12.5 kPa for the mean EI measured by 2D-SWE can be used to confirm that the lesion/nodule is a parathyroid adenoma.


2019 ◽  
Vol 9 (2) ◽  
pp. 334-338
Author(s):  
Qing Yang ◽  
Wenhong Zhou ◽  
Jiyu Li ◽  
Guojun Wu ◽  
Feng Ding ◽  
...  

Objective: To compare the diagnostic value of shear wave elastography (SWE) and real-time elastography (RTE) in the diagnosis of benign and malignant thyroid nodules. Methods: A total of 34 patients who ever received thyroidectomy in our hospital from January 2016 to January 2018 were identified. Meanwhile, all the patients received SWE and RTE before surgery, and all the diagnoses were confirmed by pathological examinations. With respect to SWE technique, the Subject Operating Characteristics (ROC) curves were drawn, in order to obtain the optimal threshold and then make differential diagnoses of benign and malignant thyroid nodules. In terms of RTE, the Rago 5 scoring method was utilized to make differential diagnoses of benign and malignant thyroid nodules. Besides, the pathological examinations after surgery could be considered as the golden standard. At last, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of SWE and RTE were calculated, respectively. Results: A total of 51 thyroid nodules were identified, and 41 nodules were benign, 10 nodules were malignant. On the basis of ROC curves, with respect to SWE, the best threshold for differential diagnosis of benign and malignant thyroid nodules is 38.3 kPa. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of SWE were 72.7% (8/11), 85% (34/40), 82.4% (42/51), 68.4% (13/19), and 87.5% (35/40), respectively. And the diagnostic indicators of RTE were 81.8% (9/11), 87.5% (35/40), 84.3% (43/51), 73.7% (14/19), and 90.0% (36/40). The sensitivity of quasi-static elastography in differential diagnosis of benign and malignant thyroid nodules with diameter ≤1 cm was 87.5% (7/8), and the sensitivity of SWE was 50.0% (5/10). In addition, the accuracy of SWE in differential diagnosis of benign and malignant thyroid nodules with diameter ≥3 cm was 100% (6/6), and the accuracy of RTE for this kind of thyroid nodules was 66.7% (4/6). Conclusion: Both SWE and RTE technology have good application value in differential diagnosis of benign and malignant thyroid nodules. But, SWE is preferable when making diagnosis of benign and malignant thyroid nodules with diameter ≥3 cm, and RTE was superior in detecting benign and malignant thyroid nodules with diameter ≤1 cm.


Sign in / Sign up

Export Citation Format

Share Document