scholarly journals Mac-2 Binding Protein Glycosylation Isomer for Screening High-Risk Esophageal Varices in Liver Cirrhotic Patient

Livers ◽  
2021 ◽  
Vol 1 (2) ◽  
pp. 60-67
Author(s):  
Saut Horas H. Nababan ◽  
Kemal Fariz Kalista ◽  
Chyntia O.M. Jasirwan ◽  
Juferdy Kurniawan ◽  
Cosmas Rinaldi A. Lesmana ◽  
...  

Background: Esophageal varices occur at middle to advanced stages of cirrhosis and are associated with increased mortality due to their potential for rupture and bleeding. The aim of this study is to examine the accuracy of a surrogate marker, Mac-2 binding protein glycosylation isomer (M2BPGi), for screening high-risk esophageal varices in cirrhotic patients. Methods: Ninety-four cirrhotic patients who underwent endoscopy screening at Cipto Mangunkusumo Hospital, Jakarta, Indonesia were included. Patients with a history of ligation, portal vein thrombosis, or hepatocellular carcinoma were excluded. All enrolled patients underwent ultrasonography, transient elastography, and laboratory tests. The HISCL-5000 Sysmex analyzer was used to measure M2BPGi levels. Results: Of these 94 patients, 27 had high-risk esophageal varices and 67 had non-high-risk esophageal varices. M2BPGi levels were higher in patients with high-risk esophageal varices compared with those with non-high-risk esophageal varices (cutoff index (COI) of 11.4 vs. 3.7, p < 0.001). The sensitivity, specificity, positive predictive value, and negative predictive value of M2BPGi with a cutoff value of 5 COI was 92.6%, 70.1%, 55.6%, and 95.9%, respectively. Conclusions: M2BPGi could be used as a non-invasive surrogate marker for ruling out high-risk esophageal varices in cirrhotic patients. This method is cheap and non-invasive and could be used as a screening tool in resource-limited settings.

2020 ◽  
pp. 1-2
Author(s):  
Revathy Marimuthu Shanmugam ◽  
Vinay C ◽  
Sathya Gopalasamy ◽  
Chitra Shanmugam

BACKGROUND: Many noninvasive surrogate marker for Portal hypertension or for the presence or grade of esophageal varices were studied..Splenomegaly along with splenic congestion secondary to splenic hyperdynamic circulation is seen secondary to Portal hypertension in cirrhotic patients that can be quantified by elastography. AIM:The aim of this study was to investigate whether spleen stiffness, assessed by TE, useful tool for grading chronic liver diseases and to compare its performance in predicting the presence and size of esophageal varices in liver cirrhosis patients. METHODOLOGY:86 patients with cirrhosis and 80 controls underwent transient elastography of liver and spleen for the assessment of liver stiffness (LSM) and spleen stiffness (SSM) . Upper GI endoscopy done in all Cirrhotic patients. RESULTS: Spleen stiffness showed higher values in liver cirrhosis patients as compared with controls: 58.2 kpa vs14.8 kpa (P < 0.0001) and also found to be significantly higher in cirrhotic patients compared with varices and those without varices (69.01 vs 42.05 kpa, P < 0.0001). Liver stiffness was also found to be higher in cirrhotic patients with varices when compared to patients without varices (38.5vs 21.2 kpa). Using both liver and spleen stiffness measurement we can predicted the presence of esophageal varices correctly. CONCLUSION: Spleen stiffness can be assessed using transient elastography, higher value correlated well with liver cirrhosis and presence of esophageal varices although it couldn’t correlate with grade of Esophageal Varix. Combined assessment of spleen and liver stiffness had better prediction of presence of Esophageal Varix.


Author(s):  
Naglaa El-Toukhy Ramadan El-Toukhy ◽  
Sharaf Elsayed Ali Hassanien ◽  
Ramy A. Metwaly ◽  
Medhat A. Khalil ◽  
Badawy A. Abdulaziz

Background and Study Aims: Portal hypertension is one of the most important complications of liver cirrhosis. The prevalence of varices among cirrhotic patients is variable. Therefore, endoscopic screening of all patients with liver cirrhosis would result in a large number of unnecessary additional burdens to endoscopic units. Our aim was to assess the diagnostic accuracy of spleen stiffness measured by transient elastography (Fibroscan) for prediction of the presence of varices in patients with hepatitis C related cirrhosis. Patients and Methods: The study was carried out on 100 patients with HCV-induced cirrhosis and were divided into 2 groups according to presence or absence of varices by Esophago-gastro-duodenoscopy: Group I: patients with HCV-induced cirrhosis with varices; Group II: patients with HCV-induced cirrhosis without varices. Clinical and laboratory parameters, andominal ultrasonography, Upper gastrointestinal endoscopy and transient elastography to assess the liver and spleen stiffness were carried out to all studied persons. Results: Spleen stiffness had significant diagnostic value to differentiate between cirrhotic patients with varices and cirrhotic patients without varices , it had significant diagnostic value in presence of esophageal varices at cut-off (≥46.4 K Pascal) the sensitivity for detection of esophageal varices was 93%, specificity 100%, positive predictive value (PPV) was 80%, negative predictive value (NPV) was 100%; accuracy was 95% and area under the curve was 0.98 denoting that spleen stiffness is a good predictor of esophageal varices. Conclusion: Spleen stiffness was considered as an excellent predictor of esophageal varices and better than liver stiffness in prediction of esophageal varices presence and had significant diagnostic value to differentiate between the patients with varices and patients without varices at cut off (≥46.4 K Pascal) and it may have a role in variceal grading.


2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
José Ricardo Borém Lopes ◽  
Alexandre Rodrigues Ferreira ◽  
Priscila Menezes Ferri Liu ◽  
Thaís Costa Nascentes Queiroz ◽  
Eleonora Druve Tavares Fagundes ◽  
...  

2009 ◽  
Vol 8 (4) ◽  
pp. 325-330 ◽  
Author(s):  
Francisco Barrera ◽  
Arnoldo Riquelme ◽  
Alejandro Soza ◽  
Álvaro Contreras ◽  
Gerty Barrios ◽  
...  

2015 ◽  
Vol 17 (1) ◽  
pp. 5 ◽  
Author(s):  
Adriana Bintintan ◽  
Romeo Ioan Chira ◽  
Vasile Virgil Bintintan ◽  
Georgiana Nagy ◽  
Roberta Maria Manzat-Saplacan ◽  
...  

Aims: Non-invasive methods are required to diagnose presence and grading of esophageal varices in patients with he- patic cirrhosis and in this respect we have evaluated the role of transient elastography and abdominal ultrasound parameters. Material and methods: Cirrhotic patients were prospectively evaluated by transient elastography and Doppler ultrasound for diagnosis of presence and grading of esophageal varices, the results being compared with the findings of the esophagogas- troduodenoscopy. Results: Sixty patients with hepatic cirrhosis were analysed. The parameters that reached statistical signifi- cance for diagnosis of esophageal varices were: liver stiffness (LSM) > 15 kPa, hemodynamic liver index (PVr1) ≥ 0.66, portal vascular resistance (PVR) > 17.66 and splenoportal index (SPI) > 4.77. The only parameter that reached statistical power for the diagnosis of large esophageal varices was LSM at a cut-off value of 28.8 kPa. Conclusions: Assessment of LSM in patients with liver cirrhosis can predict both the presence of esophageal varices and of large esophageal varices. The PVr1, PVR and SPI Doppler indexes can be used to diagnose the presence of esophageal varices but have no role in the prediction of large esophageal varices. Further studies are required to confirm these results and offer a stronger clinical significance.


2014 ◽  
Vol 155 (7) ◽  
pp. 270-276 ◽  
Author(s):  
Gabriella Pár ◽  
Andrea Trosits ◽  
Ferenc Pakodi ◽  
Imre Szabó ◽  
József Czimmer ◽  
...  

Introduction: One of the most serious complications of liver cirrhosis is variceal bleeding. Early recognition of the oesophageal varices is of primary importance in the prevention of variceal bleeding. Endoscopy is the only means to directly visualize varices and measure their size, as one of the most important predictor of the risk of bleeding. During the course of cirrhosis repeated oesophago-gastro-bulboscopic examinations are recommended. As these interventions are expensive and often poorly accepted by patients who may refuse further follow-up, there is a need for non-invasive methods to predict the progression of portal hypertension as well as the presence and the size of oesophageal varices. After several combinations of biological and ultrasonographical parameters proposed for the detection of advanced fibrosis, it was suggested that liver stiffness measured by transient elastography, a novel non-invasive technology may reflect not only fibrosis and portal pressure but it may even predict the presence or absence of large oesophageal varices in patients with cirrhosis. Aim: The aim of the authors was to study the diagnostic accuracy of transient elastography using FibroScan for selecting patients who are at risk of bearing large (Paquet-grade ≥ II) oesophageal varices and high risk of bleeding. Method: The authors performed upper tract endoscopy and transient elastography in 74 patients with chronic liver disease (27 patients with chronic hepatitis and 47 patients with liver cirrhosis). The relationships between the presence of oesophageal varices (Paquet-grade 0–IV) and liver stiffness (kPa), as well as the hematological and biochemical laboratory parameters (prothrombine international normalized ratio, platelet count, aspartate aminotransferase, alanine aminotransferase, albumin, and aspartate aminotransferase/platelet ratio index) were investigated. The predictive role of liver stiffness for screening patients with varices and those who are at high risk of variceal bleeding was also analysed. Results: Liver stiffness values significantly correlated with the grade of oesophageal varices (Paquet-grade) (r = 0.67, p<0.0001). The liver stiffness value of 19.2 kPa was highly predictive for the presence of oesophageal varices (AUROC: 0.885, 95% CI: 0.81–0.96) and for the presence of high grade varices (P≥II) (AUROC: 0.850, 95% CI: 0.754–0.94). Using the cut-off value of 19.2 kPa, the sensitivity of transient elastography was 85%, specificity was 87%, positive predictive value was 85%, negative predictive value was 87% and validity was 86% for the detection of varices. Liver stiffness values less than 19.2 kPa were highly predicitive for the absence of large (P≥II) varices (sensitivity, 95%; specificity, 70%; positive predictive value, 54%; negative predictive value, 97%). Conclusions: Transient elastography may help to screen patients who are at high risk of bearing large (P≥II) oesophageal varices which predict variceal bleeding and, therefore, need endoscopic screening. Lives stiffness values higher than 19.2 kPa indicate the need for oesophageal-gastro-bulboscopy, while liver stiffness values lower than 19.2 kPa make the presence of large oesophageal varices unlikely. Orv. Hetil., 2014, 155(7), 270–276.


1996 ◽  
Vol 75 (02) ◽  
pp. 242-245 ◽  
Author(s):  
Marie Magnusson ◽  
Bengt I Eriksson ◽  
Peter Kãlebo ◽  
Ramon Sivertsson

SummaryPatients undergoing orthopedic surgery are at high risk of developing deep vein thrombosis. One hundred and thirty-eight consecutive patients undergoing total hip replacement or hip fracture surgery were included in this study. They were surveilled with colour Doppler ultrasound (CDU) and bilateral ascending contrast phlebography. The prevalence of proximal and distal DVT in this study was 5.8% and 20.3% respectively.CDU has a satisfactory sensitivity in patients with symptomatic deep vein thrombosis, especially in the proximal region. These results could not be confirmed in the present study of asymptomatic patients. The sensitivity was 62.5% (95% confidence interval: C.I. 24-91%) and the specificity 99.6% (C.I. 98-100%) for proximal DVT; 53.6% (C.I. 34-73%) and 98% (C.I. 96-99%) respectively for distal thrombi. The overall sensitivity was 58.1% (C.I. 39-75%) and the specificity 98% (C.I. 96-99%). The positive predictive value was 83.3% (C.I. 36-99%) and 75% (C.I. 51-91%) for proximal and distal DVT respectively. The negative predictive value was 98.9% (C.I. 98-100%) and 94.9% (C.I. 92-98%) for proximal and distal DVT respectively. The results of this study showed that even with a highly specialised and experienced investigator the sensitivity of CDU was too low to make it suitable for screening purposes in a high risk surgical population.


1982 ◽  
Vol 47 (02) ◽  
pp. 141-144 ◽  
Author(s):  
H Bounameaux ◽  
B Krähenbühl ◽  
S Vukanovic

SummaryDoppler ultrasound flow examination, strain gauge plethysmography and contrast venography were performed in 160 lower limbs of 80 in-patients. Deep vein thrombosis (DVT) was suspected in 87 limbs. Using measurement of venous stop-flow pressure, the Doppler method had an overall sensitivity of 83%. By combined use of Doppler and Plethysmography, sensitivity was increased to 96%. Specificity was 62% and 51%, respectively. With a positive and a negative predictive value of 80% and 73%, respectively, the combination of both non-invasive methods cannot reliably replace venography in the diagnosis of DTV, although all (40/40) thromboses proximal to or involving the popliteal segment were detected by either Doppler and Plethysmography or both.After exclusion of 14 patients (18%) suffering from conditions known to alter the results of these non-invasive methods, the positive predictive value of abnormal findings in both Doppler and Plethysmography was increased to 94% for suspected limbs, whilst negative predictive value of both negative Doppler and Plethysmography was 90%, allowing the avoidance of venography in these patients.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Hui Zhu ◽  
Xiaoxiao Jin ◽  
Yuqing Xu ◽  
Weihua Zhang ◽  
Xiaodan Liu ◽  
...  

Abstract Background Non-invasive prenatal screening (NIPS) is widely used as the alternative choice for pregnant women at high-risk of fetal aneuploidy. However, whether NIPS has a good detective efficiency for pregnant women at advanced maternal age (AMA) has not been fully studied especially in Chinese women. Methods Twenty-nine thousand three hundred forty-three pregnant women at AMA with singleton pregnancy who received NIPS and followed-up were recruited. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), receiver operating characteristic (ROC) curves and the Youden Index for detecting fetal chromosomal aneuploidies were analyzed. The relationship between maternal age and common fetal chromosomal aneuploidy was observed. Results The sensitivity, specificity, PPV, NPV of NIPS for detecting fetal trisomy 21 were 99.11, 99.96, 90.98, and 100%, respectively. These same parameters for detecting fetal trisomy 18 were 100, 99.94, 67.92, and 100%, respectively. Finally, these parameters for detecting trisomy 13 were 100, 99.96, 27.78, and 100%, respectively. The prevalence of fetal trisomy 21 increased exponentially with maternal age. The high-risk percentage incidence rate of fetal trisomy 21 was significantly higher in the pregnant women at 37 years old or above than that in pregnant women at 35 to 37 years old. (Youden index = 37). Conclusion It is indicated that NIPS is an effective prenatal screening method for pregnant women at AMA.


2021 ◽  
Vol 4 (Supplement_1) ◽  
pp. 37-38
Author(s):  
A Zoughlami ◽  
J Serero ◽  
G Sebastiani ◽  
M Deschenes ◽  
P Wong ◽  
...  

Abstract Background Patients with compensated advanced chronic liver disease (cACLD) are at higher risk of developing complications from portal hypertension, including esophageal varices (EV). Baveno VI and expanded Baveno VI criteria, based on liver stiffness measurement (LSM) by transient elastography combined with platelet count, have been proposed to avoid unnecessary esophagogastroduodenoscopy (EGD) screening for large esophageal varices needing treatment (EVNT). This approach has not been validated in patients with chronic hepatitis B virus (HBV) infection, who have etiology-specific cut-off of LSM for liver fibrosis. Aims We aimed to validate the Baveno VI and expanded Baveno VI criteria for EVNT in HBV patients with cACLD. Methods We performed a retrospective analysis of HBV patients who underwent LSM in 2014–2020. Inclusion criteria were: a) diagnosis of cACLD, defined as LSM &gt;9 kPa; b) availability of EGD and platelets within 1 year of LSM. Baveno VI (LSM &lt;20 kPa and platelets &gt;150,000) and expanded Baveno VI criteria (LSM &lt;25 kPa and platelets &gt;110,000) were tested for EGD sparing. Diagnostic performance of these criteria against gold standard (EGD) was computed and compared to patients with hepatitis C virus (HCV) infection and nonalcoholic steatohepatitis (NASH) etiologies, where these criteria have been widely validated. In these patients, the threshold for cACLD definition was &gt;10 kPa. Results A total of 287 patients (mean age 56, 95% Child A) were included, comprising of 43 HBV (58% on antiviral therapy), 134 HCV and 110 NASH patients. The prevalence of any grade EV and EVNT was 25% and 8% in the whole cohort, with 19% and 5% in HBV patients, respectively. Table 1 reports diagnostic performance, spared EGD and missed EVNT according to non-invasive criteria and cACLD etiology. Both Baveno VI and expanded Baveno VI criteria performed well in patients with HBV-related cACLD. There was no significant difference on diagnostic performance of these non-invasive criteria across the cACLD etiologies. Conclusions These results support use of non-invasive criteria based on LSM and platelets to spare unnecessary EGD in patients with HBV and cACLD. Baveno VI and expanded Baveno VI criteria can improve resource utilization and avoid invasive testing in context of screening EGD for patients with HBV-related cACLD. Funding Agencies None


Sign in / Sign up

Export Citation Format

Share Document