scholarly journals Development of a Multiplex Droplet Digital PCR Assay for the Detection of Babesia, Bartonella, and Borrelia Species

Pathogens ◽  
2021 ◽  
Vol 10 (11) ◽  
pp. 1462
Author(s):  
Ricardo Maggi ◽  
Edward B. Breitschwerdt ◽  
Barbara Qurollo ◽  
Jennifer C. Miller

We describe the development, optimization, and validation of a multiplex droplet digital PCR (ddPCR) assay for the simultaneous detection of Babesia, Bartonella, and Borrelia spp. DNA from several sample matrices, including clinical blood samples from animals and humans, vectors, in-vitro infected human and animal cell lines, and tissues obtained from animal models (infected with Bartonella and/or B. burgdorferi). The multiplex ddPCR assay was able to detect 31 Bartonella, 13 Borrelia, and 24 Babesia species, including Theileria equi, T. cervi, and Cytauxzoon felis. No amplification of Treponema or Leptospira spp. was observed. Sensitivity of 0.2–5 genome equivalent DNA copies per microliter was achieved for different members of the Bartonella and Borrelia genus, depending on the species or matrix type (water or spiked blood DNA) tested. The ddPCR assay facilitated the simultaneous detection of co-infections with two and three vector-borne pathogens comprising four different genera (Babesia, Bartonella, Borrelia, and Theileria) from clinical and other sample sources.

2018 ◽  
Vol 164 (3) ◽  
pp. 691-697 ◽  
Author(s):  
Yingjie Liu ◽  
Yingli Wang ◽  
Qin Wang ◽  
Yanhui Zhang ◽  
Wanxia Shen ◽  
...  

2019 ◽  
Vol 235 (3) ◽  
pp. 1888-1894 ◽  
Author(s):  
Andrea Tagliapietra ◽  
John Charles Rotondo ◽  
Ilaria Bononi ◽  
Elisa Mazzoni ◽  
Federica Magagnoli ◽  
...  

Blood ◽  
2015 ◽  
Vol 126 (23) ◽  
pp. 2784-2784
Author(s):  
Jaspal Kaeda ◽  
Simone Bonecker ◽  
Frauke Ringel ◽  
Michaela Schwarz ◽  
Bernd Dörken ◽  
...  

Abstract Data show 40% of chronic myeloid leukemia (CML) patients maintain complete molecular remission (CMR), i.e. failure to detect BCR-ABL1, consenting to termination of Imatinib mesylate (IM) therapy, following undetectable disease for ≥2 years by quantitative PCR (Q-PCR). These findings suggest majority of the patients experience molecular relapse. Furthermore, majority relapse in the first 6 months, implying Q-PCR assay sensitivity is suboptimum, to confidently identify patients for discontinuation of IM. Droplet digital PCR (ddPCR) is suggested to have sensitivity that is one log greater than the Taqman (Q-PCR) assay. If verified, ddPCR would enhance safe withdrawal of IM therapy from CML patients. Here we present data comparing ddPCR with Q-PCR. In total we assayed 161 samples, of these 6 were serial dilutions of the International reference (IR) BCR-ABL1 plasmid, the remainder were cDNA samples. The 161 samples comprised of 4 sample groups; I: CML chronic phase samples (n=118); II: CML samples post stem cell transplant (SCT) (n=22); III: normal control (NC) samples (n=16); IV: Serially diluted BCR-ABL1 1.04x10e2 copies/µl, IR ERM-AD623e (n=6). Group I comprised of 121 samples from 21 CML patients in chronic phase treated with IM. Group II comprised of 21 samples from 19 CML patients (2 samples each for 2 of these 19 patients) who had undergone SCT. Group II comprised of samples from normal adult blood donor volunteers. Finally, Group IV included 6 serially diluted samples, ranging 100 to 0.001 copies of the IR (1.04x10e2 copies/µl) plasmid (Sigma, Munich, Germany). All the Group I, III and IV samples were subjected to Q-PCR Taqman assay and ddPCR (Biorad, California, USA). The Group III samples were in addition subjected to nested PCR. Only those samples with cycle threshold (Ct) <37 in 2 or more replicates by Q-PCR were recorded positive. For ddPCR those samples with sum of ≥3 positive droplets with a minimum 5500 droplets per well were reported positive. All the PCR reactions were performed in triplicate in final volume of 20µl, which included 5µl of cDNA or reference plasmid. Among Group I, Q-PCR detected BCR-ABL1 in 57 of the 118 patient samples assayed, with a median of 16.72 transcripts (range 1.38-47450). In only 2 (2.25 and 4.96 transcripts) of these 57 samples, ddPCR failed to detect BCR-ABL1 transcripts. Q-PCR and ddPCR failed to detect BCR-ABL1 in 45 (38.1%) samples. For 14 (11.8%) of the samples ddPCR was positive, median 3.4 copies (range 3-15) but negative by Q-PCR. Among Group II, one of the 21 samples was excluded from the analysis because <5500 droplets were generated. Of the 21 samples 7 were negative by ddPCR. Nested PCR was negative for all 7 samples. Three samples were positive by all 3 technologies, nested PCR, Q-PCR and ddPCR. Remarkably, 5 of the 21 samples were negative by nested, but positive by ddPCR; median 18.0 copies (6.2-22.0). These 5 samples were not subjected to Q-PCR. In Group III all 16 NC samples were negative by Q-PCR and ddPCR. In Group IV, ddPCR did detect BCR-ABL1 in the serially diluted IR sample calculated to have 1 copy (26 positive droplets of the 106095 total droplets), but Q-PCR failed. However, the lower dilutions, calculated to contain 0.1, 0.01 and 0.001 copies were negative by ddPCR and Q-PCR. We assayed 161 samples by ddPCR and Q-PCR, of these 139 were from CML patients. In addition 21 of the samples were also subjected to nested PCR. Our data support the notion ddPCR is at least one log more sensitive than Q-PCR. Of the 140 patient samples assayed, 19 (13.5%) were positive by ddPCR but negative by Q-PCR. Only 2 of the 118 samples in Group I were negative by ddPCR but positive by Q-PCR. There was in insufficient sample to repeat these 2 assays. The increased sensitivity of ddPCR as implied by the clinical samples was supported by assays performed using the IR. The serial dilution equivalent to 1.0 BCR-ABL1 copy was reliably detected by ddPCR, but was negative by Q-PCR. In summary, these data suggest ddPCR is more sensitive. However, the clinical significance of this must be assessed in context of long-term clinical outcome of patients with detectable BCR-ABL1 by ddPCR and negative by Q-PCR. But, clearly increased sensitivity is likely to enhance safe withdrawal of IM therapy for CML patients in CMR. Furthermore, regular monitoring of these patients by ddPCR would enable early detection of molecular relapse and thereby minimize the risk of disease progression. Disclosures Le Coutre: Novartis: Honoraria.


PLoS ONE ◽  
2018 ◽  
Vol 13 (5) ◽  
pp. e0197184 ◽  
Author(s):  
Vijayanandraj Selvaraj ◽  
Yogita Maheshwari ◽  
Subhas Hajeri ◽  
Jianchi Chen ◽  
Thomas Greg McCollum ◽  
...  

2016 ◽  
Vol 64 (2) ◽  
pp. S354
Author(s):  
A. Olivero ◽  
M.L. Abate ◽  
G. Niro ◽  
G.P. Caviglia ◽  
C. Rosso ◽  
...  

2021 ◽  
pp. 100-103
Author(s):  
A.V. Blagodatova ◽  
◽  
K.V. Kochkina ◽  
M.A. Komarova ◽  
N.Y. Trofina ◽  
...  

The aim of the research. To obtain aptamers-inhibitors of platelet glycoprotein IIb / IIIa receptors, blocking platelet aggregation. Material and methods. Th e selection of aptamers for IIb / IIIa receptors of platelets was carried out according to the SELEX method (Systematic Evolution of Ligands by Exponential Enrichment), modifi ed to select aptamers for a specifi c epitope. Th e method allows selection and in vitro evolution of aptamers with selectivity to a specifi c target from a large library of oligonucleotides. Th e affi nity of aptamers for platelet IIb / IIIa receptors was determined using fl ow cytometry. Results. Pools of aptamers of aptamers with high affi nity for IIb / IIIa platelet receptors were obtained. Th e study of the antiaggregation properties of the pools with the best binding showed that platelet aggregation was minimal when using the aptamers from the pool of the 5th round of selection. Th us, the aptamers of this pool have the greatest potential to be used as an analogue of a synthetic peptide that blocks thromboaggregation. Aptamers from this pool were taken for sequencing in order to obtain sequences of aptamers with the best antiaggregatory properties. Conclusion. Pools of aptamers with high affi nity for IIb / IIIa receptors of platelets and anticoagulant activity were obtained.


2021 ◽  
Author(s):  
Fanfeng Meng ◽  
Zhihao Ren ◽  
Yixin Wang ◽  
Peng Zhao ◽  
Guozhong Zhang

Abstract Background: The use of Reticuloendotheliosis virus (REV) from contaminated live virus vaccine is suspected to be one of the most important causes of massive outbreaks of Reticuloendotheliosis in China. Methods: In this study, we established a droplet digital PCR (ddPCR) detection method for REV and compared its sensitivity to different methods to detect REV contamination in a vaccine. Results: The results indicated that both quantitative PCR and dot-blot methods could detect REV contamination at a dose of 1 TCID50/1,000 feathers, whereas ddPCR could detect REV contamination at a dose of 0.1 TCID50/1,000 feathers, which is 1,000-fold more sensitive than conventional polymerase chain reaction detection (102 TCID50/1000 feathers). ddPCR not only exhibited the highest sensitivity but also proved extremely intuitive, especially to detect REV contamination in vaccines.Conclusions: The ddPCR method established in this study to detect REV contamination in vaccines can effectively detect and quantify low-dose REV contamination. This provides a new method for the rapid detection of REV contamination in various samples, especially vaccines.


Sign in / Sign up

Export Citation Format

Share Document