scholarly journals Shaping Ability, Cyclic Fatigue Resistance and Fractographic Analysis of Hybrid and Reciprocating Nickel Titanium Endodontic Instruments

Metals ◽  
2020 ◽  
Vol 10 (2) ◽  
pp. 172 ◽  
Author(s):  
Saulius Drukteinis ◽  
Vytaute Peciuliene ◽  
Ruta Bendinskaite ◽  
Vilma Brukiene ◽  
Rasmute Maneliene ◽  
...  

The aim of this study was to investigate the shaping ability and cyclic fatigue resistance of Genius (GN) and WaveOne (WO) nickel-titanium (NiTi) instruments. Forty mesial root canals of mandibular molars were randomly divided into two groups, according to the instrument system used for root canal preparation (n = 20): GN and WO. Root canals were prepared to the full working length using the crown-down technique, with up to 40.04 instruments for GN group and 40.08 instruments for WO group. Specimens were scanned with a µCT before and after instrumentation. The changes in 3D parameters and degree of canal transportation were evaluated in the apical, middle and coronal thirds of root canals. Size 25, taper 0.04 (GN) and 0.08 (WO) instruments (n = 20) were used in simulated root canals until fracturing, and the number of cycles to failure (NCF) was recorded. The fractured files were investigated under a scanning electron microscope to characterize fractured surfaces. Data were analyzed using ANOVA post hoc Tuckey’s tests with the significance level set at 5%. The GN system was able to prepare the higher percentage of the canal surface with less canal transportation in all root canal thirds and displayed the higher resistance to cyclic fatigue in comparison to WO instruments (p < 0.05). However, the length of the fractured segments was not significantly different among the groups; meanwhile, SEM investigations revealed the typical topographic characteristics of fractured surfaces. Hybrid GN instruments demonstrated superior shaping ability and resistance to cyclic fatigue. However, both NiTi instrument systems prepared the root canals with no significant shaping errors, considerable changes in 3D parameters and no significant differences in the topographic appearances of the instrument surfaces after fractures.

Materials ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 5823
Author(s):  
Saulius Drukteinis ◽  
Vytaute Peciuliene ◽  
Ruta Bendinskaite ◽  
Vilma Brukiene ◽  
Rasmute Maneliene ◽  
...  

The better understanding of the clinically important behavioral features of new instrument systems has an important significance for the clinical endodontics. This study aimed to investigate the shaping and centering ability as well as cyclic fatigue resistance of HyFlex CM (CM), HyFlex EDM (EDM) and EdgeFile (EF) thermally treated nickel–titanium (NiTi) endodontic instrument systems. Sixty curved root canals of the mesial roots of mandibular molars were randomly assigned into three groups (n = 20) and shaped using CM, EDM and EF files up to the size 40 and taper 04 of the instruments. µCT scanning of the specimens before and after preparation was performed and the morphometric 2D and 3D parameters were evaluated in the apical, middle and coronal thirds of root canals. In each group, 40.04 instruments (n = 20) were subjected to the cyclic fatigue resistance test in artificial root canals at 37 °C temperature until fractures occurred, and the number of cycles to failure (NCF) was calculated. The fractographic analysis was performed using a scanning electron microscope, evaluating topographic features and surface profiles of the separated instruments. The one-way analysis of variance with post hoc Tuckey’s test was used for statistical analysis of the data; the significance level was set at 5%. All systems prepared the comparable percentage of root canal surface with the similar magnitude of canal transportation in all root thirds (p > 0.05), but demonstrated significantly different resistance to cyclic fatigue (p < 0.05). The most resistant to fracture was EF, followed by EDM and CM. The length of the fractured fragments was not significantly different between the groups, and fractographic analysis by SEM detected the typical topographic features of separated thermally treated NiTi instrument surfaces.


Author(s):  
Jader Camilo Pinto ◽  
Fernanda Ferrari Esteves Torres ◽  
Airton Oliveira Santos-Junior ◽  
Marco Antonio Hungaro Duarte ◽  
Juliane Maria Guerreiro-Tanomaru ◽  
...  

Abstract Objective The aim of this study was to investigate the effect of additional apical preparation using the ProDesign Logic (PDL) 50/.01 rotary heat-treated nickel–titanium (NiTi) file with a larger diameter and minimal taper for retreatment of curved root canals. Materials and Methods Mesial curved root canals of 12 mandibular molars were prepared using PDL 25/.06 and filled using the continuous wave of condensation technique and AH Plus sealer. After retreatment using ProDesign S (PDS) 25/.08, PDL 25/.06 and PDL 35/05, a complementary procedure was performed with PDL 50/.01. Microcomputed tomography (micro-CT) scanning was performed before and after retreatment procedures. The cyclic fatigue resistance of unused PDS 25/.08, PDL 25/.06, PDL 35/.05 and PDL 50/.01 instruments (n = 12) was evaluated in a stainless-steel device. Statistical Analysis Data on the volumes of the root canals and the remaining filling materials were submitted to the paired t-test. Cyclic fatigue resistance data was submitted to one-way ANOVA and Tukey’s tests (α = 0.05). Results Use of PDL 50/.01 decreased the remaining filling materials in the apical third (p < 0.05). The root canal volume was similar in the cervical and middle thirds before and after preparation using PDL 50/.01 (p > 0.05). PDL 50/.01 presented the highest cyclic fatigue resistance (p < 0.05). Conclusions Use of the PDL 50/.01 instrument as an additional apical preparation for retreatment of curved root canals improved filling material removal in the apical third, while maintaining the dentin in the cervical and middle thirds. In addition, PDL 50/.01 presented high-flexural resistance.


2021 ◽  
Vol 6 (2) ◽  
pp. 101-105
Author(s):  
Kadam Krutika Kiran ◽  
Vagarali Hemant ◽  
Pujar Madhu A ◽  
Tamase Aishwarya S ◽  
Sahana Umesh

This study aimed to compare the canal transportation and canal centering ability in the preparation of curved root canals after instrumentation with TruNatomy (TN) (TN; Dentsply Sirona, Maillefer, Ballaigues, Switzerland) and ProTaper Gold (PG) (PG; Dentsply, Tulsa Dental Specialties, Tulsa, OK, USA) files using cone‑beam computed tomography (CBCT). 30 Single rooted extracted human teeth with root curvature ranging from 20-30° according to Schneider’s method were selected. Teeth with any visible cracks or fractures, calcifications, previous root canal treatments were excluded. The teeth were randomly assigned into two groups i.e. Group 1-TN and Group 2-PG (n = 15 each). The teeth were instrumented according to manufacturer’s guidelines for both the groups. Canals were scanned using a CBCT scanner before and after preparation to evaluate the transportation and centering ratio at 3 mm, 5 mm, and 7 mm from the apex. The data analysis was done using SPSS software and the test used was independent sample t test for comparison between the 2 groups.Data obtained suggested that TN group presented lesser canal transportation at the middle third of the root. The PG group showed better centering abitily at apical third of the root canal when both the groups were compared. TN resulted in less transportation than PG at the middle third, and PG showed better centering ability at the apical third. Overall, both systems safely prepared root canals, causing minimal errors.


2014 ◽  
Vol 15 (2) ◽  
pp. 174-180 ◽  
Author(s):  
Dina Al-Sudani ◽  
Majed Almalki ◽  
Saad Al-Shahrani ◽  
Michael Ahlquist

ABSTRACT Aim The present study was conducted with the aim of evaluating and comparing the shaping ability of two Nickel-titanium rotary instruments, with two disparate design features, on root canal geometry of extracted human maxillary first premolars using microcomputed tomography. Study design Twenty four bifurcated maxillary first premolars were divided into two groups and embedded in a rubber-based impression material. Both groups were submitted to microcomputed tomography before and after canal preparation (buccal and palatal) with either ProFile Vortex or Revo-S rotary instruments. Images were reconstructed and cross-sections corresponding to a distance 1, 2, 3, 4, 5, 6, and 7 mm from the anatomical apex were selected for canal transportation analysis. Volume changes were also measured. Results The degree and direction of canal transportation were non-significant for both instruments. Statistically significant differences were observed only between levels in the buccal canal in both groups. There was no significant difference between the two rotary systems in regards to the volume of dentin removed. Conclusion Our findings showed that ProFile Vortex and Revo-S instruments respected the original root canal anatomy and behaved similarly. ProFile Vortex rotary systems produced with innovative process were concluded to shape the upper maxillary premolar by leading minimal canal transportation, similar to Revo-S, rotary systems produced from traditional process. How to cite this article Al-Sudani D, Almalki M, Al-Shahrani S, Ahlquist M. Geometric Analysis of Maxillary First Premolar Prepared by Two Nickel-Titanium Rotary Instruments. J Contemp Dent Pract 2014;15(2):174-180.


2015 ◽  
Vol 16 (12) ◽  
pp. 927-932 ◽  
Author(s):  
Ranya F Elemam ◽  
JA Capelas ◽  
Mário AP Vaz ◽  
Nuno Viriato ◽  
ML Pereira ◽  
...  

ABSTRACT Aim To evaluate the frequent use of ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland) systems on shaping ability of root canal utilizing Solidworks (2014, Dassault Systèmes) software. Materials and methods Thirty-six root canals in clear resin blocks (Dentsply-Maillefer) were allocated into six experimental groups (n = 36). Six new sets of PTN instruments (Dentsply Maillefer, Ballaigues, Switzerland) were used six times to shape the resin blocks. A #15 K-file was inserted to the working length (WL), followed by ProGlider (PG) to create a glide path. Sequential use of PTN instrumentation in a crown-down technique was used to reach size (30/07) apically. Macroscopic photos of the blocks were taken before and after instrumentation, layered by Paint Shop Pro 9 from JascSoftware®, and then canal transportation was measured using Solidwork 2014. The data were analyzed by SPSS software version 22. Multivariate statistical analysis general linear model (GLM) was also applied. Bonferroni correction test was used in multiple comparisons and the statistical significance was set to 0.05. Results There was no difference in canal transportation resulted from utilizing PTN files after six multiple uses; in addition, the PTN files showed ability to maintain the original canal anatomy, especially in the apical level, where lowest total mean value of canal center displacement was seen (3 mm level) (0.019 ± 0.017). Conclusion ProTaper Next files can be used to prepare single and multiple canals in a single furcated tooth. Clinical significance ProTaper Next nickel-titanium (NiTi) file system is a safe instrument that respects the canal shape, allows practitioners to treat difficult cases with good results, and low risk of separation. How to cite this article Elemam RF, Capelas JA, Vaz MAP, Viriato N, Pereira ML, Azevedo A, West J. Evaluating Transportation by Comparing Several uses of Rotary Endodontic Files. J Contemp Dent Pract 2015;16(12):927-932.


2018 ◽  
Vol 47 (1) ◽  
pp. 325-334 ◽  
Author(s):  
Zhuwei Huang ◽  
Jingjing Quan ◽  
Jia Liu ◽  
Wen Zhang ◽  
Xiaolei Zhang ◽  
...  

Objective To evaluate the shaping ability of three thermally-treated rotary nickel-titanium (NiTi) systems including ProTaper Next (PTN), HyFlex™ CM (HFCM) and HyFlex™ EDM (HFEDM) during root canal preparation in simulated root canals. Methods A total of 45 simulated root canals were divided into three groups ( n = 15) and prepared with PTN, HFCM or HFEDM files up to size 25. Microcomputed tomography (microCT) was used to scan the specimens before and after instrumentation. Volume and diameter changes, transportations and centring ratios at 11 levels of the simulated root canals were measured and compared. Results HFEDM caused significantly greater volume increases than HFCM and PTN in the entire root canal and in the apical and middle thirds. HFCM removed the least amount of resin in the coronal third compared with HFEDM and PTN. Overall, HFCM caused significantly less transportation in the apical 2 mm and was better centred than PTN in the apical 3 mm. Conclusion Under the conditions of this study, all systems prepared curved canals without significant shaping errors and instrument fracture. PTN and HFCM cut less resin than HFEDM. HFCM stayed centred apically and cut the least material coronally.


2018 ◽  
Vol 12 (1) ◽  
pp. 32-45 ◽  
Author(s):  
Iussif Mamede-Neto ◽  
Álvaro Henrique Borges ◽  
Ana Helena Gonçalves Alencar ◽  
Marco Antonio Hungaro Duarte ◽  
Manoel Damião Sousa Neto ◽  
...  

Objective: To evaluate transportation (T) and centering ability (CA) of root canal preparations using continuous or reciprocating nickel-titanium endodontic files. Materials and Methods: Ninety-six mesiobuccal root canals of mandibular first and second molars were randomly divided into 6 groups (n=16) according to the rotary file used: 1. ProTaper Next; 2. ProTaper Gold; 3. Mtwo; 4. BioRaCe; 5. WaveOne Gold; 6. Reciproc. Root canals were prepared according to manufacturer’s instructions. Cone beam computed tomography scans were obtained before and after root canal preparation. Measurements were made at six different reference points: 2, 3 and 4 mm from the apex and 2, 3 and 4 mm below furcation in different directions. Results: The greatest Mesiodistal (MD) Transportation (T) was found for Reciproc files (p<0.05), and the greatest buccolingual (BL) T, for Reciproc, ProTaper Gold and ProTaper Next files (p<0.05). The greatest Mesiodistal (MD) Centering Ability (CA) was found for BioRaCe files (p<0.05), and the greatest Buccolingual (BL) CA, for BioRaCe and Mtwo files (p<0.05). Conclusion: All systems produced root canal transportation. No file system achieved perfect CA of root preparation. Reciproc files had the greatest MD T and BL T. BioRaCe files had the greatest MD CA, whereas BL CA was similar for BioRaCe and Mtwo files.


2021 ◽  
Author(s):  
Xixiong Chen ◽  
Jiuyu Ge

Abstract Background: The aim of this study was to compare the shaping ability of Gentlefile (GF), a unique stainless-steel (SS) rotary system, and ProTaper (PT), a popular mechanical nickel-titanium (NiTi) system, in J-shaped simulated canals. Methods: Thirty-three resin blocks with a J-shaped canal were selected and randomly divided into 3 groups according to tip diameters: GF red (#23); PT F2(#25); GF blue (#26). They were prepared in one training model which imitated human dentition. Specimens were photographed by a dental operating microscope before and after preparation. The images were processed and measured using professional software. Centering ability and canal transportation were calculated, canal aberration and instrument separation were also recorded. Results: The GF system was significantly less transported than PT F2 in the apical and middle section. What’s more, better centering ability of GF was shown in all sections, including the coronal level. However, there was no difference between GF red and GF blue based on above criteria. Two cases of instrument separation of GF were noted.Conclusion: Under the conditions of this study, the two GF files showed better shaping ability, but were more easily separated than PT F2. As a novel SS rotary system, Gentlefile is more flexible to prepare narrow and curved root canals by scraping dentin with high-speed rotation, which might help remove smear layer much thoroughly and cause less dentin microcracks.


2014 ◽  
Vol 15 (4) ◽  
pp. 451-455 ◽  
Author(s):  
Dina Al-Sudani ◽  
Hassan Kaabi ◽  
Abdulrahman Al Gamdi ◽  
Abdulla Al Dakheel

ABSTRACT Purpose The purpose of the present study was to investigate and compare the effect of different reciprocating movements and angles on the shaping ability of the WaveOne and the single-file ProTaper F2 using cone beam computed tomography (CBCT). Materials and methods The mesiobuccal canals of 40 extracted maxillary molars, with curvatures of 20 to 45° were coded and randomly divided into 4 equal experimental groups according to the instrument used (ProTaper F2 file and WaveOne) and the reciprocation range, for both instruments, a 150° angle was used for cutting and a 30° angle was used for release. Group 1 — WaveOne primary 150° CCW rotation angle and 30° CW rotation angle; Group 2 — WaveOne 90° CCW rotation angle and 30° CW rotation angle; Group 3 — ProTaper F2 150° CW rotation angle and 30° CCW rotation angle; Group 4 — ProTaper F2 90° CW rotation angle and 30° CCW rotation angle. Canals were scanned before and after preparation using CBCT to evaluate the volumetric change, canal transportation and the canal centering ability at 2.6, 5.2 and 7.8 mm from the apex. The mean ± standard deviation (SD) values were analyzed, and the significance level was set at p≤ 0.05 Results There was no significant difference in the amount of dentin removed among the experimental groups, except that WaveOne 150°CCW 30°CW significantly showed the least volume of dentin removed (0.40 ± 0.9) at 7.8 mm. All rotary systems tested in the different groups resulted in canal transportation in different directions at all examined levels. WaveOne 150°CCW 30°CW, demonstrated the lowest mean value of root canal transportation in both the mesial and furcal directions and in both the coronal and apical directions compared to the other groups. At the 7.8 level, WaveOne 150°CCW 30°CW yielded the highest mean centering ratio, whereas ProTaper F2 CW 150° CCW 30° yielded the lowest, statistically significant at p≤ 0.05 Conclusion The results of the present study demonstrated that differences among various reciprocating motions and angles could affect the shaping ability of a single-file Nickel-titanium (NiTi) instrument. How to cite this article Al-Sudani D, Kaabi H, Gamdi AA, Dakheel AA. The Influence of Different Angles and Reciprocation on the Shaping Ability of Two Nickel-Titanium Rotary Root Canal Instruments. J Contemp Dent Pract 2014;15(4):451-455.


Materials ◽  
2020 ◽  
Vol 13 (21) ◽  
pp. 4914
Author(s):  
Young-Ryul Oh ◽  
Hye-Min Ku ◽  
Dohyun Kim ◽  
Su-Jung Shin ◽  
Il-Young Jung

This study evaluated the effectiveness of NiTi ultrasonic tips for Enterococcus faecalis (E. faecalis) biofilm removal in simulated complex root canals. Sixty root canal models consisting of a 30-degree curved main canal and two lateral canals were constructed from polydimethylsiloxane and incubated with E. faecalis. Irrigants in root canals were activated using a manual syringe (SI), a stainless steel (SS) instrument, a nickel-titanium (Ni-Ti) ultrasonic instrument, or a sonic instrument (EA). Instruments of SI, SS, and NiTi-9 groups were placed 9 mm from the apex, whereas those in NiTi-2 and EA groups were placed 2 mm from the apex. The efficacy of each method was determined as the ratio of fluorescence concentration before and after activation. In the apical curved canal, the highest efficacy was found in the NiTi-2 group (99.40%), followed by SI (84.25%), EA (80.38%), SS (76.93%), and NiTi-9 (67.29%) groups. In lateral canals 1 and 2, the efficacy was the highest in the NiTi-2 group and the lowest in the SI group. The NiTi ultrasonic instrument could effectively remove biofilms in the curved canal and lateral canals. This instrument should be introduced close to the working length. An up-and-down motion of the activation instrument is recommended.


Sign in / Sign up

Export Citation Format

Share Document