scholarly journals Strengths and Weaknesses of Light Transmission Aggregometry in Diagnosing Hereditary Platelet Function Disorders

2020 ◽  
Vol 9 (3) ◽  
pp. 763 ◽  
Author(s):  
Marie-Christine Alessi ◽  
Pierre Sié ◽  
Bernard Payrastre

Hereditary defects in platelet function are responsible for sometimes severe mucocutaneous hemorrhages. They are a heterogeneous group of abnormalities whose first-line diagnosis typically involves interpreting the results of in vitro light transmission aggregometry (LTA) traces. Interpretation of LTA is challenging. LTA is usually performed in specialized laboratories with expertise in platelet pathophysiology. This review updates knowledge on LTA, describing the various platelet aggregation profiles typical of hereditary platelet disorders to guide the physician in the diagnosis of functional platelet disorders.

2019 ◽  
Vol 119 (07) ◽  
pp. 1154-1161 ◽  
Author(s):  
Karina Althaus ◽  
Barbara Zieger ◽  
Tamam Bakchoul ◽  
Kerstin Jurk ◽  

AbstractSeveral in vitro platelet function tests are available for the diagnosis of inherited platelet function disorders. Currently, the light transmission aggregometry (LTA) is recommended as one of the first-step tests. LTA is available in most specialized hemostasis laboratories. Although the LTA is accepted as a ‘gold standard’ assay for the evaluation of platelet function, its standardization in the clinical practice is still challenging. The GTH-based THROMKID-Plus Study Group has performed an inter-laboratory trial in Germany and Austria. Five different agonists were selected according to the Scientific and Standardization Committee/International Society on Thrombosis and Haemostasis recommendations and shipped in 3 different sets (one should represent a healthy control and two should simulate platelet function disorders) to 15 specialized laboratories in Germany and Austria. Agonists were analyzed by APACT or PAP4/8 aggregometer using platelet-rich plasma from healthy donors. In addition, laboratory-internal platelet agonists were tested in platelet-rich plasma from a healthy donor. All laboratories (9 used APACT, 6 used PAP4/PAP8) showed very consistent data regarding the maximum percentage of aggregation induced by the tested agonists and identified the differential diagnosis of the simulated platelet function disorders with one exception, which was due to technical problems. In contrast, there was a high variability of the laboratory-internal inductors regarding reagent type, concentrations and pathological cut-off values. Our study showed that the shipment of agonists is suitable for an inter-laboratory survey of LTA. However, there is still a remarkable need for standardization of agonist reagents and their concentration as well as for definition of reference ranges.


2017 ◽  
Vol 24 (6) ◽  
pp. 914-919 ◽  
Author(s):  
Frantisek Nehaj ◽  
Juraj Sokol ◽  
Jela Ivankova ◽  
Michal Mokan ◽  
Frantisek Kovar ◽  
...  

The availability of direct oral anticoagulants has caused a paradigm shift in the management of thrombosis. Rivaroxaban and apixaban are 2 direct oral anticoagulants whose target specificity is activated factor X (FXa). However, it is still not fully understood if and how xabans impact platelet function. This observational study aimed to assess the in vitro platelet function in patients with atrial fibrillation receiving xabans. This was a single-center study quantifying platelet aggregation in 41 patients treated with apixaban or rivaroxaban by light transmission aggregometry. The thrombin receptor activating peptide (TRAP)-induced platelet aggregation was significantly lower 2 hours after taking rivaroxaban or apixaban compared to baseline value (56.15% [8.53%] vs 29.51% [12.9%]; P = .000). Moreover, concomitant use of angiotensin-converting enzyme blockers, proton pump inhibitors, and statins reduces the efficiency of xabans. The TRAP-induced platelet aggregation was reduced in patients with cardiovascular disease 2 hours after receiving xabans.


2008 ◽  
Vol 99 (01) ◽  
pp. 121-126 ◽  
Author(s):  
Siegmund Braun ◽  
Stefan Jawansky ◽  
Wolfgang Vogt ◽  
Julinda Mehilli ◽  
Albert Schömig ◽  
...  

SummaryThe level of platelet aggregation, measured with light transmission aggregometry (LTA) in platelet rich plasma (PRP), has been shown to predict outcomes after percutaneous coronary intervention (PCI). However, measuring parameters of platelet function with LTA is time consuming and weakly standardized. Thus, a fast and standardized method to assess platelet function after clopidogrel treatment would be of great value for clinical practice. A new method, multiple electrode platelet aggregometry (MEA), to rapidly measure platelet aggregation in whole blood has recently been developed. The aim of this study was to assess parameters of platelet function with MEA and LTA before and after administration of 600 mg clopidogrel. Blood samples from 149 patients scheduled for coronary angiography were taken after clopidogrel treatment; in addition, in 60 of the patients samples were available before clopidogrel treatment. ADP-induced platelet aggregation was measured with LTA and simultaneously in whole blood with MEA on the Multiplate analyzer. Platelet aggregation measured with MEA decreased significantly after clopidogrel treatment (P<0.0001). ADP-induced platelet aggregation assessed with MEA and LTA correlated significantly (Spearman rank correlation coefficient=0.71; P<0.0001).The results of MEA, a fast and standardized method to assess the platelet response to ADP prior to and after clopidogrel treatment, correlate well with LTA.


2020 ◽  
Vol 40 (S 01) ◽  
pp. S21-S25
Author(s):  
K. Althaus ◽  
M. Wagner ◽  
I. Marini ◽  
T. Bakchoul ◽  
L. Pelzl

Abstract Introduction The diagnosis of platelet function disorder in children is challenging. Light transmission aggregometry is the gold standard for platelet function disorders. However, large blood volumes are required. Currently, there are no existing tools for the diagnosis of platelet function disorders that use small blood volumes. AKT signaling plays a central role in platelet activation during hemostasis and might be visualized by flow cytometry. Methods Platelet-rich plasma obtained by centrifugation of citrated blood from healthy volunteers was activated with arachidonic acid, thrombin receptor activating peptide-6 (TRAP-6), collagen, adenosine diphosphate ADP, collagen-related peptide (CRP), and epinephrine. After platelet activation, the phosphorylation of AKT was assessed by flow cytometer using a Navios cytometer. Results Healthy volunteers showed a reproducible phosphorylation of AKT upon activation. In comparison to nonactivated platelets, we documented an increase in pAKT expression with all agonists. Especially TRAP-6 and CRP caused considerable increase in percentage of pAKT expression throughout all the tested healthy volunteers. Conclusion An activation of the AKT-signal pathway by different agonists can clearly be detected on the flow cytometer, indicating that the visualization of signaling in platelets by flow cytometry might be an efficient alternative for light transmission aggregometry to test platelet function in children.


Blood ◽  
2011 ◽  
Vol 118 (21) ◽  
pp. 5266-5266 ◽  
Author(s):  
Celine Desconclois ◽  
Vincent Valarche ◽  
Tewfik Boutekedjiret ◽  
Martine Raphael ◽  
Marie Dreyfus ◽  
...  

Abstract Abstract 5266 Diagnosis and characterization of platelet function disorders may be challenging. It requires multiple laboratory data including the assessment of platelet functions. Platelet function analysis is most commonly performed using light transmission aggregometry (LTA). LTA is a time-consuming method requiring centrifugation steps and large blood volumes. It is difficult to perform in children and in cases of thrombocytopenia. In contrast, platelet aggregation in whole blood using impedancemetry (WBI) is a fast method, allows omission of centrifugation steps and performance of platelet function studies under more physiological conditions with small samples size. It is based on the change of resistance proportional to the amount of platelets sticking to two electrodes where an alternating current is applied. Multiplate® (for “multiple electrode aggregometry”, Dynabite Medical) is a new generation of WBI aggregometer using diluted blood and single-use test cells containing twin electrodes that reduce the variation of results. We have already showed the good Multiplate® performance concerning ristocetin-induced platelet aggregation in a population of 30 patients with characterized von Willebrand disease (Valarche et al, 2011). Our aim in this ongoing study was to assess the performance of WBI in patients with inherited platelet function disorders. We tested 8 patients including 2 unrelated patients with Glanzmann Thrombasthenia (GT), 2 unrelated patients with Bernard-Soulier Syndrome (BSS), 1 patient with Gray Platelet Syndrome (GPS) and 3 patients from the same family with a platelet type von Willebrand disease (PTVWD). GT, BSS, and PTVWD diagnosis were confirmed using genotyping. BSS and GPS patients had chronic thrombocytopenia. GT, BSS, GPS and 1/3 PTVWD had platelet function tests with LTA in parallel. WBI was performed on heparinized whole blood diluted at ½ in NaCl at 37°C and triggered using high (0.77 mg/mL, WBI RH) and low (0.5 mg/mL, WBI RL) final ristocetin concentrations, ADP (6.5 Âμ Mol, WBI ADP) and collagen (3.2 Âμg/mL, WBI Coll). Results were expressed in arbitrary unit (AU) corresponding to the area under the aggregation curve observed during 6 min. Normal ranges indicated in brackets were based on the mean +/− 2 SD of 30 healthy volunteers' results. Results highlighted in grey are those out of the normal ranges (Table 1).Table 1:Results of the 8 patients with inherited platelet disorders.PatientsPlatelet count (109/L)WBI RH (AU) [>500]WBI RL (AU) [<150]WBI ADP (AU) [>550]WBI Coll (AU) [>500]GT 116923441443GT 224955417ND7BSS 134371119129BSS 230254733582GPS7916217ND42PTVWD22099493ND338PTVWD231116560ND1092PTVWD2341174168ND852 All patients except those with PTVWD had decreased results with WBI. However, as expected, patients with GT had flat traces using WBI ADP and WBI Coll but normal or only decreased curves (234 – 554 AU) using WBI RH. On the opposite, BSS patients had flat traces using WBI RH but detectable curves using WBI ADP (191 – 335 AU) despite decreased platelet count. The thrombocytopenic GPS patient has a flat trace using WBI Coll and decreased WBI RH (162 AU). Members of the PTVWD family had normal results except a slightly increased result with WBI RH in 1/3 patients. Finally, LTA results performed in 6/8 patients were all in accordance with those of the WBI. In conclusion, in 8 patients with well characterized inherited platelet disorders, WBI was able to detect all abnormalities except PTVWD. In such cases, different ristocetin concentrations use might be critical to increase sensitivity. In our hands, WBI was able to discriminate disorders involving platelet glycoprotein (GP) IIb-IIIa from GP Ib-IX-V: GT patients exhibited flat traces using WBI ADP and WBI Coll, whereas patients with BSS exhibited flat traces with ristocetin. These preliminary results need to be confirmed on a larger population of patients with various characterized platelet function disorders. They suggest that WBI using the Multiplate® analyzer, which is a fast, easy and blood-preserving test, could be a valuable extra step before or in addition to the classic LTA for the diagnosis of severe inherited platelet disorders. Disclosures: No relevant conflicts of interest to declare.


2019 ◽  
Vol 25 ◽  
pp. 107602961985840 ◽  
Author(s):  
Yigit Sener ◽  
Mufide Okay ◽  
Seda Aydin ◽  
Yahya Buyukasik ◽  
Filiz Akbiyik ◽  
...  

Bleeding has been reported in patients with chronic myeloid leukemia (CML) using tyrosine kinase inhibitors (TKIs). In this study, we aimed to evaluate platelet functions and associated bleeding symptoms in patients with CML using TKIs. A standardized questionnaire that was developed for inherited bleeding disorders (ISTH/SSC Bleeding Assessment Tool) was used to score bleeding symptoms in 68 chronic phase patients with CML receiving imatinib (n = 47), dasatinib (n = 15), or nilotinib (n = 6). Light transmission aggregometry was used for platelet function testing. None of the patients had major bleeding (score > 3). Minor bleeding was observed in 25.6% and 20% of the patients in imatinib and dasatinib treatment groups. Impaired/decreased platelet aggregation was observed in 29.8% of imatinib treatment group, 50% of nilotinib group, and 40% of dasatinib group. A secondary aggregation abnormality compatible with the release defect was observed in 26% of patients with CML; 25.5%, 33.3%, and 16.7% of patients receiving imatinib, dasatinib, and nilotinib, respectively. No correlation was found between bleeding symptoms and the impaired platelet function. We can conclude that TKIs may impair in vitro platelet aggregation but this impairment is not associated with bleeding diathesis.


2009 ◽  
Vol 147 (5) ◽  
pp. 729-736 ◽  
Author(s):  
Teresa Quiroga ◽  
Manuela Goycoolea ◽  
Valeria Matus ◽  
Pamela Zúñiga ◽  
Carlos Martínez ◽  
...  