scholarly journals Reinforced Concrete Slabs Strengthened with Lap-Spliced Carbon TRC System

Materials ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3340
Author(s):  
Hyeong-Yeol Kim ◽  
Young-Jun You ◽  
Gum-Sung Ryu

Construction with precast or prefabricated elements requires the connecting of structural joints. This study presents an accelerated construction method to strengthen reinforced concrete (RC) slab-type elements in flexure using precast lap-spliced textile-reinforced concrete (TRC) panels. The objectives of this study are to identify the tensile behavior of a TRC system with lap-spliced textile, and to experimentally validate the performance of the proposed connecting method by flexural failure test for the concrete slabs strengthened by TRC panels with lap-spliced textile. Twenty-one coupon specimens were tested in tension with two different matrix systems and three different lap splice lengths. The influence of the lap splice length and matrix properties on the tensile performance of the TRC system was significant. Five full-scale RC slabs were strengthened by the precast TRC panels with and without the lap splice, and was tested in flexure. The results of the failure test for the strengthened specimens showed that the ultimate load of the strengthened specimen with the TRC panel increased by a maximum of 24%, compared to that of the unstrengthened specimen. Moreover, the failure-tested specimens were re-strengthened by a new TRC panel system and tested again in flexure. The objective of the re-strengthening of the damaged RC slabs by the TRC panel is to investigate whether the yielded steel reinforcement can be replaced by the TRC panel. The initial cracking load and the stiffness of the re-strengthened specimens were significantly increased by re-strengthening.

2014 ◽  
Vol 501-504 ◽  
pp. 1048-1052 ◽  
Author(s):  
Xiao Jin Li ◽  
Yi Yan Lu ◽  
Na Li

A total of four two-way reinforced concrete slabs strengthened with three methods were tested. The four test specimens were one unstrengthened reinforced concrete slab (control), one slab strengthened with CFRP strips, one slab strengthened with steel sheets, and one slab strengthened with an innovative method of applying CFRP strips and steel sheets combination bonding to the tension face of the slab. The test results show the CFRP-Steel combination strengthened technique is a rapid and effective strengthening technique for two-way RC slab. The increase in ultimate capacities of CFRP-Steel combination strengthened slab is 221.1% over the control slab, 84.4% over the CFRP-strengthened slab, and 45.2% over the steel-strengthened slab. In addition, the CFRP-Steel combination strengthened slab exhibited superior ductility than the CFRP-strengthened slab.


Materials ◽  
2021 ◽  
Vol 14 (17) ◽  
pp. 5046
Author(s):  
Hyeong-Yeol Kim ◽  
Young-Jun You ◽  
Gum-Sung Ryu

A textile reinforced concrete (TRC) system has been widely used for repair and strengthening of deteriorated reinforced concrete (RC) structures. This paper proposes an accelerated on-site installation method of a TRC system by grouting to strengthen deteriorated RC structures. Four RC slabs were strengthened with one ply of carbon textile grid and 20 mm-thick cementitious grout. The TRC strengthened slab specimens were tested under flexure and the test results were compared with those of an unstrengthened specimen and theoretical solutions. Furthermore, the TRC strengthened specimens experienced longer plastic deformation after steel yield than the unstrengthened specimen. The TRC strengthened specimens exhibited many fine cracks and finally failed by rupture of the textile. Therefore, TRC system with the proposed installation method can effectively be used for strengthening of deteriorated RC structural elements. The theoretically computed steel yield and ultimate loads overestimate the test data by 11% and 5%, respectively.


2020 ◽  
pp. 136943322097814
Author(s):  
Xing-lang Fan ◽  
Sheng-jie Gu ◽  
Xi Wu ◽  
Jia-fei Jiang

Owing to their high strength-to-weight ratio, superior corrosion resistance, and convenience in manufacture, fiber-reinforced polymer (FRP) bars can be used as a good alternative to steel bars to solve the durability issue in reinforced concrete (RC) structures, especially for seawater sea-sand concrete. In this paper, a theoretical model for predicting the punching shear strength of FRP-RC slabs is developed. In this model, the punching shear strength is determined by the intersection of capacity and demanding curve of FRP-RC slabs. The capacity curve is employed based on critical shear crack theory, while the demand curve is derived with the help of a simplified tri-linear moment-curvature relationship. After the validity of the proposed model is verified with experimental data collected from the literature, the effects of concrete strength, loading area, FRP reinforcement ratio, and effective depth of concrete slabs are evaluated quantitatively.


Materials ◽  
2020 ◽  
Vol 13 (17) ◽  
pp. 3856
Author(s):  
Young-Jun You ◽  
Hyeong-Yeol Kim ◽  
Gum-Sung Ryu ◽  
Kyung-Taek Koh ◽  
Gi-Hong Ahn ◽  
...  

Textile reinforced concrete (TRC) has widely been used for strengthening work for deteriorated reinforced concrete (RC) structures. The structural strengthening often requires accelerated construction with the aid of precast or prefabricated elements. This study presents an innovative method to strengthen an RC slab-type element in flexure using a precast panel made of carbon TRC. A total of five RC slabs were fabricated to examine the flexural strengthening effect. Two of them were strengthened with the precast panel and grouting material and another set of two slabs was additionally strengthened by tensile steel reinforcement. The full-scale slab specimens were tested by a three-point bending test and the test results were compared with the theoretical solutions. The results revealed that the ultimate load of the specimens strengthened with the TRC panel increased by at least 1.5 times compared to that of the unstrengthened specimen. The application of the precast TRC panel and grouting material for the strengthening of a prototype RC structure verified its outstanding constructability.


2018 ◽  
Vol 11 (2) ◽  
pp. 255-278
Author(s):  
C. O. CAMPOS ◽  
L. M. TRAUTWEIN ◽  
R. B. GOMES ◽  
G. MELO

Abstract The current study presents the results of tests conducted in 5 reinforced concrete slabs (415 cm x 415 cm x 7 cm) in order to experimentally check the possibility of reinforcing their upper surface, as well as to assess the adhesion between the old and the reinforcing concrete layers in the slab. The main variables were the concrete and reinforcement strength deficiencies. Reference slab “L1” was tested until reaching the failure load, whereas the others were tested until reaching certain load limit, reinforced and retested until reaching the failure load. All slabs failed under bending. The strengthening increased the failure load by 30% in slabs reinforced at minimum reinforcement rate when they were compared to similar non-reinforced slabs, regardless of the original concrete strength. None of the tests conducted in the reinforced slabs showed detachments or evidence of adhesion loss between the old and reinforcing concretes.


2011 ◽  
Vol 90-93 ◽  
pp. 933-939 ◽  
Author(s):  
Qiu Ning Yang ◽  
Ming Jie Mao ◽  
Sumio Hamada

Several equations for punching shear strength of the reinforced concrete slab have been proposed in the world. These equations have their own factors affecting the strength. There are numerous test data for punching shear strength of RC slabs, which have been obtained by numerous researchers. A database with approximately 300 specimens has been structured through the present study. In the present study seven equations for punching shear strength are evaluated based on the database. CCES equation is also evaluated from the present database.


Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1437
Author(s):  
Hyeong-Yeol Kim ◽  
Young-Jun You ◽  
Gum-Sung Ryu ◽  
Gi-Hong Ahn ◽  
Kyung-Taek Koh

Although carbon textile reinforcement widely used to replace the steel reinforcing bars but the bonding strength of carbon textile is generally much smaller than that of common steel bars. This study examines the strengthening effect of concrete slab-type elements strengthened in flexure by carbon textile reinforcement according to the surface coating of textile and the amount of reinforcement. The effect of the surface coating of textile on the bond strength was evaluated through a direct pullout test with four different sizes of coating material. The surface coated specimens developed bond strength approximately twice that of the uncoated specimen. The flexural strengthening effect with respect to the amount of reinforcement was investigated by a series of flexural failure tests on full-scale reinforced concrete (RC) slab specimens strengthened by textile reinforced concrete (TRC) system. The flexural failure test results revealed that the TRC system-strengthened specimens develop load-carrying capacity that is improved to at least 150% compared to the non-strengthened specimen. The strengthening performance was not significantly influenced by the textile coating and was not proportional to the amount of reinforcement when this amount was increased, owing to the change in the failure mode. The outstanding constructability afforded by TRC strengthening was verified through field applications executing TRC strengthening by shotcreting on a concrete box culvert.


2021 ◽  
Vol 7 (6) ◽  
pp. 1084-1097
Author(s):  
Dang Quang Ngo ◽  
Huy Cuong Nguyen

Nowadays, concrete is mostly prestressed with steel. But the application of prestressing steel is restricted in a highly corrosive environment area due to corrosion of prestressing steel, leading to a reduction in strength and may cause sudden failure. Carbon textile is considered an alternate material due to its corrosive resistance property, high tensile strength, and perfectly elastic. Prestressing is also the only realistic way to utilize fully ultra-high tensile strength in carbon textile material. In this study, experimental and numerical analyses were carried out for the flexural behaviour of prestressed and non-prestressed carbon textile reinforced concrete slabs. This study also focuses on the influences of textile reinforcement ratios, prestressing grades on the flexural behaviour of carbon textile reinforced concrete (TRC). Fifteen precast TRC slabs were tested, of which six were prestressed to various levels with carbon textile. The obtained results show that prestressing textile reinforcement results in a higher load-bearing capacity, stiffness, and crack resistance for TRC slabs. The first-crack load of the prestressed specimens increased by about 85% compared with those of non-prestressed slabs. Three-dimensional finite element models were developed to provide a reliable estimation of global and local response. The modeling techniques accurately reproduced the experimental behaviour. Doi: 10.28991/cej-2021-03091712 Full Text: PDF


Sign in / Sign up

Export Citation Format

Share Document